![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1013760.1 : VSM - What Is The MIH Value For VTDs?
PreviouslyPublishedAs 219586 Applies to:Sun StorageTek Virtual Tape Control Software (VTCS) - Version 6.2 and laterSun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later Sun StorageTek VSM System - Version 4 and later IBM z/OS on System z GoalWhat is the MIH (Missing Interrupt Handler) value for VTDs? Solution1. For VTDs - The MIH value should be set for 20 minutes. D IOS,MIH,DEV=xxxx where xxxx is VTD address. Command to set the value is: SET IOS,MIH TIME=20:00,DEV=(xxxx-xxxx) 2. For RTDs - There is no need to set the MIH for RTDs. Attachments This solution has no attachment |
||||||||||||
|