![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1006136.1 : Sun Fire[TM] V1280/E2900/3800/4800/4810/6800/E4900/E6900 & Netra 1280/1290: How to add CPUs and System Boards to a running domain
PreviouslyPublishedAs 208592 Applies to:Sun Fire 3800 Server - Version All Versions and laterSun Netra 1290 Server - Version All Versions and later Sun Fire 6800 Server - Version All Versions and later Sun Netra 1280 Server - Version All Versions and later Sun Fire E2900 Server - Version All Versions and later All Platforms GoalUtilizing Dynamic Reconfiguration (DR) or cfgadm to add a System Board to a domain. SolutionThe example procedure below is on a 6800 server and the board being added is SB1. 1) Make a note of the number of CPUs on the server for comparison purposes once the CPUs have been added # /usr/sbin/psrinfo 0 on-line since 02/11/04 15:54:11 1 on-line since 02/11/04 15:54:12 2 on-line since 02/11/04 15:54:12 3 on-line since 02/11/04 15:54:12 # 2) Make a note of the current memory on the server, again, for comparison purposes # cd /usr/platform/`uname -i`/sbin # ./prtdiag -v System Configuration: Sun Microsystems sun4u Sun Fire 6800 System clock frequency: 150 MHz Memory size: 16384 Megabytes ========================= CPUs =============================================== Port Run E$ CPU CPU FRU Name ID MHz MB Impl. Mask ---------- ---- ---- ---- ------- ---- /N0/SB0/P0 0 1050 8.0 US-III+ 2.3 /N0/SB0/P1 1 1050 8.0 US-III+ 2.3 /N0/SB0/P2 2 1050 8.0 US-III+ 2.3 /N0/SB0/P3 3 1050 8.0 US-III+ 2.3 ========================= Memory Configuration =============================== Logical Logical Logical Port Bank Bank Bank DIMM Interleave Interleave FRU Name ID Num Size Status Size Factor Segment ------------- ---- ---- ------ ----------- ------ ---------- ---------- /N0/SB0/P0/B0 0 0 1024MB pass 512MB 16-way 0 /N0/SB0/P0/B1 0 1 1024MB pass 512MB 16-way 0 /N0/SB0/P0/B0 0 2 1024MB pass 512MB 16-way 0 /N0/SB0/P0/B1 0 3 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B0 1 0 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B1 1 1 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B0 1 2 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B1 1 3 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B0 2 0 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B1 2 1 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B0 2 2 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B1 2 3 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B0 3 0 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B1 3 1 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B0 3 2 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B1 3 3 1024MB pass 512MB 16-way 0 ========================= IO Cards ========================= Bus Max IO Port Bus Freq Bus Dev, FRU Name Type ID Side Slot MHz Freq Func State Name Model ---------- ---- ---- ---- ---- ---- ---- ---- ----- -------------------------------- ---------------------- /N0/IB6/P0 PCI 24 B 0 33 33 1,0 ok pci-pci1011,24.3/pci108e,1000 pci-bridge /N0/IB6/P0 PCI 24 B 0 33 33 0,0 ok pci108e,1000-pci108e,1000.1 /N0/IB6/P0 PCI 24 B 0 33 33 0,1 ok SUNW,hme-pci108e,1001 SUNW,cheerio /N0/IB6/P0 PCI 24 B 0 33 33 4,0 ok SUNW,isptwo-pci1077,1020/sd (blo+ QLGC,ISP1040B /N0/IB6/P0 PCI 24 B 1 33 33 2,0 ok pci108e,1000-pci108e,1000.1 /N0/IB6/P0 PCI 24 B 1 33 33 2,1 ok SUNW,hme-pci108e,1001 SUNW,qsi-cheerio /N0/IB6/P1 PCI 25 B 5 33 33 2,0 ok JNI,FCR/sd (block) FCE-6460-N /N0/IB7/P0 PCI 26 B 1 33 33 2,0 ok pci-pci1011,25.4/pci108e,1000 pci-bridge /N0/IB7/P0 PCI 26 B 1 33 33 0,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 0,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 1 33 33 1,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 1,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 1 33 33 2,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 2,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 1 33 33 3,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 3,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 2 33 33 3,0 ok SUNW,qlc-pci1077,2200.1077.4082.+ ========================= Active Boards for Domain =========================== Power Fault HotPlug Board FRU Name LED LED LED Cond. -------- ----- ----- ------- ------- /N0/SB0 on off off ok /N0/IB6 on off off ok /N0/IB7 on off off ok ========================= Available Boards/Slots for Domain ================== Power Fault HotPlug Board/Slot Board/Slot FRU Name LED LED LED Condition Assigned -------- ----- ----- ------- ---------- ---------- /SB1 off off on Unknown no /SB2 on off off Unknown no /SB4 off off off Empty yes /SB5 off off off Empty yes /IB8 on off off Unknown no ========================= Hardware Failures ================================== No Hardware failures found in System ========================= HW Revisions ======================================= System PROM revisions: ---------------------- OBP 5.15.1 05/29/03 17:05 IO ASIC revisions: ------------------ Port FRU Name Model ID Status Version ----------- --------------- ---- ------ ------- /N0/IB6/P0 SUNW,schizo 24 ok 3 /N0/IB6/P1 SUNW,schizo 25 ok 3 /N0/IB7/P0 SUNW,schizo 26 ok 3 /N0/IB7/P1 SUNW,schizo 27 ok 3 /N0/IB6/P0 SUNW,sgsbbc 24 ok 2 /N0/IB7/P0 SUNW,sgsbbc 26 ok 2 # 3) View from the system controller v4u-6800a-sc1-gmp02:SC> showboards Slot Pwr Component Type State Status Domain ---- --- -------------- ----- ------ ------ SSC1 On System Controller Main Passed - SSC0 On System Controller Spare - - ID0 On Sun Fire 6800 Centerplane - OK - PS0 On A152 Power Supply - OK - PS1 On A152 Power Supply - OK - PS2 On A152 Power Supply - OK - PS3 On A152 Power Supply - OK - PS4 On A152 Power Supply - OK - PS5 On A152 Power Supply - OK - FT0 On Fan Tray Low Speed OK - FT1 On Fan Tray Low Speed OK - FT2 On Fan Tray Low Speed OK - FT3 On Fan Tray Low Speed OK - RP0 On Repeater Board - OK - RP1 On Repeater Board - OK - RP2 On Repeater Board - OK - RP3 On Repeater Board - OK - /N0/SB0 On CPU Board V2 Active Passed A SB1 Off CPU Board V2 Available Not tested Isolated SB2 On CPU Board V2 Available Not tested Isolated /N0/SB3 On CPU Board V2 Assigned Not tested D /N0/IB6 On PCI I/O Board Active Passed A /N0/IB7 On PCI I/O Board Active Passed A IB8 On Fire Link/CPCI I/O Board Available Not tested Isolated /N0/IB9 On Fire Link/CPCI I/O Board Assigned Not tested D 4) Use cfgadm to determine the attachment point (AP) ID for system boards. # /usr/sbin/cfgadm -l -s "select=class(sbd)" Ap_Id Type Receptacle Occupant Condition N0.IB6 PCI_I/O_Boa connected configured ok N0.IB7 PCI_I/O_Boa connected configured ok N0.IB8 Fire_Link/C disconnected unconfigured unknown N0.SB0 CPU_V2 connected configured ok N0.SB1 CPU_V2 disconnected unconfigured unknown N0.SB2 CPU_V2 disconnected unconfigured unknown N0.SB4 unknown empty unconfigured unknown N0.SB5 unknown empty unconfigured unknown # # /usr/sbin/cfgadm -a Ap_Id Type Receptacle Occupant Condition N0.IB6 PCI_I/O_Boa connected configured ok N0.IB6::pci0 io connected configured ok N0.IB6::pci1 io connected configured ok N0.IB6::pci2 io connected configured ok N0.IB6::pci3 io connected configured ok N0.IB7 PCI_I/O_Boa connected configured ok N0.IB7::pci0 io connected configured ok N0.IB7::pci1 io connected configured ok N0.IB7::pci2 io connected configured ok N0.IB7::pci3 io connected configured ok N0.IB8 Fire_Link/C disconnected unconfigured unknown N0.SB0 CPU_V2 connected configured ok N0.SB0::cpu0 cpu connected configured ok N0.SB0::cpu1 cpu connected configured ok N0.SB0::cpu2 cpu connected configured ok N0.SB0::cpu3 cpu connected configured ok N0.SB0::memory memory connected configured ok N0.SB1 CPU_V2 disconnected unconfigured unknown N0.SB2 CPU_V2 disconnected unconfigured unknown N0.SB4 unknown empty unconfigured unknown N0.SB5 unknown empty unconfigured unknown c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::dsk/c0t1d0 disk connected configured unknown NOTE: We will use dynamic Reconfiguration (DR) to attach SB1 5) If necessary Poweron SB1 v4u-6800a-sc1-gmp02:SC> poweron sb1 SB1: powered on v4u-6800a-sc1-gmp02:SC> v4u-6800a-sc1-gmp02:SC> showboards Slot Pwr Component Type State Status Domain ---- --- -------------- ----- ------ ------ SSC1 On System Controller Main Passed - SSC0 On System Controller Spare - - ID0 On Sun Fire 6800 Centerplane - OK - PS0 On A152 Power Supply - OK - PS1 On A152 Power Supply - OK - PS2 On A152 Power Supply - OK - PS3 On A152 Power Supply - OK - PS4 On A152 Power Supply - OK - PS5 On A152 Power Supply - OK - FT0 On Fan Tray Low Speed OK - FT1 On Fan Tray Low Speed OK - FT2 On Fan Tray Low Speed OK - FT3 On Fan Tray Low Speed OK - RP0 On Repeater Board - OK - RP1 On Repeater Board - OK - RP2 On Repeater Board - OK - RP3 On Repeater Board - OK - /N0/SB0 On CPU Board V2 Active Passed A SB1 On CPU Board V2 Available Not tested Isolated SB2 On CPU Board V2 Available Not tested Isolated /N0/SB3 On CPU Board V2 Assigned Not tested D /N0/IB6 On PCI I/O Board Active Passed A /N0/IB7 On PCI I/O Board Active Passed A IB8 On Fire Link/CPCI I/O Board Available Not tested Isolated /N0/IB9 On Fire Link/CPCI I/O Board Assigned Not tested D v4u-6800a-sc1-gmp02:SC> 6) Configure the domain from the system controller to use SB1. Please be aware that the target SB to be added to the domain MUST be in the domain's Access Control List (ACL). This can be checked using the showplatform -v command on the platform shell. If modification is needed to the Domain's ACL, the platform shell command setupplatform should be used. v4u-6800a-sc1-gmp02:SC> addboard -d a sb1 /N0/SB1: will be configured into the domain after setkeyswitch off/standby DR can be used to configure /N0/SB1 into an active domain. v4u-6800a-sc1-gmp02:SC> v4u-6800a-sc1-gmp02:SC> showboard Slot Pwr Component Type State Status Domain ---- --- -------------- ----- ------ ------ SSC1 On System Controller Main Passed - SSC0 On System Controller Spare - - ID0 On Sun Fire 6800 Centerplane - OK - PS0 On A152 Power Supply - OK - PS1 On A152 Power Supply - OK - PS2 On A152 Power Supply - OK - PS3 On A152 Power Supply - OK - PS4 On A152 Power Supply - OK - PS5 On A152 Power Supply - OK - FT0 On Fan Tray Low Speed OK - FT1 On Fan Tray Low Speed OK - FT2 On Fan Tray Low Speed OK - FT3 On Fan Tray Low Speed OK - RP0 On Repeater Board - OK - RP1 On Repeater Board - OK - RP2 On Repeater Board - OK - RP3 On Repeater Board - OK - /N0/SB0 On CPU Board V2 Active Passed A /N0/SB1 On CPU Board V2 Assigned Not tested A SB2 On CPU Board V2 Available Not tested Isolated /N0/SB3 On CPU Board V2 Assigned Not tested D /N0/IB6 On PCI I/O Board Active Passed A /N0/IB7 On PCI I/O Board Active Passed A IB8 On Fire Link/CPCI I/O Board Available Not tested Isolated /N0/IB9 On Fire Link/CPCI I/O Board Assigned Not tested D v4u-6800a-sc1-gmp02:SC> 7) Run POST on the System Board to be added to the running domain: # /usr/sbin/cfgadm -t N0.SB1 {/N0/SB1/P0} Running CPU POR and Set Clocks {/N0/SB1/P2} Running CPU POR and Set Clocks {/N0/SB1/P3} Running CPU POR and Set Clocks {/N0/SB1/P1} Running CPU POR and Set Clocks ..... ....... {/N0/SB1/P3} Subtest: Board Memory Interleave Configuration {/N0/SB1/P0} Passed {/N0/SB1/P1} Passed {/N0/SB1/P2} Passed {/N0/SB1/P3} Passed {/N0/SB1/P0} DCB_ENTER_OBP command succeeded {/N0/SB1/P1} DCB_ENTER_OBP command succeeded {/N0/SB1/P2} DCB_ENTER_OBP command succeeded {/N0/SB1/P3} DCB_ENTER_OBP command succeeded # NOTE: Confirm there are no errors reported during this step. 8) Configure the domain using cfgadm to use SB1 # /usr/sbin/cfgadm -o platform=diag=init -c configure N0.SB1 9) Use cfgadm to verify the above operation # /usr/sbin/cfgadm -a N0.SB1 Ap_Id Type Receptacle Occupant Condition N0.SB1 CPU_V2 connected configured ok N0.SB1::cpu0 cpu connected configured ok N0.SB1::cpu1 cpu connected configured ok N0.SB1::cpu2 cpu connected configured ok N0.SB1::cpu3 cpu connected configured ok N0.SB1::memory memory connected configured ok # # /usr/sbin/cfgadm -av N0.SB1 Ap_Id Receptacle Occupant Condition Information When Type Busy Phys_Id N0.SB1 connected configured ok powered-on, assigned Feb 11 16:54 CPU_V2 n /devices/ssm@0,0:N0.SB1 N0.SB1::cpu0 connected configured ok cpuid 4, speed 1050 MHz, ecache 8 MBytes Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu0 N0.SB1::cpu1 connected configured ok cpuid 5, speed 1050 MHz, ecache 8 MBytes Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu1 N0.SB1::cpu2 connected configured ok cpuid 6, speed 1050 MHz, ecache 8 MBytes Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu2 N0.SB1::cpu3 connected configured ok cpuid 7, speed 1050 MHz, ecache 8 MBytes Feb 11 16:54 cpu n /devices/ssm@0,0:N0.SB1::cpu3 N0.SB1::memory connected configured ok base address 0x2000000000, 33554432 KBytes total Feb 11 16:54 memory n /devices/ssm@0,0:N0.SB1::memory 10) Confirm the domain can see the new CPUs # /usr/sbin/psrinfo 0 on-line since 02/11/04 15:54:11 1 on-line since 02/11/04 15:54:12 2 on-line since 02/11/04 15:54:12 3 on-line since 02/11/04 15:54:12 4 on-line since 02/11/04 16:54:37 5 on-line since 02/11/04 16:54:37 6 on-line since 02/11/04 16:54:37 7 on-line since 02/11/04 16:54:37 # 11) Confirm the additional memory is available. # /usr/sbin/prtconf | more System Configuration: Sun Microsystems sun4u Memory size: 49152 Megabytes System Peripherals (Software Nodes): SUNW,Sun-Fire 12) Use prtdiag to verify the new configuration. # cd /usr/platform/`uname -i`/sbin # ./prtdiag System Configuration: Sun Microsystems sun4u Sun Fire 6800 System clock frequency: 150 MHz Memory size: 49152 Megabytes ========================= CPUs =============================================== Port Run E$ CPU CPU FRU Name ID MHz MB Impl. Mask ---------- ---- ---- ---- ------- ---- /N0/SB0/P0 0 1050 8.0 US-III+ 2.3 /N0/SB0/P1 1 1050 8.0 US-III+ 2.3 /N0/SB0/P2 2 1050 8.0 US-III+ 2.3 /N0/SB0/P3 3 1050 8.0 US-III+ 2.3 /N0/SB1/P0 4 1050 8.0 US-III+ 2.3 /N0/SB1/P1 5 1050 8.0 US-III+ 2.3 /N0/SB1/P2 6 1050 8.0 US-III+ 2.3 /N0/SB1/P3 7 1050 8.0 US-III+ 2.3 ========================= Memory Configuration =============================== Logical Logical Logical Port Bank Bank Bank DIMM Interleave Interleave FRU Name ID Num Size Status Size Factor Segment ------------- ---- ---- ------ ----------- ------ ---------- ---------- /N0/SB0/P0/B0 0 0 1024MB pass 512MB 16-way 0 /N0/SB0/P0/B1 0 1 1024MB pass 512MB 16-way 0 /N0/SB0/P0/B0 0 2 1024MB pass 512MB 16-way 0 /N0/SB0/P0/B1 0 3 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B0 1 0 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B1 1 1 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B0 1 2 1024MB pass 512MB 16-way 0 /N0/SB0/P1/B1 1 3 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B0 2 0 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B1 2 1 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B0 2 2 1024MB pass 512MB 16-way 0 /N0/SB0/P2/B1 2 3 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B0 3 0 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B1 3 1 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B0 3 2 1024MB pass 512MB 16-way 0 /N0/SB0/P3/B1 3 3 1024MB pass 512MB 16-way 0 /N0/SB1/P0/B0 4 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P0/B1 4 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P0/B0 4 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P0/B1 4 3 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B0 5 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B1 5 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B0 5 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P1/B1 5 3 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B0 6 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B1 6 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B0 6 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P2/B1 6 3 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B0 7 0 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B1 7 1 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B0 7 2 2048MB pass 1024MB 16-way 1 /N0/SB1/P3/B1 7 3 2048MB pass 1024MB 16-way 1 ========================= IO Cards ========================= Bus Max IO Port Bus Freq Bus Dev, FRU Name Type ID Side Slot MHz Freq Func State Name Model ---------- ---- ---- ---- ---- ---- ---- ---- ----- -------------------------------- ---------------------- /N0/IB6/P0 PCI 24 B 0 33 33 1,0 ok pci-pci1011,24.3/pci108e,1000 pci-bridge /N0/IB6/P0 PCI 24 B 0 33 33 0,0 ok pci108e,1000-pci108e,1000.1 /N0/IB6/P0 PCI 24 B 0 33 33 0,1 ok SUNW,hme-pci108e,1001 SUNW,cheerio /N0/IB6/P0 PCI 24 B 0 33 33 4,0 ok SUNW,isptwo-pci1077,1020/sd (blo+ QLGC,ISP1040B /N0/IB6/P0 PCI 24 B 1 33 33 2,0 ok pci108e,1000-pci108e,1000.1 /N0/IB6/P0 PCI 24 B 1 33 33 2,1 ok SUNW,hme-pci108e,1001 SUNW,qsi-cheerio /N0/IB6/P1 PCI 25 B 5 33 33 2,0 ok JNI,FCR/sd (block) FCE-6460-N /N0/IB7/P0 PCI 26 B 1 33 33 2,0 ok pci-pci1011,25.4/pci108e,1000 pci-bridge /N0/IB7/P0 PCI 26 B 1 33 33 0,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 0,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 1 33 33 1,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 1,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 1 33 33 2,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 2,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 1 33 33 3,0 ok pci108e,1000-pci108e,1000.1 /N0/IB7/P0 PCI 26 B 1 33 33 3,1 ok SUNW,qfe-pci108e,1001 SUNW,pci-qfe /N0/IB7/P0 PCI 26 B 2 33 33 3,0 ok SUNW,qlc-pci1077,2200.1077.4082.+ ========================= Active Boards for Domain =========================== Power Fault HotPlug Board FRU Name LED LED LED Cond. -------- ----- ----- ------- ------- /N0/SB0 on off off ok /N0/SB1 on off off ok /N0/IB6 on off off ok /N0/IB7 on off off ok ========================= Available Boards/Slots for Domain ================== Power Fault HotPlug Board/Slot Board/Slot FRU Name LED LED LED Condition Assigned -------- ----- ----- ------- ---------- ---------- /SB2 on off off Unknown no /SB4 off off off Empty yes /SB5 off off off Empty yes /IB8 on off off Unknown no ========================= Hardware Failures ================================== No Hardware failures found in System # 13) Check /var/adm/messages for confirmation # cat /var/adm/messages ..... ...... Feb 11 16:54:24 v4u-6800a-doma-gmp02 unix: [ID 882636 kern.warning] WARNING: interrupt level 6 not serviced Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu4: (upaid 4 impl 0x15 ver 0x23 clock 1050 MHz) Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu5: (upaid 5 impl 0x15 ver 0x23 clock 1050 MHz) Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu6: (upaid 6 impl 0x15 ver 0x23 clock 1050 MHz) Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 987524 kern.info] cpu7: (upaid 7 impl 0x15 ver 0x23 clock 1050 MHz) Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 4 initialization complete - restarted Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 5 initialization complete - restarted Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 6 initialization complete - restarted Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 519443 kern.info] cpu 7 initialization complete - restarted Feb 11 16:54:37 v4u-6800a-doma-gmp02 unix: [ID 700753 kern.info] kphysm_add_memory_dynamic: adding 33554432K at 0x2000000000 Feb 11 16:54:52 v4u-6800a-doma-gmp02 unix: [ID 323408 kern.info] kphysm_add_memory_dynamic: mem = 50331648K (0xc00000000) Feb 11 16:54:52 v4u-6800a-doma-gmp02 unix: [ID 401001 kern.info] kphysm_add_memory_dynamic: avail mem = 50328207360 Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller4 at ssm0: Node 0 Safari id 4 0x2400000 ... Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us34 is /ssm@0,0/memory-controller@4,400000 Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@4,400000 (mc-us34) online Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller5 at ssm0: Node 0 Safari id 5 0x2c00000 ... Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us35 is /ssm@0,0/memory-controller@5,400000 Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@5,400000 (mc-us35) online Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller6 at ssm0: Node 0 Safari id 6 0x3400000 ... Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us36 is /ssm@0,0/memory-controller@6,400000 Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@6,400000 (mc-us36) online Feb 11 16:54:52 v4u-6800a-doma-gmp02 ssm: [ID 349649 kern.info] memory-controller7 at ssm0: Node 0 Safari id 7 0x3c00000 ... Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 936769 kern.info] mc-us37 is /ssm@0,0/memory-controller@7,400000 Feb 11 16:54:52 v4u-6800a-doma-gmp02 genunix: [ID 408114 kern.info] /ssm@0, 0/memory-controller@7,400000 (mc-us37) online #
Attachments This solution has no attachment |
||||||||||||
|