Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1012942.1
Update Date:2016-11-03
Keywords:

Solution Type  Technical Instruction Sure

Solution  1012942.1 :   Sun Fire[TM] X2100/X2200 M2 Server: PC Check displays DIMMs in incorrect slot numbers  


Related Items
  • Sun Fire X2100 M2 Server
  •  
  • Sun Fire X2200 M2 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
217738


Description

When running PC Check on the  Tools & Drivers  CD and selecting memory tests from the advanced diagnostics menu, the DIMMs will be displayed as being in the wrong slots.



Steps to Follow

The DIMMs are installed in slot 0 and 1, but PC Check displayed DIMM7 and DIMM6. The relation between a number of DIMM slot and a number of PC Check is the following table.

Sun Fire[TM] X2100 M2 Server

DIMM slot#

Slot# on PC Check

0

DIMMA0, BANK2

1

DIMMB0, BANK3

2

DIMMA1, BANK0

3

DIMMB1, BANK1

Sun Fire[TM] X2200 M2 Server

CPU#

DIMM slot#

Slot# on PC Check

0

0

7

0

1

6

0

2

5

0

3

4

0

4

3

0

5

2

0

6

1

0

7

0

1

0

15

1

1

14

1

2

13

1

3

12

1

4

11

1

5

10

1

6

9

1

7

8



Internal Comments

This symptom on X2200 M2 is CR#6475716. It will be fixed in a
future release of PC Check. But a schedule is no plan at this
time.


X2100 M2, X2200 M2, Leo, Taurus, M2, dimm, PC check, diag
Previously Published As
87986

Version: 0
Product_uuid
421f3c0e-dae5-11da-a742-080020a9ed93|Sun Fire X2200 M2 Server
417b81fb-dae5-11da-a742-080020a9ed93|Sun Fire X2100 M2 Server

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.