Solution Type  Technical Instruction Sure

Solution  1011397.1 :   Sun Fire[TM] V250 Advanced Lights Out Management showfru output shows failing crc test on SCSIBP fruprom  


Related Items
  • Sun Fire V250 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
215632


Applies to:

Sun Fire V250 Server - Version All Versions and later
All Platforms

Goal

 Earlier versions of Advanced Lights Out Management (ALOM) do not output the seeprom information for SCSIBP.SEEPROM when using the showfru ALOM command.
Using ALOM 1.2 and ALOM 1.3, the SCSI.SEEPROM does not show the 'crc test fail' message. Using ALOM versions 1.4 through 1.5.5, it starts to fail the crc test on the content of the fruprom.

Fix

Steps to Follow
ALOM version 1.5.5 and lower do not print FRU_PROM at SCSIBP.SEEPROM information. Instead the showfru output may show the following:

FRU_PROM at SCSIBP.SEEPROM
ERROR: crc test failed
Failed to print information.


To address this issue upgrade to the latest available ALOM version. ALOM versions 1.6.1 and higher output the correct information.