Asset ID: |
1-71-1007692.1 |
Update Date: | 2017-12-11 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1007692.1
:
Sun Storage 3510 and 3511 Arrays: How to Identify Switch IDs, Disk IDs and Correct Backend Cabling
Related Items |
- Sun Storage 3511 SATA Array
- Sun Storage 3510 FC Array
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Arrays>SN-DK: SE31xx_33xx_35xx
|
PreviouslyPublishedAs
210659
Applies to:
Sun Storage 3510 FC Array - Version Not Applicable and later
Sun Storage 3511 SATA Array - Version Not Applicable and later
All Platforms
Goal
This document describes how to identify the disk IDs when the ID Selection Switch of the Sun Storage 3510 and 3511 Arrays are set to numbers 0-7. It also explains how to identify the cabling schemes for these devices.
Solution
For more information about the loop IDs of disks in the expansion units of the 3510 and 3511, refer to Section 4.6 of the Sun StorEdge 3000 Family Installation, Operation, and Service Manual. The tables below provides the details about Loop ID of each disk in 8 expansion units, which is the maximum supported configuration.
Chassis ID Switch | Disk ID Range |
0 |
0-15 |
1 |
16-31 |
2 |
32-47 |
3 |
48-63 |
4 |
64-79 |
5 |
80-95 |
6 |
96-111 |
7 |
112-125 |
Target Disk drive(s) Loop IDs are 0-11(ID Switch is set to 0; Chassis ID 0)
0 3 6 9
1 4 7 10
2 5 8 11 (SES Loop ID is 12)
Target Disk drive(s) Loop IDs are 16-27 (ID Switch is set to 1; Chassis ID 1)
16 19 22 25
17 20 23 26
18 21 24 27 (SES Loop ID is 28)
Target Disk drive(s) Loop IDs are 32-43 (ID Switch is set to 2;Chassis ID 2)
32 35 38 41
33 36 39 42
34 37 40 43 (SES Loop ID is 44)
Target Disk drive(s) Loop IDs are 48-59 (ID Switch is set to 3;Chassis ID 3)
48 51 54 57
49 52 55 58
50 53 56 59 (SES Loop ID is 60)
Target Disk drive(s) Loop IDs are 64-75 (ID Switch is set to 4;Chassis ID 4)
64 67 70 73
65 68 71 74
66 69 72 75 (SES Loop ID is 76)
Target Disk drive(s) Loop IDs are 80-91 (ID Switch is set to 5;Chassis ID 5)
80 83 86 89
81 84 87 90
82 85 88 91 (SES Loop ID is 92)
Target Disk drive(s) Loop IDs are 96-107 (ID Switch is set to 6;Chassis ID 6)
96 99 102 105
97 100 103 106
98 101 104 107 (SES Loop ID is 108)
Target Disk drive(s) Loop IDs are 112-123 (ID Switch is set to 7;Chassis ID 7)
112 115 118 121
113 116 119 122
114 117 120 123 (SES Loop ID is 124)
The recommended cabling configuration and the steps to connect expansion units are given in Section 4.5 of the Sun StorEdge 3000 Family Installation, Operation, and Service Manual. The cabling diagrams to connect the maximum of 8 expansion units are given on pages 43-56 of the Sun StorEdge 3000 Family Best Practices Manual.
Attachments
This solution has no attachment