Solution  1006136.1 :   Sun Fire[TM] V1280/E2900/3800/4800/4810/6800/E4900/E6900 & Netra 1280/1290: How to add CPUs and System Boards to a running domain  


Related Items
  • Sun Netra 1280 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire E6900 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-x8x0/Ex900
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
208592


Applies to:

Sun Fire 3800 Server - Version All Versions and later
Sun Netra 1290 Server - Version All Versions and later
Sun Fire 6800 Server - Version All Versions and later
Sun Netra 1280 Server - Version All Versions and later
Sun Fire E2900 Server - Version All Versions and later
All Platforms

Goal

Utilizing Dynamic Reconfiguration (DR) or cfgadm to add a System Board to a domain.

The procedure outlined in this document can be used to enable a System Board which is not part of any running domain. With some modifications this can be also used to replace a faulty System Board with a new one.

For 3800/48x0/6800/E4900/E6900, please refer to the Dynamic Reconfiguration on Sun Fire Midrange Systems Release Notes to confirm the server meets the requirements.

For V1280/E2900 or Netra 1280/1290, please refer to CPU/Memory Board Replacement and Dynamic Reconfiguration (DR) to confirm the server meets the requirements.

Also reference Sun Fire[TM] Midframe/Midrange Servers: CPU/Memory Board Dynamic Reconfiguration (DR) Considerations (Doc ID 1003332.1) for all available DR options for the Sun Fire[TM] platforms.

Solution

The example procedure below is on a 6800 server and the board being added is SB1.

The following steps are basically the same regardless of the system (but for v1280/E2900/n1280/n1290, there is only one domain and the prompt is not the "SC" prompt, but instead, the "lom" prompt).

1) Make a note of the number of CPUs on the server for comparison purposes once the CPUs have been added

# /usr/sbin/psrinfo
0       on-line   since 02/11/04 15:54:11
1       on-line   since 02/11/04 15:54:12
2       on-line   since 02/11/04 15:54:12
3       on-line   since 02/11/04 15:54:12
#

2) Make a note of the current memory on the server, again, for comparison purposes

# cd /usr/platform/`uname -i`/sbin
# ./prtdiag -v
System Configuration:  Sun Microsystems  sun4u Sun Fire 6800
System clock frequency: 150 MHz
Memory size: 16384 Megabytes
========================= CPUs ===============================================
            Port  Run    E$   CPU      CPU
FRU Name     ID   MHz    MB   Impl.    Mask
----------  ----  ----  ----  -------  ----
/N0/SB0/P0    0   1050   8.0  US-III+  2.3
/N0/SB0/P1    1   1050   8.0  US-III+  2.3
/N0/SB0/P2    2   1050   8.0  US-III+  2.3
/N0/SB0/P3    3   1050   8.0  US-III+  2.3   
========================= Memory Configuration ===============================
                     Logical  Logical  Logical
               Port  Bank     Bank     Bank         DIMM    Interleave Interleave
FRU Name        ID   Num      Size     Status       Size    Factor     Segment
-------------  ----  ----     ------   -----------  ------  ---------- ----------
/N0/SB0/P0/B0    0    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P0/B1    0    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P0/B0    0    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P0/B1    0    3      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B0    1    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B1    1    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B0    1    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B1    1    3      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B0    2    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B1    2    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B0    2    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B1    2    3      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B0    3    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B1    3    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B0    3    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B1    3    3      1024MB    pass          512MB    16-way       0
========================= IO Cards =========================
                                Bus  Max                                  
            IO   Port Bus       Freq Bus  Dev,                            
FRU Name    Type  ID  Side Slot MHz  Freq Func State Name                              Model
----------  ---- ---- ---- ---- ---- ---- ---- ----- --------------------------------  ----------------------
/N0/IB6/P0  PCI   24   B    0    33   33  1,0  ok    pci-pci1011,24.3/pci108e,1000     pci-bridge  
/N0/IB6/P0  PCI   24   B    0    33   33  0,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB6/P0  PCI   24   B    0    33   33  0,1  ok    SUNW,hme-pci108e,1001             SUNW,cheerio
/N0/IB6/P0  PCI   24   B    0    33   33  4,0  ok    SUNW,isptwo-pci1077,1020/sd (blo+ QLGC,ISP1040B
/N0/IB6/P0  PCI   24   B    1    33   33  2,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB6/P0  PCI   24   B    1    33   33  2,1  ok    SUNW,hme-pci108e,1001             SUNW,qsi-cheerio
/N0/IB6/P1  PCI   25   B    5    33   33  2,0  ok    JNI,FCR/sd (block)                FCE-6460-N    
/N0/IB7/P0  PCI   26   B    1    33   33  2,0  ok    pci-pci1011,25.4/pci108e,1000     pci-bridge  
/N0/IB7/P0  PCI   26   B    1    33   33  0,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  0,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    1    33   33  1,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  1,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    1    33   33  2,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  2,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    1    33   33  3,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  3,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    2    33   33  3,0  ok    SUNW,qlc-pci1077,2200.1077.4082.+            
========================= Active Boards for Domain ===========================
          Power  Fault  HotPlug  Board
FRU Name   LED    LED     LED    Cond.
--------  -----  -----  -------  -------
/N0/SB0   on     off    off      ok
/N0/IB6   on     off    off      ok
/N0/IB7   on     off    off      ok       
========================= Available Boards/Slots for Domain ==================
          Power  Fault  HotPlug  Board/Slot  Board/Slot
FRU Name   LED    LED     LED    Condition   Assigned
--------  -----  -----  -------  ----------  ----------
/SB1      off    off    on       Unknown     no
/SB2      on     off    off      Unknown     no
/SB4      off    off    off      Empty       yes
/SB5      off    off    off      Empty       yes
/IB8      on     off    off      Unknown     no  
========================= Hardware Failures ==================================
No Hardware failures found in System
========================= HW Revisions =======================================
System PROM revisions:
----------------------
OBP 5.15.1 05/29/03 17:05
IO ASIC revisions:
------------------
Port
FRU Name    Model            ID  Status Version
----------- --------------- ---- ------ -------
/N0/IB6/P0  SUNW,schizo      24   ok     3
/N0/IB6/P1  SUNW,schizo      25   ok     3
/N0/IB7/P0  SUNW,schizo      26   ok     3
/N0/IB7/P1  SUNW,schizo      27   ok     3
/N0/IB6/P0  SUNW,sgsbbc      24   ok     2
/N0/IB7/P0  SUNW,sgsbbc      26   ok     2
# 

3) View from the system controller

v4u-6800a-sc1-gmp02:SC> showboards
Slot     Pwr Component Type                 State      Status     Domain
----     --- --------------                 -----      ------     ------
SSC1     On  System Controller              Main       Passed     -
SSC0     On  System Controller              Spare      -          -
ID0      On  Sun Fire 6800 Centerplane      -          OK         -
PS0      On  A152 Power Supply              -          OK         -
PS1      On  A152 Power Supply              -          OK         -
PS2      On  A152 Power Supply              -          OK         -
PS3      On  A152 Power Supply              -          OK         -
PS4      On  A152 Power Supply              -          OK         -
PS5      On  A152 Power Supply              -          OK         -
FT0      On  Fan Tray                       Low Speed  OK         -
FT1      On  Fan Tray                       Low Speed  OK         -
FT2      On  Fan Tray                       Low Speed  OK         -
FT3      On  Fan Tray                       Low Speed  OK         -
RP0      On  Repeater Board                 -          OK         -
RP1      On  Repeater Board                 -          OK         -
RP2      On  Repeater Board                 -          OK         -
RP3      On  Repeater Board                 -          OK         -
/N0/SB0  On  CPU Board V2                   Active     Passed     A
SB1 Off CPU Board V2 Available Not tested Isolated
SB2      On  CPU Board V2                   Available  Not tested Isolated
/N0/SB3  On  CPU Board V2                   Assigned   Not tested D
/N0/IB6  On  PCI I/O Board                  Active     Passed     A
/N0/IB7  On  PCI I/O Board                  Active     Passed     A
IB8      On  Fire Link/CPCI I/O Board       Available  Not tested Isolated
/N0/IB9  On  Fire Link/CPCI I/O Board       Assigned   Not tested D

4) Use cfgadm to determine the attachment point (AP) ID for system boards.

# /usr/sbin/cfgadm -l -s "select=class(sbd)"
Ap_Id                          Type         Receptacle   Occupant
Condition
N0.IB6                         PCI_I/O_Boa  connected    configured   ok
N0.IB7                         PCI_I/O_Boa  connected    configured   ok
N0.IB8                         Fire_Link/C  disconnected unconfigured unknown
N0.SB0                         CPU_V2       connected    configured   ok
N0.SB1 CPU_V2 disconnected unconfigured unknown
N0.SB2                         CPU_V2       disconnected unconfigured unknown
N0.SB4                         unknown      empty        unconfigured unknown
N0.SB5                         unknown      empty        unconfigured unknown
# 
# /usr/sbin/cfgadm -a
Ap_Id                          Type         Receptacle   Occupant
Condition
N0.IB6                         PCI_I/O_Boa  connected    configured   ok
N0.IB6::pci0                   io           connected    configured   ok
N0.IB6::pci1                   io           connected    configured   ok
N0.IB6::pci2                   io           connected    configured   ok
N0.IB6::pci3                   io           connected    configured   ok
N0.IB7                         PCI_I/O_Boa  connected    configured   ok
N0.IB7::pci0                   io           connected    configured   ok
N0.IB7::pci1                   io           connected    configured   ok
N0.IB7::pci2                   io           connected    configured   ok
N0.IB7::pci3                   io           connected    configured   ok
N0.IB8                         Fire_Link/C  disconnected unconfigured unknown
N0.SB0                         CPU_V2       connected    configured   ok
N0.SB0::cpu0                   cpu          connected    configured   ok
N0.SB0::cpu1                   cpu          connected    configured   ok
N0.SB0::cpu2                   cpu          connected    configured   ok
N0.SB0::cpu3                   cpu          connected    configured   ok
N0.SB0::memory                 memory       connected    configured   ok
N0.SB1 CPU_V2 disconnected unconfigured unknown
N0.SB2                         CPU_V2       disconnected unconfigured unknown
N0.SB4                         unknown      empty        unconfigured unknown
N0.SB5                         unknown      empty        unconfigured unknown
c0                             scsi-bus     connected    configured   unknown
c0::dsk/c0t0d0                 disk         connected    configured   unknown
c0::dsk/c0t1d0                 disk         connected    configured   unknown

NOTE: We will use dynamic Reconfiguration (DR) to attach SB1

5) If necessary Poweron SB1

v4u-6800a-sc1-gmp02:SC> poweron sb1
SB1: powered on
v4u-6800a-sc1-gmp02:SC> 
v4u-6800a-sc1-gmp02:SC> showboards
Slot     Pwr Component Type                 State      Status     Domain
----     --- --------------                 -----      ------     ------
SSC1     On  System Controller              Main       Passed     -
SSC0     On  System Controller              Spare      -          -
ID0      On  Sun Fire 6800 Centerplane      -          OK         -
PS0      On  A152 Power Supply              -          OK         -
PS1      On  A152 Power Supply              -          OK         -
PS2      On  A152 Power Supply              -          OK         -
PS3      On  A152 Power Supply              -          OK         -
PS4      On  A152 Power Supply              -          OK         -
PS5      On  A152 Power Supply              -          OK         -
FT0      On  Fan Tray                       Low Speed  OK         -
FT1      On  Fan Tray                       Low Speed  OK         -
FT2      On  Fan Tray                       Low Speed  OK         -
FT3      On  Fan Tray                       Low Speed  OK         -
RP0      On  Repeater Board                 -          OK         -
RP1      On  Repeater Board                 -          OK         -
RP2      On  Repeater Board                 -          OK         -
RP3      On  Repeater Board                 -          OK         -
/N0/SB0  On  CPU Board V2                   Active     Passed     A
SB1 On CPU Board V2 Available Not tested Isolated
SB2      On  CPU Board V2                   Available  Not tested Isolated
/N0/SB3  On  CPU Board V2                   Assigned   Not tested D
/N0/IB6  On  PCI I/O Board                  Active     Passed     A
/N0/IB7  On  PCI I/O Board                  Active     Passed     A
IB8      On  Fire Link/CPCI I/O Board       Available  Not tested Isolated
/N0/IB9  On  Fire Link/CPCI I/O Board       Assigned   Not tested D
v4u-6800a-sc1-gmp02:SC> 

6) Configure the domain from the system controller to use SB1.

Please be aware that the target SB to be added to the domain MUST be in the domain's Access Control List (ACL). This can be checked using the showplatform -v command on the platform shell. If modification is needed to the Domain's ACL, the platform shell command setupplatform should be used.

v4u-6800a-sc1-gmp02:SC> addboard -d a sb1
/N0/SB1: will be configured into the domain after setkeyswitch off/standby
DR can be used to configure /N0/SB1 into an active domain.
v4u-6800a-sc1-gmp02:SC> 
v4u-6800a-sc1-gmp02:SC> showboard
Slot     Pwr Component Type                 State      Status     Domain
----     --- --------------                 -----      ------     ------
SSC1     On  System Controller              Main       Passed     -
SSC0     On  System Controller              Spare      -          -
ID0      On  Sun Fire 6800 Centerplane      -          OK         -
PS0      On  A152 Power Supply              -          OK         -
PS1      On  A152 Power Supply              -          OK         -
PS2      On  A152 Power Supply              -          OK         -
PS3      On  A152 Power Supply              -          OK         -
PS4      On  A152 Power Supply              -          OK         -
PS5      On  A152 Power Supply              -          OK         -
FT0      On  Fan Tray                       Low Speed  OK         -
FT1      On  Fan Tray                       Low Speed  OK         -
FT2      On  Fan Tray                       Low Speed  OK         -
FT3      On  Fan Tray                       Low Speed  OK         -
RP0      On  Repeater Board                 -          OK         -
RP1      On  Repeater Board                 -          OK         -
RP2      On  Repeater Board                 -          OK         -
RP3      On  Repeater Board                 -          OK         -
/N0/SB0  On  CPU Board V2                   Active     Passed     A
/N0/SB1 On CPU Board V2 Assigned Not tested A
SB2      On  CPU Board V2                   Available  Not tested Isolated
/N0/SB3  On  CPU Board V2                   Assigned   Not tested D
/N0/IB6  On  PCI I/O Board                  Active     Passed     A
/N0/IB7  On  PCI I/O Board                  Active     Passed     A
IB8      On  Fire Link/CPCI I/O Board       Available  Not tested Isolated
/N0/IB9  On  Fire Link/CPCI I/O Board       Assigned   Not tested D
v4u-6800a-sc1-gmp02:SC> 

7) Run POST on the System Board to be added to the running domain:

# /usr/sbin/cfgadm -t N0.SB1
{/N0/SB1/P0} Running CPU POR and Set Clocks
{/N0/SB1/P2} Running CPU POR and Set Clocks
{/N0/SB1/P3} Running CPU POR and Set Clocks
{/N0/SB1/P1} Running CPU POR and Set Clocks
.....
.......
{/N0/SB1/P3} Subtest: Board Memory Interleave Configuration
{/N0/SB1/P0} Passed
{/N0/SB1/P1} Passed
{/N0/SB1/P2} Passed
{/N0/SB1/P3} Passed
{/N0/SB1/P0} DCB_ENTER_OBP command succeeded
{/N0/SB1/P1} DCB_ENTER_OBP command succeeded
{/N0/SB1/P2} DCB_ENTER_OBP command succeeded
{/N0/SB1/P3} DCB_ENTER_OBP command succeeded
# 

NOTE: Confirm there are no errors reported during this step.

8) Configure the domain using cfgadm to use SB1

# /usr/sbin/cfgadm -o platform=diag=init -c configure N0.SB1

9) Use cfgadm to verify the above operation

# /usr/sbin/cfgadm -a N0.SB1
Ap_Id                          Type         Receptacle   Occupant
Condition
N0.SB1                         CPU_V2       connected    configured   ok
N0.SB1::cpu0                   cpu          connected    configured   ok
N0.SB1::cpu1                   cpu          connected    configured   ok
N0.SB1::cpu2                   cpu          connected    configured   ok
N0.SB1::cpu3                   cpu          connected    configured   ok
N0.SB1::memory                 memory       connected    configured   ok
# 
# /usr/sbin/cfgadm -av N0.SB1
Ap_Id                          Receptacle   Occupant     Condition  Information
When         Type         Busy     Phys_Id
N0.SB1                         connected    configured   ok         powered-on, assigned
Feb 11 16:54 CPU_V2       n        /devices/ssm@0,0:N0.SB1
N0.SB1::cpu0                   connected    configured   ok         cpuid 4, speed 1050 MHz, ecache 8 MBytes
Feb 11 16:54 cpu          n        /devices/ssm@0,0:N0.SB1::cpu0
N0.SB1::cpu1                   connected    configured   ok         cpuid 5, speed 1050 MHz, ecache 8 MBytes
Feb 11 16:54 cpu          n        /devices/ssm@0,0:N0.SB1::cpu1
N0.SB1::cpu2                   connected    configured   ok         cpuid 6, speed 1050 MHz, ecache 8 MBytes
Feb 11 16:54 cpu          n        /devices/ssm@0,0:N0.SB1::cpu2
N0.SB1::cpu3                   connected    configured   ok         cpuid 7, speed 1050 MHz, ecache 8 MBytes
Feb 11 16:54 cpu          n        /devices/ssm@0,0:N0.SB1::cpu3
N0.SB1::memory                 connected    configured   ok         base address 0x2000000000, 33554432 KBytes total
Feb 11 16:54 memory       n        /devices/ssm@0,0:N0.SB1::memory

10) Confirm the domain can see the new CPUs

# /usr/sbin/psrinfo
0       on-line   since 02/11/04 15:54:11
1       on-line   since 02/11/04 15:54:12
2       on-line   since 02/11/04 15:54:12
3       on-line   since 02/11/04 15:54:12
4       on-line   since 02/11/04 16:54:37
5       on-line   since 02/11/04 16:54:37
6       on-line   since 02/11/04 16:54:37
7       on-line   since 02/11/04 16:54:37
# 

11) Confirm the additional memory is available.

# /usr/sbin/prtconf | more
System Configuration:  Sun Microsystems  sun4u
Memory size: 49152 Megabytes
System Peripherals (Software Nodes):
SUNW,Sun-Fire

12) Use prtdiag to verify the new configuration.

# cd /usr/platform/`uname -i`/sbin
# ./prtdiag
System Configuration:  Sun Microsystems  sun4u Sun Fire 6800
System clock frequency: 150 MHz
Memory size: 49152 Megabytes
========================= CPUs ===============================================
            Port  Run    E$   CPU      CPU
FRU Name     ID   MHz    MB   Impl.    Mask
----------  ----  ----  ----  -------  ----
/N0/SB0/P0    0   1050   8.0  US-III+  2.3
/N0/SB0/P1    1   1050   8.0  US-III+  2.3
/N0/SB0/P2    2   1050   8.0  US-III+  2.3
/N0/SB0/P3    3   1050   8.0  US-III+  2.3
/N0/SB1/P0 4 1050 8.0 US-III+ 2.3 /N0/SB1/P1 5 1050 8.0 US-III+ 2.3 /N0/SB1/P2 6 1050 8.0 US-III+ 2.3 /N0/SB1/P3 7 1050 8.0 US-III+ 2.3  
========================= Memory Configuration ===============================
                     Logical  Logical  Logical
               Port  Bank     Bank     Bank         DIMM    Interleave  Interleave
FRU Name        ID   Num      Size     Status       Size    Factor      Segment
-------------  ----  ----     ------   -----------  ------  ----------  ----------
/N0/SB0/P0/B0    0    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P0/B1    0    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P0/B0    0    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P0/B1    0    3      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B0    1    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B1    1    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B0    1    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P1/B1    1    3      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B0    2    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B1    2    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B0    2    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P2/B1    2    3      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B0    3    0      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B1    3    1      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B0    3    2      1024MB    pass          512MB    16-way       0
/N0/SB0/P3/B1    3    3      1024MB    pass          512MB    16-way       0
/N0/SB1/P0/B0 4 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P0/B1 4 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P0/B0 4 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P0/B1 4 3 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B0 5 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B1 5 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B0 5 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B1 5 3 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B0 6 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B1 6 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B0 6 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B1 6 3 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B0 7 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B1 7 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B0 7 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B1 7 3 2048MB pass 1024MB 16-way 1
========================= IO Cards =========================
                                Bus  Max                                  
            IO   Port Bus       Freq Bus  Dev,                            
FRU Name    Type  ID  Side Slot MHz  Freq Func State Name                              Model
----------  ---- ---- ---- ---- ---- ---- ---- ----- --------------------------------  ----------------------
/N0/IB6/P0  PCI   24   B    0    33   33  1,0  ok    pci-pci1011,24.3/pci108e,1000     pci-bridge  
/N0/IB6/P0  PCI   24   B    0    33   33  0,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB6/P0  PCI   24   B    0    33   33  0,1  ok    SUNW,hme-pci108e,1001             SUNW,cheerio
/N0/IB6/P0  PCI   24   B    0    33   33  4,0  ok    SUNW,isptwo-pci1077,1020/sd (blo+ QLGC,ISP1040B
/N0/IB6/P0  PCI   24   B    1    33   33  2,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB6/P0  PCI   24   B    1    33   33  2,1  ok    SUNW,hme-pci108e,1001             SUNW,qsi-cheerio
/N0/IB6/P1  PCI   25   B    5    33   33  2,0  ok    JNI,FCR/sd (block)                FCE-6460-N    
/N0/IB7/P0  PCI   26   B    1    33   33  2,0  ok    pci-pci1011,25.4/pci108e,1000     pci-bridge  
/N0/IB7/P0  PCI   26   B    1    33   33  0,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  0,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    1    33   33  1,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  1,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    1    33   33  2,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  2,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    1    33   33  3,0  ok    pci108e,1000-pci108e,1000.1                          
/N0/IB7/P0  PCI   26   B    1    33   33  3,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe
/N0/IB7/P0  PCI   26   B    2    33   33  3,0  ok    SUNW,qlc-pci1077,2200.1077.4082.+            
========================= Active Boards for Domain ===========================
          Power  Fault  HotPlug  Board
FRU Name   LED    LED     LED    Cond.
--------  -----  -----  -------  -------
/N0/SB0   on     off    off      ok
/N0/SB1   on     off    off      ok
/N0/IB6   on     off    off      ok
/N0/IB7   on     off    off      ok       
========================= Available Boards/Slots for Domain ==================
          Power  Fault  HotPlug  Board/Slot  Board/Slot
FRU Name   LED    LED     LED    Condition   Assigned
--------  -----  -----  -------  ----------  ----------
/SB2      on     off    off      Unknown     no
/SB4      off    off    off      Empty       yes
/SB5      off    off    off      Empty       yes
/IB8      on     off    off      Unknown     no  
========================= Hardware Failures ==================================
No Hardware failures found in System
# 

13) Check /var/adm/messages for confirmation

# cat /var/adm/messages
.....
......
Feb 11 16:54:24 v4u-6800a-doma-gmp02 unix: [ID 882636 kern.warning] WARNING: interrupt level 6 not serviced
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu4: (upaid 4 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu5: (upaid 5 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu6: (upaid 6 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu7: (upaid 7 impl 0x15 ver 0x23 clock 1050 MHz)
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 4 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 5 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 6 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 7 initialization complete - restarted
Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 700753 kern.info] kphysm_add_memory_dynamic: adding 33554432K at 0x2000000000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 unix: [ID 323408 kern.info] kphysm_add_memory_dynamic: mem = 50331648K (0xc00000000)
Feb 11 16:54:52 v4u-6800a-doma-gmp02 unix: [ID 401001 kern.info] kphysm_add_memory_dynamic: avail mem = 50328207360
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller4 at ssm0: Node 0 Safari id 4 0x2400000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us34 is /ssm@0,0/memory-controller@4,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@4,400000 (mc-us34) online
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller5 at ssm0: Node 0 Safari id 5 0x2c00000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us35 is /ssm@0,0/memory-controller@5,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@5,400000 (mc-us35) online
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller6 at ssm0: Node 0 Safari id 6 0x3400000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us36 is /ssm@0,0/memory-controller@6,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@6,400000 (mc-us36) online
Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller7 at ssm0: Node 0 Safari id 7 0x3c00000 ...
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us37 is /ssm@0,0/memory-controller@7,400000
Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@7,400000 (mc-us37) online
#



Product
Sun Fire 6800 Server
Sun Fire 4800 Server
Sun Fire 3800 Server

Keywords: DR, Dynamic Reconfiguration, 3800, 4800, 6800, addboard
Previously Published As 74808


Attachments
This solution has no attachment