![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1007177.1 : SL8500 - dWWN Requirement on the SL8500 Library
PreviouslyPublishedAs 209886 Oracle Confidential PARTNER - Available to partners (SUN). Reason: Confidential for Partners and Oracle Support personnel Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms GoalSun StorageTek[TM] SL8500 Modular Library System, DWWN Requirement on the SL8500. SolutionSteps to Follow Fibre drives installed in the SL8500 will be assigned a WWN based on the drive bay position. All Fibre drives housed in the SL8500 require DWWN support; there is no option to disable this feature. As a result drives migrated from other libraries will get assigned a different WWN upon installation in the SL8500. If the customer binds to the WWN this could impact customer operations if this not taken into consideration. Example: STK 9840B Fibre drives converted from a 9310 or L700 library to an SL8500 has this exposure. After the drive is installed in the SL8500 the DWWN will be changed to the appropriate value assigned to its bay position. The SAN environment may not associate this new WWN to the original drive. To resolve this issue the switch may need to be reconfigured or a server may need to be rebooted. The resolution is configuration dependant and needs to be addressed during the conversion. During manufacturing we burn-in a single DWWN per SL8500 Library and based upon that original WWN 225 (decimal) additional WWN are assigned to that library by the embedded code of the SL8500. With an example seed value of 500104F00078CB0E the library code reserves the first 16 (10Hex) values for the Library Fibre interfaces, a possible 8 ports with a possible 8 nodes depending on the configuration. Then drive tray assignments are allocated starting at drive bay 1. The HBT card (drive interface) is then given the drive WWN base value of 500104F00078CB1E. Then drive WWN?s are assigned by the drive Bay Number, starting with drive bay 1 and ending with drive bay 64. Example: Drive Bay 1 Node Name 500104F00078CB1E Drive Bay 1 Port A Name 500104F00078CB1F Drive Bay 1 Port B Name 500104F00078CB20 Drive Bay 2 Node Name 500104F00078CB21 Drive Bay 2 Port A Name 500104F00078CB22 Drive Bay 2 Port B Name 500104F00078CB23 ----------------_ETC_------------------- Drive Bay 64 Node Name 500104F00078CBDB Drive Bay 64 Port A Name 500104F00078CBDC Drive Bay 64 Port B Name 500104F00078CBDD Minimum microcode required for STK Fibre drives: Drive Code EC 9840A 1.34.158 129600 9840B 1.34.358 129601 9840C 1.34.558 129602 ESCON/FIBRE Only 9940B 1.34.408 129604 Attachments This solution has no attachment |
||||||||||||
|