Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1012024.1
Update Date:2017-10-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1012024.1 :   Sun Storage 3510 and 3511 Arrays: How to Resolve SES and PLD Firmware Mismatches  


Related Items
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3510 FC Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: SE31xx_33xx_35xx
  •  

PreviouslyPublishedAs
216477


Applies to:

Sun Storage 3511 SATA Array - Version Not Applicable and later
Sun Storage 3510 FC Array - Version Not Applicable and later
All Platforms

Goal

This document describes how to resolve a SES or PLD firmware mismatch for a Sun Storage 3510 or 3511 Array.

SES is the SCSI Enclosure Services processor, which handles enclosure management functions. PLD is the Programmable Logic Device, which is responsible for routing fibre channel traffic within the array. In an array with dual controllers, both controllers must use the same SES and PLD versions to avoid issues.

The example below shows a mismatch (The Rev column shows the SES firmware revision):

sccli> show ses
Ch  Id  Chassis  Vendor  Product ID        Rev   PLD   WWPN
-----------------------------------------------------------------------
2 124           SUN     StorEdge 3510F A  1040  A000  204000C0FF000008
3 124           SUN     StorEdge 3510F A  1040  8B00*  204000C0FF000008

* Indicates SES or PLD firmware mismatch.

 

Solution

SES and PLD firmware must match on controllers, but every controller firmware version also expects specific corresponding firmware versions for each type of firmware. To resolve an SES or PLD firmware mismatch, Oracle recommends upgrading to the latest version of all firmware components like Controller, SES, PLD and also Disk.

To upgrade firmware for the Sun Storage 3510 array, download <Patch 113723-21> and follow the detailed instructions in the patch README.

To upgrade firmware for the Sun Storage 3511 array, download <Patch 113724-12> and follow the detailed instructions in the patch README. Note that the 3511 has several additional firmware components to maintain, as described in the patch README.

The example below shows the output of sccli>show ses command after the upgrading SES and PLD firmware revision to latest:

sccli> show ses
Ch  Id  Chassis   Vendor/Product ID           Rev  PLD  WWNN                    WWPN
------------------------------------------------------------------------------------------------------
 2  124 001XXX  SUN StorEdge 3510F A     1106 1000 204000C0FF000008 214000C0FF000008 Topology: loop(a)
 3  124 001XXX  SUN StorEdge 3510F A     1106 1000 204000C0FF000008 224000C0FF000008 Topology: loop(b)

 

In patches 113723-21 and 113724-12, the SES and PLD firmware upgrade requires upgrading controller firmware to version 4.23A.
To upgrade controller firmware from 3.2xx to 4.15x or later, special instructions must be followed which are given in Sun StorEdge 3000 Family RAID Controller Firmware Migration Guide.

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback