Solution Type  Technical Instruction Sure

Solution  1011474.1 :   Sun Storage 6140 Array Firmware Matrix  


Related Items
  • Sun Storage Common Array Manager (CAM)
  •  
  • Sun Storage 6140 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: 6140_6180
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
215716
This article documents Sun StorageTek 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

In this Document
Goal
Solution
References


Applies to:

Sun Storage Common Array Manager (CAM) - Version 5.0 and later
Sun Storage 6140 Array - Version Not Applicable and later
All Platforms

Goal

This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware and management software compatibility.

For instructions to download CAM, please refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches.

For instructions to upgrade from 6.xx to 7.xx firmware, please refer to <Document 1131593.1> Procedure to Upgrade the Sun StorageTek[TM] 6540 Array, 6140 Array or FLX380 Storage Array from Firmware 06.xx to 07.xx.

Solution

Baseline / CAM Release Sun Storage 6140 Array Firmware
Patch Controller Expansion
Firmware NVSRAM CSM100 FC CSM100 SATA CSM200 FLA200 FC FLA300 FC FLC200 dSATA FLC200 iSATA
1.0 no support
1.1
1.2
1.3
2.0 120337-03 06.16.73.10 N399X-616843-008 no support 9865 no support
2.1 120337-04 06.16.81.10 N399X-616843-010 9865
Naming convention changed. Version following 2.1 is 5.0. There was no 3.x or 4.x.  
5.0 120337-11 06.16.81.10 N399X-616843-010 9865
5.0.1 120337-11 06.16.81.10 N399X-616843-010 9865
5.0.2 120337-11 06.16.81.10 N399X-616843-010 9865
5.0.2 124946-01
118185-26
  9867a
5.1.0.10 120337-13 06.19.23.10b N399X-619843-004b 9643 9726 9884
5.1.0.11 120337-13 06.19.25.10c N399X-619843-004 9643 9726 9884
5.1.2.2 120337-13 06.19.25.10 N399X-619843-004 9643 9726 9884
5.1.3.2 120337-13 06.19.25.10 N399X-619843-004 9643 9726 9884
5.1.3.2 controlled 06.19.25.13d  
5.1.3.2 controlled 06.19.25.14d  
6.0.0.10 n/a 06.19.25.16 N399X-619843-004 9643 9726 9887 9330 9643 9565 9726
6.0.1.11 n/a 06.19.25.16 N399X-619843-004 9643 9726 9887 9330 9643 9565 9726
6.1.0.16   06.60.11.10 N399X-660843-003   9643   9726 98B4 9330 9643   9565   9726
07.10.25.10e N399X-710843-006e 9673   9728   9566   9728  
6.1.0.16 137934-02
137935-02
137936-02
06.60.11.11    
07.10.26.12 N399X-710843-006
6.1.1.10   06.60.11.10 N399X-660843-003   9643   9726 98B4 9330 9643   9565   9726
07.10.25.10e N399X-710843-006e 9673   9728   9566   9728  
6.1.1.10 139034-01
139035-01
139036-01
06.60.11.11    
07.10.26.12 N399X-710843-006
6.1.2.8   06.60.11.10 N399X-660843-003   9643   9726 98B4 9330 9643   9565   9726
07.10.25.10f N399X-710843-006f 9673   9728   9566   9728  
6.1.2.8 139339-01
139340-01
139341-01
06.60.11.11    
07.10.26.12  
6.1.2.8 139339-02
139340-02
139341-02
06.60.11.11    
07.10.26.12  
6.2.0.13   06.60.11.11 N399X-660843-003 9681 9728 98C1 9330 9681 9566 9728
07.15.11.11g N399X-710843-006
6.2.0.14 140060-01
140061-01
140062-01
   
07.15.11.12h  
6.2.0.14 140060-02
140061-02
140062-02
   
07.15.11.12h  
6.3.0   (CAM 6.3 was never released.)
6.4.0.10   06.60.11.11 N399X-660843-003 9681 9728 98C4 9330 9681 9566 9728
07.50.08.10 N399X-750843-002
6.4.1.5   06.60.22.10 N399X-660843-003 9682 9728 98C4 9330 9682 9566 9728
07.50.13.10 N399X-750843-002
6.5.0.10   06.60.22.10 N399X-660843-003 9682 9728 98C4 9330 9682 9566 9728
07.60.18.10 N399X-760843-003
6.5.0.x controlled (06.60.22.10) N399X-660843-039i  
(07.1x.xx.xx)
(07.50.xx.xx)
(07.60.18.10)
N399X-710843-069i
n/a
N399X-760843-039i
6.5.0.x controlled    
(7.60.18.10) N399X-760843-004j
6.5.0.x controlled    
(7.60.18.10) N399X-760843-049k
6.6.0.11l   06.60.22.10 N399X-660843-003 9682 9728 98D0 9330 9682 9566 9728
07.60.18.13 N399X-760843-005
6.6.0.12l 141474-01l
141475-01 
141476-01 
(CR6935284 CAM BUI host types do not match array hostregion.)
6.6.0.12 143759-01
143760-01
143761-01
   
07.60.36.10  
6.7.0.12   06.60.22.10 N399X-660843-003 9682 9728 98D3 9330 9682 9566 9728
07.60.36.13 N399X-760843-005
6.7.0.13 (Windows Only) 144861-01 (CAM core patch for Windows only. Fixes CR6968739 J4410 reporting incorrect chassis serial number; and CR6972298 Win2008 undefined constant.)
6.7.0.x 145965-02
145966-02
145967-02
  (Seagate drives firmware fixes for 6000/2500/J4000; 6000/2500 controller firmware fixes. Includes all previous fixes in 14596[567]-*.)
07.60.53.10  
6.7.0.x 145965-03
145966-03
145967-03
  (For F5100 FMOD firmware fixes FMODs zombie during db restore operation. Includes all previous fixes in 14596[567]-*.)
07.60.53.10  
6.7.0.14 (SPARC Only) 144860-02 (CAM core patch for Solaris SPARC only. Fishwrap 3.7.4-3 bug fixes.)
6.8.0.20   06.60.22.10 N399X-660843-003 9682 9728 98D3 9330 9682 9566 9728
07.60.53.10 N399X-760843-005
6.8.1.4   06.60.22.10 N399X-660843-003 9682 9728 98D4 9330 9682 9566 9728
07.60.56.10 N399X-760843-005 98E4
6.9.0.16   06.60.22.10 N399X-660843-003 9682 9728 98D6 9330 9682 9566 9728
07.60.56.10 N399X-760843-005
6.9.0.18
(platform patch)
147416-01
147417-01
147418-01
147419-01
CAM Platform patch to address CAM CRs 7104329,7151045 and 7147147
Refer Patch Readme notes for more details.
6.9.0.18
(firmware patch)
147660-03
147661-02
147662-02
No f/w update for 6.x Drive firmware E6C0 for drives HUS1530FCSUN300G and HUS1561FCSUN600G
07.60.63.10  
6.9.0.20
(platform patch)
147416-02
147417-02
147418-02
147419-02
CAM Platform patch to address CAM CRs and to support new features
Refer Patch Readme notes for more details.
6.9.0.20
(firmware patch)
147660-04
147661-03
147662-03
Drive firmware 0712 for drive ST31000NSSUN1.0T
6.9.0.20
(firmware patch)
147660-05
147661-04
147662-04
Hitachi and Seagate Drives firmware
Refer Patch Readme notes for more details.

6.9.0.27(Platform patch)

147417-03
147418-03
Latest CAM platform patch for Windows and Linux. Refer to patch readme for more details like bug fixes etc. For Solaris, install CAM version 6.10.2.2.

6.9.0.27m

(Latest firmware patch)

Linux and Windows

147661-06
147662-06
06.60.22.10 N399X-660843-003 9682 9728 98D6 9330 9682 9566 9728
07.60.63.10 N399X-760843-005
6.10.0.5n   06.60.22.10 N399X-660843-003 9682 9728 98D6 9330 9682 9566 9728
07.60.63.10 N399X-760843-005
6.10.2.2n   06.60.22.10 N399X-660843-003 9682 9728 98D6 9330 9682 9566 9728
07.60.63.10 N399X-760843-005
Baseline / CAM Release Patch Firmware NVSRAM CSM100 FC CSM100 SATA CSM200 FLA200 FC FLA300 FC FLC200 dSATA FLC200 iSATA
Controller Expansion
Sun Storage 6140 Array Firmware
NOTE: Firmware shown as "controlled" are not publicly available and is only provided on a case-by-case basis as deemed necessary by support services.

a Temporary fix for Sun Alert 102757 - 6140/6540 Exp Tray Firmware (IOM 9865) May Cause Loss of Access to Mulitple Disks. Permanent fix in baseline 5.1 with IOM 9884.
b Some interim build before 06.19.23.10 may have been released to some customers as temporary fix, these should be updated to 5.1 baseline or later ASAP.
c Sun StorEdge 5000 NAS Gateway bug fix.
d 06.19.25.13/23 and 06.19.25.14/.24 were early access releases of .16/26. Customers with this firmware should be updated to .16/26. Note that .14 contains all fixes in .13 and supersedes it.
e 7.10 firmware is an optional upgrade and is not bundled in CAM 6.1.0 or 6.1.1. (Refer to sun.com/download for Sun StorageTek 6000 Series Array Firmware Upgrade Utility.)
f 7.10.25.10 firmware is now bundled in CAM 6.1.2 but is still an optional upgrade. Separate utility still needed to upgrade from 06.x to 07.10.25.10. (Refer to sun.com/download for Sun StorageTek 6000 Series Array Firmware Upgrade Utility.)
g 7.15.11.11 firmware is bundled with CAM 6.2.0.13. Separate utility still needed to upgrade from 06.x to 07.10, then from 07.10 to 07.15 by CAM. (Refer to sun.com/download for Sun StorageTek 6000 Series Array Firmware Upgrade Utility.)
h Fixes CR6757957 "Auto Code Sync feature failed during controller replacement ... (6140, 6540, FLX380)"
i Temporary fix in NVSRAM for CR6704575 PFA issue.
j Temporary fix in NVSRAM for CR6913694 bad host regions.
k Temporary fix in NVSRAM for CR6913694 bad host regions and CR6704575 PFA issue.
l CAM 6.6.0.11 host types do not match array's host region (CR6935284), affecting 2500, 6140, 6180, 6540, 6580/6780. This may result in either new mappings selecting the wrong host region, or user confused by the display and change existing mappings which was correct, to become wrong. CAM 6.6.0.12 through patch 14147[456]-01 was specifically released to resolve this bug.

m New firmware patch for Windows and Linux which includes latest array firmware and Hitachi drives firmware. For Solaris, install latest CAM 6.10.2.2.
n Sun Storage Common Array Manager version 6.10 is available for Solaris only.

 

Do you still have questions?  You can use My Oracle Support Communities.  Communities put you in touch with industry professionals like yourself.  They are monitored by Oracle support engineers, so you can expect reliable and correct answers.  Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback