![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1006468.1 : How to find the firmware revision (fcode version) of on-board ISP2200 chip
PreviouslyPublishedAs 209063 Applies to:Sun Fire V490 Server - Version All Versions and laterSun Fire V880z Visualization Server - Version All Versions and later Sun Fire V880 Server - Version All Versions and later Sun Fire V890 Server - Version All Versions and later Sun Fire V480 Server - Version All Versions and later All Platforms GoalEver need to find out the fcode version of the on-board ISP2200 chip? SolutionSteps to Follow # luxadm qlgc_s_download Found Path to 1 FC100/P, ISP2200 Devices Opening Device: /devices/pci@8,600000/SUNW,qlc@2/fp@0,0:devctl Detected FCode Version: ISP2200 FC-AL Host Adapter Driver: 1.14 01/11/20 Complete