![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1009415.1 : How to determine the installed version of Volume System Products Hardware Platform ALOM (Advanced Lights Out Management) firmware
PreviouslyPublishedAs 213014 Applies to:Sun Fire V240 Server - Version Not Applicable and laterSun Fire V250 Server - Version Not Applicable and later Sun Netra 210 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Fire V440 Server - Version Not Applicable and later Sun Fire V445 Server - Version Not Applicable to Not Applicable [Release N/A] All Platforms GoalDescription FixSteps to Follow To obtain the current ALOM version installed on your system execute either of the the following commands: From Solaris: # /usr/platform/`uname -i`/sbin/scadm version -v
From within ALOM: sc> showsc
The latest/current version of ALOM is always available from MyOracleSupport website under patches and downloads You can reach that web site, starting from the following link: you can also review How to Download Firmware for Oracle Systems and Storage (Doc ID 1342226.1)
ALOM 1.6.10 Firmware for Sun Fire V215, V245 and V445
ALOM_1.6.10_fw_hw8.tar.gz 20.36 MB ALOM 1.6.10 Firmware for Sun Fire V125, V210, V240, V250, V440, and Netra 210, 240 and 440 ALOM_1.6.10_fw_hw0.tar.gz 20.11 MB
Additional Information:
From Solaris: # /usr/platform/`uname -i`/sbin/scadm version -v
SC Version v1.6 SC Bootmon Version: v1.6.3 SC Bootmon checksum: B420A0FC SC Firmware Version: v1.6.3 SC Build Release: 01 SC firmware checksum: 9C0A2AFC SC firmware built: Dec 22 2006, 15:15:30 SC System Memory Size: 8MB SC NVRAM Version = f SC hardware type: 1 From ALOM:
sc> showsc Advanced Lights Out Manager v1.6.3 parameter value --------- ----- if_network true if_modem false if_connection telnet if_emailalerts false sys_autorestart xir sys_bootrestart none sys_bootfailrecovery none sys_maxbootfail 3 sys_xirtimeout 900 sys_boottimeout 120 sys_wdttimeout 60 netsc_tpelinktest true netsc_dhcp false netsc_ipaddr xx.xx.xx.xx netsc_ipnetmask xxx.xxx.xxx.xxx netsc_ipgateway xx.xx.xx.xx mgt_mailhost mgt_mailalert sc_customerinfo sc_escapechars #. sc_powerondelay false sc_powerstatememory false sc_clipasswdecho true sc_cliprompt sc sc_clitimeout 0 sc_clieventlevel 2 sc_backupuserdata true sys_eventlevel 2 ser_baudrate 9600 ser_parity none ser_stopbits 1 ser_data 8 netsc_enetaddr 00:xx:00:00:00:xx sys_hostname v440 sys_enetaddr 00:xx:00:00:00:xx
ReferencesAttachments This solution has no attachment |
||||||||||||
|