Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1011046.1
Update Date:2013-03-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1011046.1 :   Sun Ultra[TM] 45: Pre-install Disk Partition Information  


Related Items
  • Sun Ultra 45 Workstation
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: USx
  •  
  • _Old GCS Categories>Sun Microsystems>Desktops>Workstations
  •  

PreviouslyPublishedAs
215209


Applies to:

Sun Ultra 45 Workstation - Version Not Applicable and later
All Platforms

Goal

 On Sun Ultra[TM] 45 workstations, the system comes pre-installed with Solaris[TM] 10 Operating System (1/06).

Fix

Steps to Follow

HDI partitions for 250 GB
-------------------------
Disk Partition Layout BEFORE installing Solaris Operating System on a new Sun Ultra 45 workstation:
Current partition table (original):
Total disk cylinders available: 65533 + 2 (reserved cylinders)
Part      Tag    Flag     Cylinders         Size            Blocks
0 unassigned    wm     564 -  6201       20.00GB    (5638/0/0)   41946720
1 unassigned    wm       6 -   563        1.98GB    (558/0/0)     4151520
2     backup    wm       0 - 65532      232.49GB    (65533/0/0) 487565520
3       root    wm    6202 -  7611        5.00GB    (1410/0/0)   10490400
4       swap    wu    7612 -  8175        2.00GB    (564/0/0)     4196160
5 unassigned    wm    8176 - 25088       60.00GB    (16913/0/0) 125832720
6 unassigned    wm   25089 - 65532      143.48GB    (40444/0/0) 300903360
7 unassigned    wm       0 -     5       21.80MB    (6/0/0)         44640
Disk Partition Layout AFTER Solaris Operating System has been installed:
Part      Tag    Flag     Cylinders         Size            Blocks
0 unassigned    wm     564 -  6201       20.00GB    (5638/0/0)   41946720
1       swap    wu       0 -   563        2.00GB    (564/0/0)     4196160
2     backup    wm       0 - 65532      232.49GB    (65533/0/0) 487565520
3 unassigned    wm    6202 - 65526      210.47GB    (59325/0/0) 441378000
4 unassigned    wu       0                0         (0/0/0)             0
5 unassigned    wu       0                0         (0/0/0)             0
6 unassigned    wu       0                0         (0/0/0)             0
7 unassigned    wm   65527 - 65532       21.80MB    (6/0/0)         44640
/etc/vfstab:
#device           device          mount            FS     fsck   mount   mount
#to mount         to fsck         point            type   pass   at boot options
/devices          -               /devices         devfs   -      no      -
/proc             -               /proc            proc    -      no      -
ctfs              -               /system/contract ctfs    -      no      -
objfs             -               /system/object   objfs   -      no      -
fd                -               /dev/fd          fd      -      no      -
swap              -               /tmp             tmpfs   -      yes     -
/dev/dsk/c1t0d0s0 /dev/rdsk/c1t0d0s0 /             ufs     1      no      -
/dev/dsk/c1t0d0s3 /dev/rdsk/c1t0d0s3 /space        ufs     1      yes     -
/dev/dsk/c1t0d0s1 -               -                swap    -      no      -
The exact configuration that has been preinstalled on the primary hard drive is:
Slice                 Name              Size
0                     / (root)          11GB
1                     swap              2 GB
2                     backup            entire Disk
3                     unassigned
4                     unassigned
5                     var               6GB
6                     unassigned
7                     /space            230GB



Product
Sun Ultra 45 Workstation


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.