Solution Type Technical Instruction Sure Solution 1012305.1 : Sun Fire[TM] 12K/15K/20K/25K: DR attach/detach operations failing due to portid conflicts arising from third party device drivers
PreviouslyPublishedAs 216980 Applies to:Sun Fire 12K Server - Version Not Applicable and laterSun Fire 15K Server - Version Not Applicable and later Sun Fire E20K Server - Version Not Applicable to Not Applicable [Release N/A] Sun Fire E25K Server - Version Not Applicable to Not Applicable [Release N/A] Sun SPARC Sun OS GoalThe dynamic reconfiguration (DR) feature on the Sun Fire[TM] 12K/15K/20K/25K servers enables you to perform hardware configuration changes to a live domain that is running the Solaris[TM] Operating System without causing machine downtime. SolutionYou can execute DR operations from the system controller (SC) by using the SMS commands: addboard(1M), moveboard(1M),deleteboard(1M), and rcfgadm(1M). hgc-6-sc0% date;addboard -da sb0
assign SB0 ... assign SB0 done poweron SB0 .... poweron SB0 done test SB0 ......... test SB0 done connect SB0 ...... ERROR: Unable to configure SB0 into domain: A addboard: Hardware specific failure: connect SB0: Cannot read property value: Device Node 0x0: property name
Aug 16 06:22:48 aji drmach: [ID 801593 kern.warning] WARNING: Cannot read property value: Device Node 0x0: property name
Aug 16 06:22:48 aji dcs: [ID 903045 daemon.error] <718> config_change_state: Hardware specific failure: connect
xcat3-sc0:sms-svc:6> deleteboard SB0
request delete capacity (4 cpus) request delete capacity (524288 pages) request delete capacity SB0 done request offline SUNW_cpu/cpu0 request offline SUNW_cpu/cpu1 request offline SUNW_cpu/cpu2 request offline SUNW_cpu/cpu3 request offline SUNW_cpu/cpu0 done request offline SUNW_cpu/cpu1 done request offline SUNW_cpu/cpu2 done request offline SUNW_cpu/cpu3 done unconfigure SB0 unconfigure SB0 done notify remove SUNW_cpu/cpu0 notify remove SUNW_cpu/cpu1 notify remove SUNW_cpu/cpu2 notify remove SUNW_cpu/cpu3 notify remove SUNW_cpu/cpu0 done notify remove SUNW_cpu/cpu1 done notify remove SUNW_cpu/cpu2 done notify remove SUNW_cpu/cpu3 done disconnect SB0 ERROR: Unable to unassign SB0 from domain: A deleteboard: Hardware specific failure: disconnect SB0: Solaris failed to deprobe: SB0
Jul 21 23:30:57 nebula2 gptwocfg: [ID 200766 kern.notice] ndi_devi_offline failed
... Jul 21 23:30:57 nebula2 drmach: [ID 801593 kern.warning] WARNING: Cannot read property value: Device Node 0x0: property name Jul 21 23:30:57 nebula2 dcs: [ID 678942 daemon.error] <7858> config_change_state: Hardware specific failure: disconnect SB0: Solaris failed to deprobe: SB0
111335-27 = platform/SUNW,Sun-Fire-15000/kernel/misc/sparcv9/drmach
bug fixes are in patch 117124-05 which was integrated into 122300 Attachments This solution has no attachment |
||||||||||||
|