![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1007945.1 : Sun Fire[TM] 3800/48x0/6800/E4900/E6900/E2900/v1280 Servers: Capacity on Demand (COD) 2.0 Installation FAQ
PreviouslyPublishedAs 210957 Applies to:Sun Fire 6800 Server - Version All Versions and laterSun Fire E2900 Server - Version All Versions and later Sun Fire E4900 Server - Version All Versions and later Sun Fire E6900 Server - Version All Versions and later Sun Netra 1280 Server - Version All Versions and later All Platforms GoalThis document is an overview of Capacity on Demand (COD) program, and contains frequently asked questions on COD. SolutionSteps to Follow 1) COD Overwiew The COD option provides an economical means to add additional CPU resources which can be turned on and off depending on system load. The COD option utilizes special COD CPU/Memory boards that are installed in your system. They become active at your command and you will be billed only for the time they are active. Sun Fire[TM] 3800/48x0/6800/E4900/E6900/E2900/v1280 servers come configured with a minimum number of standard (active) CPU/Memory boards. COD Boards only add extra capacity to already configured domains. Your system can have a mix of both standard and COD CPU/Memory boards installed, up to the maximum capacity allowed for the system. All Domains must have at a minimum, at least one active CPU with 1 bank of memory installed local to the CPU. If you would like the flexibility of the COD option, and your system is not currently configured with COD CPU/Memory boards, contact your Sun sales representative or authorized Sun reseller to purchase COD CPU/Memory boards. Your salesperson and service provider will team to install the COD CPU/Memory boards in your system. 2) COD Licensing Process COD RTU licenses are required to enable COD CPU resources. COD licensing involves the following tasks: A. Obtaining COD RTU License Certificates and COD RTU license keys for COD resources to be enabled You can purchase COD RTU licenses at any time from your Sun sales representative or reseller. You can then obtain a license key (for the COD resources purchased) from the Sun License Center. B. Entering the COD RTU license keys in the COD license database The COD license database stores the license keys for the COD resources that you enable. You record this license information in the COD license database by using the addcodlicense command. The COD RTU licenses are considered as floating licenses and can be used for any COD CPU resource installed in the system. Link to License Website: Oracle licensing center 3) Instant Access CPU (Headroom) If you require COD CPU resources before you complete the COD RTU license purchasing process, you can temporarily enable a limited number of resources called instant access CPUs (also referred to as headroom). These instant access CPUs are available as long as there are unlicensed COD CPUs in the system. The maximum number of instant access resources available on Sun Fire midframe systems is four CPUs. Instant access CPUs are disabled by default on Sun Fire midframe systems. If you want to use these resources, you activate them by using the setupplatform command. 4) Getting started with COD Before you can use COD on Sun Fire 6800/4810/4800/3800 servers, you must complete certain prerequisites. These tasks include the following: A. Installing the same version of the Sun Fire 6800/4810/4800/3800 firmware (5.14.0) on both the main and spare system controller (SC). For details on upgrading the firmware, refer to the "Install.info" file that accompanies the firmware release. Note: Sun Fire 6800/4810/4800/3800 servers firmware before version 5.14.0 will not recognize COD CPU/Memory boards. B. Contacting your Sun sales representative or reseller and doing the following:
5) Managing COD RTU Licenses COD RTU license management involves the acquisition and addition of COD RTU licenses keys to the COD license database. You can also remove COD RTU licenses from the license database if needed. Be aware that COD license key information is always associated with a particular system. You may encounter invalid COD RTU licenses if you do any of the following:
Any COD RTU license keys for the original system now reside on the second system, but the license keys remain associated with the original system. These license keys will be considered invalid. To prevent invalid COD RTU license keys, run the "setdefaults" command on the first system (to set the default system configuration values), before you remove a System Controller board or before you use the "dumpconfig" command to save the platform and domain configurations. If you do not run the the "setdefaults" command on the first system, you can run the command on the second system before you insert the System Controller board. 6) Packages and location COD was first included in Firmware 5.14.0 Scapp: 5.14.0 7) How to check the status before installing COD license? v4u-4810a-p1-sc0:SC> showcodlicense Description Ver Expiration Count Status ----------- --- ---------- ----- ------ v4u-4810a-p1-sc0:SC> showcodusage Resource In Use Installed Licensed Status -------- ------ --------- -------- ------ PROC 0 0 0 OK: 0 PROCs available Headroom: 4 Domain/Resource In Use Installed Reserved --------------- ------ --------- -------- A - PROC 0 0 4 B - PROC 0 0 0 C - PROC 0 0 0 D - PROC 0 0 0 Unused - PROC 0 0 0 v4u-4810a-p1-sc0:SC> showsc SC: SSC0 Main System Controller SC Failover: enabled but not active. Clock failover enabled. SC date: Mon Oct 07 16:55:47 PDT 2002 SC uptime: 3 days 1 hour 7 minutes 46 seconds ScApp version: 5.14.0 Patch-ID_112883-01 RTOS version: 26 v4u-4810a-p1-sc0:SC> showb Slot Pwr Component Type State Status Domain ---- --- -------------- ----- ------ ------ SSC0 On System Controller Main Passed - SSC1 On System Controller Spare - - ID0 On Sun Fire 4810 Centerplane - OK - PS0 On A152 Power Supply - OK - PS1 On A152 Power Supply - OK - PS2 On A152 Power Supply - OK - FT0 On Fan Tray Low Speed OK - FT1 On Fan Tray Low Speed OK - FT2 On Fan Tray Low Speed OK - RP0 On Repeater Board - OK - RP2 On Repeater Board - OK - /N0/SB0 On CPU Board V2 Active Degraded A SB2 Off CPU Board V2 Available Not tested Isolated /N0/IB6 On PCI I/O Product Sun Netra 1290 Server Netra 1280 Server Sun Fire E6900 Server Sun Fire E4900 Server Sun Fire E2900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Keywords: COD, normalized Previously Published As 81531 Attachments This solution has no attachment |
||||||||||||
|