Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1007945.1
Update Date:2017-10-18
Keywords:

Solution Type  Technical Instruction Sure

Solution  1007945.1 :   Sun Fire[TM] 3800/48x0/6800/E4900/E6900/E2900/v1280 Servers: Capacity on Demand (COD) 2.0 Installation FAQ  


Related Items
  • Sun Netra 1280 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Netra 1290 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
210957


Applies to:

Sun Fire 6800 Server - Version All Versions and later
Sun Fire E2900 Server - Version All Versions and later
Sun Fire E4900 Server - Version All Versions and later
Sun Fire E6900 Server - Version All Versions and later
Sun Netra 1280 Server - Version All Versions and later
All Platforms

Goal

 This document is an overview of Capacity on Demand (COD) program, and contains frequently asked questions on COD.

Solution

Steps to Follow
Sun Fire[TM] 3800/48x0/6800/E4900/E6900/E2900/v1280 Servers: Capacity on Demand (COD) 2.0 Installation FAQ

1) COD Overwiew

The COD option provides an economical means to add additional CPU resources which can be turned on and off depending on system load. The COD option utilizes special COD CPU/Memory boards that are installed in your system. They become active at your command and you will be billed only for the time they are active. Sun Fire[TM] 3800/48x0/6800/E4900/E6900/E2900/v1280 servers come configured with a minimum number of standard (active) CPU/Memory boards. COD Boards only add extra capacity to already configured domains.

Your system can have a mix of both standard and COD CPU/Memory boards installed, up to the maximum capacity allowed for the system. All Domains must have at a minimum, at least one active CPU with 1 bank of memory installed local to the CPU.

If you would like the flexibility of the COD option, and your system is not currently configured with COD CPU/Memory boards, contact your Sun sales representative or authorized Sun reseller to purchase COD CPU/Memory boards. Your salesperson and service provider will team to install the COD CPU/Memory boards in your system.

2) COD Licensing Process

COD RTU licenses are required to enable COD CPU resources. COD licensing involves the following tasks:

A. Obtaining COD RTU License Certificates and COD RTU license keys for COD resources to be enabled

You can purchase COD RTU licenses at any time from your Sun sales representative or reseller. You can then obtain a license key (for the COD resources purchased) from the Sun License Center.

B. Entering the COD RTU license keys in the COD license database

The COD license database stores the license keys for the COD resources that you enable. You record this license information in the COD license database by using the addcodlicense command. The COD RTU licenses are considered as floating licenses and can be used for any COD CPU resource installed in the system.

Link to License Website: Oracle licensing center

3) Instant Access CPU (Headroom)

If you require COD CPU resources before you complete the COD RTU license purchasing process, you can temporarily enable a limited number of resources called instant access CPUs (also referred to as headroom). These instant access CPUs are available as long as there are unlicensed COD CPUs in the system. The maximum number of instant access resources available on Sun Fire midframe systems is four CPUs. Instant access CPUs are disabled by default on Sun Fire midframe systems. If you want to use these resources, you activate them by using the setupplatform command.

4) Getting started with COD

Before you can use COD on Sun Fire 6800/4810/4800/3800 servers, you must complete certain prerequisites. These tasks include the following:

A. Installing the same version of the Sun Fire 6800/4810/4800/3800 firmware (5.14.0) on both the main and spare system controller (SC).

For details on upgrading the firmware, refer to the "Install.info" file that accompanies the firmware release.

Note: Sun Fire 6800/4810/4800/3800 servers firmware before version 5.14.0 will not recognize COD CPU/Memory boards.

B. Contacting your Sun sales representative or reseller and doing the following:

  • Signing the COD contract addendum, in addition to the standard purchasing agreement contract for your Sun Fire 6800/4810/4800/3800 server.
  • Purchasing COD CPU/Memory boards and arranging for their installation.
  • Performing the COD RTU licensing process as described in To Obtain and Add a COD RTU License Key to the COD License Database. Link to License Website: Oracle licensing center

5) Managing COD RTU Licenses

COD RTU license management involves the acquisition and addition of COD RTU licenses keys to the COD license database. You can also remove COD RTU licenses from the license database if needed.

Be aware that COD license key information is always associated with a particular system. You may encounter invalid COD RTU licenses if you do any of the following:

  • Move a System Controller board from one system to another.
  • Copy the platform and domain configuration files (from the dumpconfig command) from one system to another, and restore the configuration files on the second system by running the "restoreconfig" command.

Any COD RTU license keys for the original system now reside on the second system, but the license keys remain associated with the original system. These license keys will be considered invalid. To prevent invalid COD RTU license keys, run the "setdefaults" command on the first system (to set the default system configuration values), before you remove a System Controller board or before you use the "dumpconfig" command to save the platform and domain configurations. If you do not run the the "setdefaults" command on the first system, you can run the command on the second system before you insert the System Controller board.

6) Packages and location

COD was first included in Firmware 5.14.0 

Scapp: 5.14.0
RTOS version: 26

7) How to check the status before installing COD license?

    v4u-4810a-p1-sc0:SC> showcodlicense
    Description  Ver   Expiration  Count  Status
    -----------  ---   ----------  -----  ------
    v4u-4810a-p1-sc0:SC> showcodusage
    Resource      In Use  Installed  Licensed  Status
    --------      ------  ---------  --------  ------
    PROC               0          0         0  OK: 0 PROCs available Headroom: 4
    Domain/Resource  In Use  Installed  Reserved
    ---------------  ------  ---------  --------
    A - PROC              0          0         4
    B - PROC              0          0         0
    C - PROC              0          0         0
    D - PROC              0          0         0
    Unused - PROC         0          0         0
    v4u-4810a-p1-sc0:SC> showsc
    SC: SSC0  
    Main System Controller
    SC Failover: enabled but not active.
    Clock failover enabled.
    SC date: Mon Oct 07 16:55:47 PDT 2002
    SC uptime: 3 days 1 hour 7 minutes 46 seconds 
    ScApp version: 5.14.0 Patch-ID_112883-01
    RTOS version: 26
    v4u-4810a-p1-sc0:SC> showb
    Slot     Pwr Component Type                 State      Status     Domain
    ----     --- --------------                 -----      ------     ------
    SSC0     On  System Controller              Main       Passed     -        
    SSC1     On  System Controller              Spare      -          -        
    ID0      On  Sun Fire 4810 Centerplane      -          OK         -        
    PS0      On  A152 Power Supply              -          OK         -        
    PS1      On  A152 Power Supply              -          OK         -        
    PS2      On  A152 Power Supply              -          OK         -        
    FT0      On  Fan Tray                       Low Speed  OK         -        
    FT1      On  Fan Tray                       Low Speed  OK         -        
    FT2      On  Fan Tray                       Low Speed  OK         -        
    RP0      On  Repeater Board                 -          OK         -        
    RP2      On  Repeater Board                 -          OK         -        
    /N0/SB0  On  CPU Board V2                   Active     Degraded   A
    SB2      Off CPU Board V2                   Available  Not tested Isolated
    /N0/IB6  On  PCI I/O


Product
Sun Netra 1290 Server
Netra 1280 Server
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire E2900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server


Keywords: COD, normalized
Previously Published As 81531



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback