Solution Type Technical Instruction Sure Solution 1014682.1 : SL8500 - Exerciser Routine for Libraries Using SL Console with SLC Code 2.40 and Above
PreviouslyPublishedAs 221802 Oracle Confidential PARTNER - Available to partners (SUN). Reason: Confidential for Partners and Oracle Support personnel Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms GoalExerciser routine for libraries using SL Console. SolutionSteps to Follow
This version offers you an advantage in that it can run tests for an entire rail - there is no need to run two sequences to include opposite sides of the library. It will run to all slots with the "minimum/maximum" test configuration. In addition, version 2.40 "knows" that inner columns -3 through -8, and +3 through +8 do not exist; therefore there is no need for special entries for these locations. Regarding the 2.40 (2.23.00) version of StreamLine Library Console, the file enclosed is a generic exerciser routine that is contained in the FRS 2.40 operator panel. The enclosed file is suppliedto you for remote application. You can add these manually to the local operator panel after a code update. If you do not have an operator panel at this version, you must be aware of the following: If you download the 2.40 version to the operator panel, you will lose any test suites that you may have loaded on that operator panel. Youcan run the enclosed tests by simply downloading only the 2.40 PC (remote) version to your laptop; this method is described below. Before you start: 1) The storage slots tests runs optimally if half the storage slots contain tapes and the other half are empty. 2) You must have diagnostic cartridges installed in the reserved (system) slots to test elevator and CAP slots. 3) The library must be offline to ACSLS/HSC. 4) Be sure to run a Full (disruptive) self-test first (Tools >>> Diagnostics >>> Full) - this will perform an audit and supply you with any targeting errors that may occur. If there are targeting errors, the test displays "failed" and reports the errors. 5) Correct any errors you find. To load and initiate the enclosed file for remote testing: 1) Download the remote application of version 2.40 of StreamLine Library Console (available on the CRC). 2) After downloading, the following file structure is created for you: C:\Documents and Settings\your_user_id - (1st 5 letters of your last name + initials of your 1st and middle name)\SLConsole\config\library\SL8500\exerciser. 3) Copy the enclosed file and paste it into the exerciser folder. 4) Remotely log into a library through StreamLine Library Console. 5) Go to: Tools >>> Diagnostics >>> Manage 6) Click the Restore tab in the upper part of the screen. 7) Locate and select the enclosed file within the folder structure listed above. 8) The tests will appear in the lower window section. 9) Click each test suite that you want to run, then click Open 10) Click the Monitor tab. A new window will open. 11) Just above this new window, Click Window >>> Arrange. All test suites that you have selected will appear in individual windows. 12) To start each test suite, click File >>> Start Note: Drive tests are not included. You must enter the drive type/location and match it with a corresponding tape (in the reserved/system slots) for that drive.
Attachments This solution has no attachment |
||||||||||||
|