Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1013648.1
Update Date:2017-08-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1013648.1 :   SL3000/SL8500 - How to Reboot a Device or Component Using SL Console  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  

PreviouslyPublishedAs
219254


Applies to:

Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
All Platforms

Goal

How to reboot a drive or component through SLConsole.

Solution

Reboot a device using SL Console.

1. Before doing anything, collect the error information and review the event logs.   Refer to 1014228.1 if necessary.

2. From the SL Console Op Panel, go to Tools/Diagnostics.  Expand the list to show the affected device (CAP, Drive, Elevator, Robot, or Library).

3. Attempt to Reboot the device by selecting the device and pressing the Reboot button.  Libraries should only be Rebooted if the SL8500 (all four LSM's) are completely down/offline.

Note:  You cannot reboot the CAP in a SL3000 but you are able to with a SL8500.


The CAP can be online /offline with below steps: