Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1011402.1
Update Date:2017-11-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1011402.1 :   Sun Ultra[TM] 45, Sun Fire[TM] V215/V245/V445 io.fabric errors  


Related Items
  • Sun Fire V215 Server
  •  
  • Sun Ultra 45 Workstation
  •  
  • Sun Fire V245 Server
  •  
  • Sun Fire V445 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
  •  
  • _Old GCS Categories>Sun Microsystems>Desktops>Workstations
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
215637


Applies to:

Sun Ultra 45 Workstation - Version Not Applicable and later
Sun Fire V215 Server - Version Not Applicable and later
Sun Fire V245 Server - Version Not Applicable and later
Sun Fire V445 Server - Version Not Applicable and later
All Platforms

Goal

 The Sun Ultra[TM] 45, Sun Fire V215/V245 and Sun Fire V445 may experience massive io.fabric errors

Solution

Steps to Follow

The Sun Ultra 45, Sun Fire V215/V245 and Sun Fire V445 may experience massive io.fabric errors due to correctable errors being generated from the graphics card XVR-300 or XVR-2500, installed in PCIE slot. These messages do not indicate a need to replace the system board.

Example:

fmdump-e.out
TIME                 CLASS
Aug 16 03:28:20.4025 ereport.io.fire.fabric
Aug 16 03:36:01.6126 ereport.io.fire.fabric
Aug 16 03:39:36.2185 ereport.io.fire.fabric
........
........
........
Aug 16 04:01:36.8122 ereport.io.fire.fabric
Aug 16 04:06:05.2800 ereport.io.fire.fabric
Aug 16 04:06:55.0423 ereport.io.fire.fabric

To correct this issue append the following lines to the /etc/system file

set pcie:pcie_aer_ce_mask=0x11C1
set pcie_expected_ce_mask=0x11C1

Reboot the system to implement these changes.

After adding these lines to the /etc/system file you may see the following message appear during Solaris boot:

Sorry, variable  pcie_expected_ce_mask is not defined in the kernel.

If this message is seen, delete the line "set pcie_expected_ce_mask=0x11C1".
Then reboot the system.



Product
Sun Ultra 45 Workstation
Sun Fire V215/V245 Server
Sun Fire V445 Server

References

<BUG:6393859> - ATG1203D3FUNC:REPUBLISH BUTTON IN SEARCH PAGE VISIBLE AND ENABLED ONLY IN US.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.