Solution Type Technical Instruction Sure Solution 1013648.1 : SL3000/SL8500 - How to Reboot a Device or Component Using SL Console
PreviouslyPublishedAs 219254 Applies to:Sun StorageTek SL3000 Modular Library System - Version Not Applicable and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later All Platforms GoalHow to reboot a drive or component through SLConsole. SolutionReboot a device using SL Console. 1. Before doing anything, collect the error information and review the event logs. Refer to 1014228.1 if necessary. 2. From the SL Console Op Panel, go to Tools/Diagnostics. Expand the list to show the affected device (CAP, Drive, Elevator, Robot, or Library). 3. Attempt to Reboot the device by selecting the device and pressing the Reboot button. Libraries should only be Rebooted if the SL8500 (all four LSM's) are completely down/offline. Note: You cannot reboot the CAP in a SL3000 but you are able to with a SL8500. Attachments This solution has no attachment |
||||||||||||
|