![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1012942.1 : Sun Fire[TM] X2100/X2200 M2 Server: PC Check displays DIMMs in incorrect slot numbers
PreviouslyPublishedAs 217738 Description When running PC Check on the Tools & Drivers CD and selecting memory tests from the advanced diagnostics menu, the DIMMs will be displayed as being in the wrong slots. Steps to Follow The DIMMs are installed in slot 0 and 1, but PC Check displayed DIMM7 and DIMM6. The relation between a number of DIMM slot and a number of PC Check is the following table. Sun Fire[TM] X2100 M2 Server
Sun Fire[TM] X2200 M2 Server
Internal Comments This symptom on X2200 M2 is CR#6475716. It will be fixed in a X2100 M2, X2200 M2, Leo, Taurus, M2, dimm, PC check, diag Previously Published As 87986 Version: 0 Product_uuid 421f3c0e-dae5-11da-a742-080020a9ed93|Sun Fire X2200 M2 Server 417b81fb-dae5-11da-a742-080020a9ed93|Sun Fire X2100 M2 Server Attachments This solution has no attachment |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|