![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1012388.1 : Sun Fire[TM] v1280, E2900, and Netra 1280, 1290: Lights Out Management (LOM) Quick Command Reference
PreviouslyPublishedAs 217087 Applies to:Sun Netra 1280 Server - Version Not Applicable to Not Applicable [Release N/A]Sun Fire V1280 Server - Version Not Applicable and later Sun Fire E2900 Server - Version Not Applicable and later All Platforms Goal
Solution
bootmode normal break - Send a break signal to the Solaris console.
console - Connect to the Solaris/OpenBoot PROM console.
disablecomponent - Add a component to the blacklist.
enablecomponent - Remove a component from the blacklist.
flashupdate - Update the flash PROMs in the System Controller, all the system boards, or a specified board number.
help - Without arguments, list all available LOM commands. When an argument is supplied, display basic usage of the specified command and a short description.
history - Display the command history along with date and time stamps.
inventory - Display SEPROM contents of a FRU.
logout - Log out from this connection.
password - Set the password for the LOM.
poweroff - Forcibly power off the whole system to standby, or a FRU, or a list of FRUs.
poweron - Power on the entire system, or a FRU, or a list of FRUs.
reset Reset the Solaris system .
resetsc - Reset the System Controller.
setalarm - Set the system alarm relays and associated LEDS.
setdate - Set the date and time for the system.
setescape - Set the sequence of characters used to switch from the Solaris or OpenBoot PROM console to the LOM prompt.
seteventreporting - The seteventreporting command controls which messages are printed at the LOM prompt and the level of logged messages sent to Solaris.
setlocator - Set the state of the system Locator LED.
setupnetwork - Set up System Controller network attributes.
setupsc - Configure optional System Controller features.
showalarm - Display state of system alarm relays and LEDs.
showboards - Display the status for all boards in the system
showcomponent - Display a component or a list of components.
showdate - Display the current date and time for the system.
showenvironment - Display the current environmental status, temperatures, voltages, fan status, and so on, for the system..
showescape - Display the current escape sequence.
showeventreporting - Display the settings applied to the LOM software event reporting and messages.
showfault - Display the state of the system Fault LED.
showhostname - Display the system hostname.
showlocator - Display the state of the system Locator LED.
showlogs - Display the message event log.
For systems configured with enhanced-memory SCs (SC V2s), the following command shows the system error contents maintained in the persistent buffer.
showmodel - Display the platform model.
shownetwork - Display System Controller (LOM) network settings and MAC addresses.
showresetstate - Display the CPU registers after an abnormal Solaris reset.
showsc - Display version and uptime information about the System Controller.
shutdown - Shut down Solaris and enter standby mode.
testboard - Test the specified CPU/Memory board.
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate
My Oracle Support Community - Oracle Sun Technologies Community.
Attachments This solution has no attachment |
||||||||||||
|