![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1007567.1 : Sun Fire[TM] 12K/15K/E20K/E25K: How to Update the Flash Proms (FPROMs) on a System Board
PreviouslyPublishedAs 210472 Applies to:Sun Fire 12K Server - Version All Versions to All Versions [Release All Releases]Sun Fire 15K Server - Version All Versions to All Versions [Release All Releases] Sun Fire E20K Server - Version All Versions to All Versions [Release All Releases] Sun Fire E25K Server - Version All Versions to All Versions [Release All Releases] All Platforms GoalDescription SolutionSteps to Follow
Updating the FPROMs on all the system boards in a domain (example below uses domain 'a') On the MAIN sc (as sms-svc) run: mc15k-sc1:sms-svc:4> flashupdate -d a -f /opt/SUNWSMS/SMS1.4.1/hostobjs/sgcpu.flash Current System Board FPROM Information ======================================== CPU at SB0, FPROM 0: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB0, FPROM 1: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB1, FPROM 0: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB1, FPROM 1: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB2, FPROM 0: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB2, FPROM 1: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB16, FPROM 0: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB16, FPROM 1: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 Flash Image Information ========================== POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 Do you wish to update the FPROM (yes/no) y NOTE: You can update the flash PROMs on the system boards while the Solaris[TM] Operating Environment is active in the domains. The flash PROM revision will not be in effect until the system boards are powered off/on using setkeyswitch or DR operations. If you would like to update only ONE system board on the platform, then you specify the board location as follows: mc15k-sc1:sms-svc:6> flashupdate -f /opt/SUNWSMS/SMS1.4.1/hostobjs/sgcpu.flash sb0 Current System Board FPROM Information ======================================== CPU at SB0, FPROM 0: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 CPU at SB0, FPROM 1: POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 Flash Image Information ========================== POST 05/10/04 14:56:00 Release 5.17.1 Build 4.0 I/F 12 OBP 05/10/04 14:55:00 Release 5.17.1 Build 4.0 Ver 05/10/04 14:59:00 Release 5.17.1 Build 4.0 Do you wish to update the FPROM (yes/no) y NOTE: Answering no to either question above will not flash the firmware on the System Board(s). It is the method you use to simply view the firmware revision of the System Board. Please refer to the flashupdate MAN page for command options and details. Product Sun Fire 15K Server Sun Fire 12K Server Sun Fire E25K Server Sun Fire E20K Server flashupdate, SMS, FPROM Previously Published As 47468 Attachments This solution has no attachment |
||||||||||||
|