All Platforms

Goal

 The device nodes are probed during the boot sequence. On the SB2500 the PCI slots are probed in the following order.

Fix

Steps to Follow

Probe Order Slot Identifier Slot Position Device Node

  1           PCI 5                Top            /devices/pci@1f,700000 device 3
2           PCI 4             2nd from top      /devices/pci@1e,600000 device 2
3           PCI 1             2nd from bott.    /devices/pci@1e,600000 device 3
4           PCI 0               Bottom          /devices/pci@1e,600000 device 4
5           PCI 2             3rd from bottom   /devices/pci@1d,700000 device 5
6           PCI 3             4th from bottom   /devices/pci@1c,600000 device 1  