Asset ID: |
1-71-1014191.1 |
Update Date: | 2017-09-21 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1014191.1
:
C4 - How to Calibrate Camera in Library
Related Items |
- Sun Storage C4 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
PreviouslyPublishedAs
220552
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential information provided to Oracle and Partner Service Personnel
Applies to:
Sun Storage C4 Tape Library - Version Not Applicable and later
All Platforms
Goal
How to Calibrate Camera in C4 Library.
Solution
Steps to Follow:
Any time a hand/camera assembly is to be changed out for target calibration errors or when a new hand/camera assembly is placed into the C4 library, it is highly encouraged to run the Camera Calibration Routine to make sure the camera is lined up properly.
Download the attached Camera Calibration tool and instructions.
The camera is NOT a FRU. If the camera fails calibration, the whole robotic hand assembly must be replaced.
How to calibrate camera in library, How to avoid unnecessary camera replacement, PX500, Camera, Camera calibration procedure, Calibration tool, Internal target failure, Mode sense error, Critical event code C2502410, Initialization failure, C4, 4/44/00, Hand replacement
Previously Published As STKKB80136
Attachments
This solution has no attachment