Solution Type Technical Instruction Sure Solution 1005533.1 : How to verify network connectivity on an X64 platform
PreviouslyPublishedAs 207663 Applies to:Sun Fire X4100 M2 Server - Version All Versions and laterSun Fire X4100 Server - Version All Versions and later Sun Fire X4200 M2 Server - Version All Versions and later Sun 3rd Party Software Product - Version Not Applicable and later Solaris Operating System - Version 9 GA and later All Platforms GoalTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems
This document provides information on how to to verify network connectivity on X64 platform with Solaris, Linux or Windows installed. Symptoms - lost network SolutionSteps to Follow NOTE: Console access is required to perform this activity, console redirection can be used on a X64 Server. Workstations have to connected to a keyboard and a monitor. Network connectivity is checked in two steps:
Physical connectionThe first thing to note is that there are usually a number of ethernet connections on an x64 server - x64 servers are equipped with ethernet sockets for the management console. Make sure that the cable is connected to the appropriate socket. Consider the diagram of a v20z in the attachment. There are four ethrnet connection - two for the Service processor and two for the platform (and this is before any additional PCI cards are installed with ethernet ports on them. Make sure you are connected to the right port.Device mappings are listed below. which will help identify which port you should be connected to. Check ethernet cables are correctly and securely attached and the link led indicates a connection (an established link is indicated by the right led). Check ethernet cables for damage. Replace faulty cables - CAT 5 cables provided performance of up to 100 MHz and are frequently used on 100 Mbit/s ethernet networks. Cat 6 provides performance of up to 250 MHz and is a cable standard for Gigabit Ethernet. Network drivers and how to check their availabilityYou will need to verify that the OS has recognised the device and the device is handled by an appropriate driver. You will also need to verify that the appropriate driver is loaded and the OS detects the link and the device is suitably configured for the network infrastructure. Examples on how to do this are outlined below against the different x64 platforms.
Checking your Network configurationVerify that the OS has recognised the device and the device is handled by an appropriate driver. Verify that the appropriate driver is loaded and the OS detects the link. Verify that the device is configured suitable for the network infrastructure.
Basic information about the network infrastucture are required. IP address assignment (static / dynamic (dhcp)) Other information about the network infrastructure is useful. Type of nameservice: (NIS, NIS+, DNS, LDAP, WINS, Active Directory) Use IP Addresses for all diagnostics, wrong configured nameservices cause timeouts and failing commands. Checking your network on Solaris 10 systemsUse the command dladm to check driver and link. # dladm show-dev nge0 link: up speed: 100 Mbps duplex: full nge1 link: unknown speed: 0 Mbps duplex: unknown e1000g0 link: down speed: 0 Mbps duplex: half e1000g1 link: down speed: 0 Mbps duplex: half Verify that your ethernet device is configured with an appropriate IP Address and is UP and RUNNING with the command ifconfig. # ifconfig -a lo0: flags=2001000849<up,loopback,running,multicast,ipv4,virtual> mtu 8232 index 1 inet 127.0.0.1 netmask ff000000 nge0: flags=1000843<up,broadcast,running,multicast,ipv4> mtu 1500 index 2 inet 129.157.39.13 netmask ffffff00 broadcast 129.157.39.255 Configure your ethernet device if necessary. # ifconfig nge0 plumb '''# ifconfig nge0 dhcp ''' or # ifconfig nge0 netmask 255.255.255.0 129.157.39.13 up Verify that other hosts are reachable with the command ping. # ping 10.16.8.72 10.16.8.72 is alive # ping 10.16.8.73 no answer from 10.16.8.73 Ping the the system from a other host and watch the IP traffic on the X64 system with snoop. A successful ping has a request and a reply. # snoop -r host 129.157.39.13 10.16.8.72 -> 129.157.39.13 ICMP Echo request (ID: 42813 Sequence number: 1) 129.157.39.13 -> 10.16.8.72 ICMP Echo reply (ID: 42813 Sequence number: 1) Verify the routing table when only a request is recognized. # netstat -rn Routing Table: IPv4 Destination Gateway Flags Ref Use Interface -------------------- -------------------- ----- ----- ---------- --------- default 129.157.39.250 UG 1 13 eri0 129.157.39.0 129.157.39.13 U 1 3010 eri0 224.0.0.0 129.157.39.13 U 1 0 eri0 127.0.0.1 127.0.0.1 UH 3 457 lo0 Set the default gateway if necessary. # route add default 129.157.39.250 Ping your default gateway on the X64 System. # ping 129.157.39.250 129.157.39.250 is alive Document 1017986.1 Cant connect to server may also be of assistance At this point, if you followed each troubleshooting step above you have collected the needed information for further troubleshooting. For additional support contact Sun Support. Checking your network on Linux SystemsUse the command ethtool to check driver and link. # ethtool -i eth0 driver: tg3 version: 3.81.1 firmware-version: 5703-v2.35 bus-info: 0000:02:02.0 Load the driver for the device if ethtool -i eth0 fails. Use modprobe -v where diver is e1000, forcedeth, tg3 or bcm5700. # modprobe -v tg3 insmod /lib/modules/2.6.23.8-34/kernel/drivers/net/tg3.ko Check the kernel ring buffer for successfully load. # dmesg | tail -n20 tg3.c:v3.81.1 (October 18, 2007) ACPI: PCI Interrupt 0000:02:02.0[A] -> GSI 25 (level, low) -> IRQ 25 eth0: Tigon3 [partno(BCM95703A30) rev 1002 PHY(5703)] (PCIX:66MHz:64-bit) 10/100/1000Base-T Ethernet 00:09:3d:10:51:26 eth0: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] WireSpeed[1] TSOcap[1] eth0: dma_rwctrl[769c0000] dma_mask[64-bit] ACPI: PCI Interrupt 0000:02:03.0[A] -> GSI 26 (level, low) -> IRQ 26 eth1: Tigon3 [partno(BCM95703A30) rev 1002 PHY(5703)] (PCIX:66MHz:64-bit) 10/100/1000Base-T Ethernet 00:09:3d:10:51:27 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] WireSpeed[1] TSOcap[1] eth1: dma_rwctrl[769c0000] dma_mask[64-bit] # ethtool eth0 Settings for eth0: Supported ports: [ MII ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Half 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Half 1000baseT/Full Advertised auto-negotiation: Yes Speed: 100Mb/s Duplex: Full Port: Twisted Pair PHYAD: 1 Transceiver: internal Auto-negotiation: on Supports Wake-on: g Wake-on: d Current message level: 0x000000ff (255) Link detected: yes Verify that your ethernet device is configured with an appropriate IP Address and is UP and RUNNING with the command ifconfig. # ifconfig -a eth0 Link encap:Ethernet HWaddr 00:09:3D:10:51:26 inet addr:10.16.8.63 Bcast:10.16.8.255 Mask:255.255.255.0 inet6 addr: fe80::209:3dff:fe10:5126/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:7 errors:0 dropped:0 overruns:0 frame:0 TX packets:28 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:550 (550.0 b) TX bytes:8535 (8.3 KiB) Interrupt:25 eth1 Link encap:Ethernet HWaddr 00:09:3D:10:51:27 BROADCAST MULTICAST MTU:1500 Metric:1 RX packets:0 errors:0 dropped:0 overruns:0 frame:0 TX packets:0 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:0 (0.0 b) TX bytes:0 (0.0 b) Interrupt:26 lo Link encap:Local Loopback LOOPBACK MTU:16436 Metric:1 RX packets:40 errors:0 dropped:0 overruns:0 frame:0 TX packets:40 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:26787 (26.1 KiB) TX bytes:26787 (26.1 KiB) Configure your ethernet device if necessary. Use dhclient or dhcpcd for dynamic assignment and ifconfig for static assignment. # dhclient eth0 Internet Systems Consortium DHCP Client V3.0.5-RedHat Copyright 2004-2006 Internet Systems Consortium. All rights reserved. For info, please visit http://www.isc.org/sw/dhcp/ Listening on LPF/eth0/00:09:3d:10:51:26 Sending on LPF/eth0/00:09:3d:10:51:26 Sending on Socket/fallback DHCPDISCOVER on eth0 to 255.255.255.255 port 67 interval 3 DHCPDISCOVER on eth0 to 255.255.255.255 port 67 interval 7 DHCPOFFER from 10.16.8.21 DHCPREQUEST on eth0 to 255.255.255.255 port 67 DHCPACK from 10.16.8.21 bound to 10.16.8.63 -- renewal in 2147483648 seconds. # dhcpcd -d eth0 Info, eth0: dhcpcd 3.1.8 starting Info, eth0: hardware address = 00:09:3d:10:51:26 Info, eth0: DUID = 00:01:00:01:0e:fc:d3:16:00:09:3d:10:51:26 Info, eth0: broadcasting for a lease Info, eth0: offered 10.16.8.63 from 10.16.8.21 Info, eth0: checking 10.16.8.63 is available on attached networks Info, eth0: leased 10.16.8.63 for 14400 seconds Info, eth0: no renewal time supplied, assuming 7200 seconds Info, eth0: no rebind time supplied, assuming 12600 seconds Info, eth0: adding IP address 10.16.8.63/24 Info, eth0: adding default route via 10.16.8.1 metric 0 Info, eth0: adding route to 169.254.0.0/16 metric 0 Debug, eth0: forking to background # ifconfig eth0 10.16.8.62 netmask 255.255.255.0 up Verify that other hosts are reachable with the command ping. # ping -c 1 10.16.8.21 PING 10.16.8.21 (10.16.8.21) 56(84) bytes of data. --- 10.16.8.21 ping statistics --- 1 packets transmitted, 0 received, 100% packet loss, time 0ms # ping -c 1 10.16.8.21 PING 10.16.8.21 (10.16.8.21) 56(84) bytes of data. 64 bytes from 10.16.8.21: icmp_seq=1 ttl=255 time=1.83 ms --- 10.16.8.21 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 1.834/1.834/1.834/0.000 ms Ping the the system from a other host and watch the IP traffic on the X64 system with tcpdump. A successful ping has a request and a reply. Use a filter for the host (ip host ), otherwise tcpdump will flood the console. # tcpdump -i eth0 -n ip host 10.16.8.63 tccpdump: verbose output suppressed, use -v or -vv for full protocol decode listening on eth0, link-type EN10MB (Ethernet), capture size 96 bytes 16:34:53.133085 IP 10.16.8.21 > 10.16.8.63: ICMP echo request, id 13641, seq 0, length 64 16:34:53.133250 IP 10.16.8.63 > 10.16.8.21: ICMP echo reply, id 13641, seq 0, length 64 Verify the routing table when only a request is recognized. # netstat -rn Kernel IP routing table Destination Gateway Genmask Flags MSS Window irtt Iface 10.16.8.0 0.0.0.0 255.255.255.0 U 0 0 0 eth0 0.0.0.0 10.16.8.1 0.0.0.0 UG 0 0 0 eth0 Set the default gateway if necessary. # route add default gw 10.16.8.1 Ping your default gateway on the X64 System. # ping -c 1 10.16.8.1 PING 10.16.8.1 (10.16.8.1) 56(84) bytes of data. 64 bytes from 10.16.8.1: icmp_seq=1 ttl=255 time=0.473 ms --- 10.16.8.1 ping statistics --- 1 packets transmitted, 1 received, 0% packet loss, time 0ms rtt min/avg/max/mdev = 0.473/0.473/0.473/0.000 ms At this point, if you followed each troubleshooting step above you have collected the needed information for further troubleshooting. For additional support contact Sun Support. Checking your network on Windows systemsBasic tools for troubleshooting TCP/IP connectivity are available in windows. The commands ipconfig, arp, tracert, netstat and ping are part of most windows operating systems. Configuration can be done with a graphical interface. Most settings are found in the Network Connections folder. Some windows operating systems have a graphical tool for automated troubleshooting. The Network Diagnostics interface can be started directly by using the following command: netsh diag gui. Refer to http://support.microsoft.com/kb/314067/en-us "How to troubleshoot TCP/IP connectivity with Windows XP" and http://support.microsoft.com/kb/323388/en-us "How To Diagnose and Test TCP/IP or NetBIOS Network Connections in Windows Server 2003". Device mapping and examples for Sun X64 servers and workstations
Chassis labeling: ______ ______ | | | | net2 | net3 | |______|______| | | | | net0 | net1 | |______|______| Led description: Led: activity - link - activity - link ______ ______ x x|x x | 2 | 3 | |______|______| | | | | 0 | 1 | x_____x|x_____x Led: activity - link - activity - link link: green = link etstablished at 1 gigabit, amber = link etstablished at 10 or 100 megabits x4100 / x4200 Ethernet port device and driver naming:
/usr/sbin/lspci ... 01:01.0 Ethernet controller: Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) (rev 03) 01:01.1 Ethernet controller: Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) (rev 03) 01:02.0 Ethernet controller: Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) (rev 03) 01:02.1 Ethernet controller: Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) (rev 03) ... /usr/X11/bin/scanpci ... pci bus 0x0001 cardnum 0x01 function 0x00: vendor 0x8086 device 0x1010 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) . pci bus 0x0001 cardnum 0x01 function 0x01: vendor 0x8086 device 0x1010 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) . pci bus 0x0001 cardnum 0x02 function 0x00: vendor 0x8086 device 0x1010 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) . pci bus 0x0001 cardnum 0x02 function 0x01: vendor 0x8086 device 0x1010 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) ethtool -i eth0 driver: e1000 version: 7.2.9-k4 firmware-version: N/A bus-info: 0000:01:01.0
Chassis labeling: ______ ______ | | | | net2 | net3 | |______|______| | | | | net0 | net1 | |______|______| Led description: Led: activity - link - activity - link ______ ______ x x|x x | 2 | 3 | |______|______| | | | | 0 | 1 | x_____x|x_____x Led: activity - link - activity - link link: green = link etstablished at 1 gigabit, amber = link etstablished at 10 or 100 megabits x4100 M2 / x4200 M2 Ethernet port device and driver naming:
/usr/X11/bin/scanpci ... pci bus 0x0000 cardnum 0x0a function 0x00: vendor 0x10de device 0x0057 nVidia Corporation CK804 Ethernet Controller ... pci bus 0x0080 cardnum 0x0a function 0x00: vendor 0x10de device 0x0057 nVidia Corporation CK804 Ethernet Controller ... pci bus 0x0086 cardnum 0x01 function 0x00: vendor 0x8086 device 0x1010 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) . pci bus 0x0086 cardnum 0x01 function 0x01: vendor 0x8086 device 0x1010 Intel Corporation 82546EB Gigabit Ethernet Controller (Copper) ... grep nge /var/adm/messages.1 Jan 5 08:39:53 va64-x4100m-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci10de,57 (nge) instance 0 vector 0x16 ioapic 0xf intin 0x16 is bound to cpu 2 Jan 5 08:39:54 va64-x4100m-gmp03 mac: [ID 469746 kern.info] NOTICE: nge0 registered Jan 5 08:39:54 va64-x4100m-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link down (initialised) Jan 5 08:39:56 va64-x4100m-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link up 100Mbps Full-Duplex (initialised) va64-x4100g-gmp03:~ # ethtool -i eth0 driver: e1000 version: 7.0.33-NAPI firmware-version: N/A bus-info: 0000:86:01.0 va64-x4100g-gmp03:~ # ethtool -i eth1 driver: e1000 version: 7.0.33-NAPI firmware-version: N/A bus-info: 0000:86:01.1 va64-x4100g-gmp03:~ # ethtool -i eth2 driver: forcedeth version: 0.49 firmware-version: bus-info: 0000:00:0a.0 va64-x4100g-gmp03:~ # ethtool -i eth3 driver: forcedeth version: 0.49 firmware-version: bus-info: 0000:80:0a.0 dmesg | grep forcedeth forcedeth.c: Reverse Engineered nForce ethernet driver. Version 0.49. eth2: forcedeth.c: subsystem: 010de:cb84 bound to 0000:00:0a.0 eth3: forcedeth.c: subsystem: 010de:cb84 bound to 0000:80:0a.0 ethtool eth2 Settings for eth2: Supported ports: [ MII ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Advertised auto-negotiation: Yes Speed: 100Mb/s Duplex: Full Port: MII PHYAD: 1 Transceiver: external Auto-negotiation: on Supports Wake-on: g Wake-on: d Link detected: yes
Chassis labeling: ______ ______ | | | | net2 | net3 | |______|______| | | | | net0 | net1 | |______|______| Led description: Led: activity - link - activity - link ______ ______ x x|x x | 2 | 3 | |______|______| | | | | 0 | 1 | x_____x|x_____x Led: activity - link - activity - link link: green = link etstablished at 1 gigabit, amber = link etstablished at 10 or 100 megabits x4600 Ethernet port device and driver naming:
Chassis labeling: ______ ______ | | | | net2 | net3 | |______|______| | | | | net0 | net1 | |______|______| Led description: Led: activity - link - activity - link ______ ______ x x|x x | 2 | 3 | |______|______| | | | | 0 | 1 | x_____x|x_____x Led: activity - link - activity - link link: green = link etstablished at 1 gigabit, amber = link etstablished at 10 or 100 megabits x4600 M2 Ethernet port device and driver naming:
Chassis labeling and Led description Led: activity - link - activity - link +-------+ +-------+ | | | | | 1 | | 2 | |_______| |_______| link: green = link etstablished at 1 gigabit, amber = link etstablished at 10 or 100 megabits x2100 Ethernet port device and driver naming:
/usr/X11/bin/scanpci ... pci bus 0x0000 cardnum 0x0a function 0x00: vendor 0x10de device 0x0057 nVidia Corporation CK804 Ethernet Controller ... pci bus 0x0004 cardnum 0x00 function 0x00: vendor 0x14e4 device 0x1659 Broadcom Corporation NetXtreme BCM5721 Gigabit Ethernet PCI Express bash-3.00# grep -i bge /var/adm/messages Dec 13 09:52:51 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci14e4,1659 (bge) instance 0 vector 0x13 ioapic 0x2 intin 0x13 is bound to cpu 0 Dec 13 09:52:51 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: bge0/0 registered Dec 13 09:54:27 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci14e4,1659 (bge) instance 0 vector 0x13 ioapic 0x2 intin 0x13 is bound to cpu 1 Dec 13 09:54:27 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: bge0/0 registered Dec 13 10:02:16 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci14e4,1659 (bge) instance 0 vector 0x13 ioapic 0x2 intin 0x13 is bound to cpu 1 Dec 13 10:02:16 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: bge0/0 registered Dec 13 10:02:24 va64-x2100a-gmp03 mac: [ID 846399 kern.info] NOTICE: bge0/0 unregistered Dec 13 11:00:43 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci14e4,1659 (bge) instance 0 vector 0x13 ioapic 0x2 intin 0x13 is bound to cpu 1 Dec 13 11:00:44 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: bge0/0 registered Dec 13 11:00:51 va64-x2100a-gmp03 mac: [ID 846399 kern.info] NOTICE: bge0/0 unregistered bash-3.00# grep -i nge /var/adm/messages Dec 13 09:54:18 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci10de,57 (nge) instance 0 vector 0x14 ioapic 0x2 intin 0x14 is bound to cpu 0 Dec 13 09:54:18 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: nge0/0 registered Dec 13 09:54:19 va64-x2100a-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link down (initialised) Dec 13 09:54:20 va64-x2100a-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link up 100Mbps Full-Duplex (initialised) Dec 13 10:01:53 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci10de,57 (nge) instance 0 vector 0x14 ioapic 0x2 intin 0x14 is bound to cpu 0 Dec 13 10:01:53 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: nge0/0 registered Dec 13 10:01:54 va64-x2100a-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link down (initialised) Dec 13 10:01:55 va64-x2100a-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link up 100Mbps Full-Duplex (initialised) Dec 13 11:00:22 va64-x2100a-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci10de,57 (nge) instance 0 vector 0x14 ioapic 0x2 intin 0x14 is bound to cpu 0 Dec 13 11:00:22 va64-x2100a-gmp03 mac: [ID 543131 kern.info] NOTICE: nge0/0 registered Dec 13 11:00:23 va64-x2100a-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link down (initialised) Dec 13 11:00:24 va64-x2100a-gmp03 nge: [ID 223987 kern.info] NOTICE: nge0: link up 100Mbps Full-Duplex (initialised) bash-3.00#
Chassis labeling: +-------+ +-------+ +-------+ | | | | | | | 0 | | 2 | | 3 | |_______| |_______| |_______| | | | 1 | | | +-------+
/usr/X11/bin/scanpci ... pci bus 0x0000 cardnum 0x08 function 0x00: vendor 0x10de device 0x0373 nVidia Corporation MCP55 Ethernet . pci bus 0x0000 cardnum 0x09 function 0x00: vendor 0x10de device 0x0373 nVidia Corporation MCP55 Ethernet ... pci bus 0x0006 cardnum 0x04 function 0x00: vendor 0x14e4 device 0x1678 Broadcom Corporation NetXtreme BCM5715 Gigabit Ethernet . pci bus 0x0006 cardnum 0x04 function 0x01: vendor 0x14e4 device 0x1678 Broadcom Corporation NetXtreme BCM5715 Gigabit Ethernet grep bge /var/adm/messages.0 Dec 3 14:02:00 va64-x2100k-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci14e4,1678 (bge) instance 0 vector 0x10 ioapic 0x2 intin 0x10 is bound to cpu 1 Dec 3 14:02:00 va64-x2100k-gmp03 mac: [ID 469746 kern.info] NOTICE: bge0 registered Dec 3 14:02:00 va64-x2100k-gmp03 bge: [ID 801725 kern.info] NOTICE: bge0: link down (initialized) Dec 3 14:02:05 va64-x2100k-gmp03 bge: [ID 801725 kern.info] NOTICE: bge0: link up 1000Mbps Full-Duplex (initialized) Dec 3 14:02:15 va64-x2100k-gmp03 pcplusmp: [ID 398438 kern.info] pcplusmp: pci14e4,1678 (bge) instance #1 vector 0x11 ioapic 0x2 intin 0x11 is bound to cpu 1 Dec 3 14:02:15 va64-x2100k-gmp03 mac: [ID 469746 kern.info] NOTICE: bge1 registered Dec 4 11:00:19 va64-x2100k-gmp03 bge: [ID 801593 kern.notice] NOTICE: bge0: link down Dec 4 11:00:23 va64-x2100k-gmp03 bge: [ID 801593 kern.notice] NOTICE: bge0: link up 1000Mbps Full-Duplex grep nge /var/adm/messages.0 Dec 3 15:17:24 va64-x2100k-gmp03 pcplusmp: [ID 637496 kern.info] pcplusmp: pci10de,373 (nge) instance 0 vector 0x17 ioapic 0x2 intin 0x17 is bound to cpu 0 Dec 3 15:17:24 va64-x2100k-gmp03 mac: [ID 469746 kern.info] NOTICE: nge0 registered Dec 3 15:17:25 va64-x2100k-gmp03 mac: [ID 469746 kern.info] NOTICE: nge1 registered
Chassis labeling: +-------+ | | | 1 | |_______| | | | 0 | | | +-------+
lspci ... 02:02.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5703X Gigabit Ethernet (rev 02) 02:03.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5703X Gigabit Ethernet (rev 02) ... /usr/X11/bin/scanpci ... pci bus 0x0002 cardnum 0x02 function 0x00: vendor 0x14e4 device 0x16a7 Broadcom Corporation NetXtreme BCM5703X Gigabit Ethernet . pci bus 0x0002 cardnum 0x03 function 0x00: vendor 0x14e4 device 0x16a7 Broadcom Corporation NetXtreme BCM5703X Gigabit Ethernet ... ethtool -i eth0 driver: tg3 version: 3.75.1 firmware-version: 5703-v2.35 bus-info: 0000:02:02.0 dmesg | grep -e eth -e tg3 tg3.c:v3.75.1 (May 7, 2007) eth0: Tigon3 [partno(BCM95703A30) rev 1002 PHY(5703)] (PCIX:66MHz:64-bit) 10/100/1000Base-T Ethernet 00:09:3d:10:51:26 eth0: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] WireSpeed[1] TSOcap[1] eth0: dma_rwctrl[769c0000] dma_mask[64-bit] eth1: Tigon3 [partno(BCM95703A30) rev 1002 PHY(5703)] (PCIX:66MHz:64-bit) 10/100/1000Base-T Ethernet 00:09:3d:10:51:27 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] WireSpeed[1] TSOcap[1] eth1: dma_rwctrl[769c0000] dma_mask[64-bit] ADDRCONF(NETDEV_UP): eth0: link is not ready tg3: eth0: Link is up at 100 Mbps, full duplex. tg3: eth0: Flow control is off for TX and off for RX. ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready eth0: no IPv6 routers present ethtool eth0 Settings for eth0: Supported ports: [ MII ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Half 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Half 1000baseT/Full Advertised auto-negotiation: Yes Speed: 100Mb/s Duplex: Full Port: Twisted Pair PHYAD: 1 Transceiver: internal Auto-negotiation: on Supports Wake-on: g Wake-on: d Current message level: 0x000000ff (255) Link detected: yes
The Ultra 20 has only one NIC.
lspci ... 00:0a.0 Bridge: nVidia Corporation CK804 Ethernet Controller (rev a3) ... /usr/X11/bin/scanpci ... pci bus 0x0000 cardnum 0x0a function 0x00: vendor 0x10de device 0x0057 nVidia Corporation CK804 Ethernet Controller ... ethtool -i eth0 driver: forcedeth version: 0.60 firmware-version: bus-info: 0000:00:0a.0 ethtool eth0 Settings for eth0: Supported ports: [ MII ] Supported link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Supports auto-negotiation: Yes Advertised link modes: 10baseT/Half 10baseT/Full 100baseT/Half 100baseT/Full 1000baseT/Full Advertised auto-negotiation: Yes Speed: 1000Mb/s Duplex: Full Port: MII PHYAD: 1 Transceiver: external Auto-negotiation: on Supports Wake-on: g Wake-on: g Link detected: yes dmesg | grep -e eth0 -e forcedeth forcedeth.c: Reverse Engineered nForce ethernet driver. Version 0.60. forcedeth: using HIGHDMA eth0: forcedeth.c: subsystem: 0108e:5347 bound to 0000:00:0a.0 eth0: no IPv6 routers present grep nge /var/adm/messages Dec 17 06:38:47 u20.local pcplusmp: [ID 637496 kern.info] pcplusmp: pci10de,57 (nge) instance 0 vector 0x17 ioapic 0x2 intin 0x17 is bound to cpu 0 Dec 17 06:38:47 u20.local mac: [ID 469746 kern.info] NOTICE: nge0 registered Dec 17 06:38:48 u20.local nge: [ID 223987 kern.info] NOTICE: nge0: link down (initialised) Dec 17 06:38:49 u20.local /sbin/dhcpagent[56]: [ID 116611 daemon.error] interface nge0 has gone down Dec 17 06:38:52 u20.local nge: [ID 223987 kern.info] NOTICE: nge0: link up 1000Mbps Full-Duplex (initialised) Dec 17 06:38:52 u20.local /sbin/dhcpagent[56]: [ID 116611 daemon.error] interface nge0 has come back up grep -e eth0 -e forcedeth /var/log/messages Dec 18 18:59:13 u20 forcedeth.c: Reverse Engineered nForce ethernet driver. Version 0.60. Dec 18 18:59:13 u20 forcedeth: using HIGHDMA Dec 18 18:59:13 u20 eth0: forcedeth.c: subsystem: 0108e:5347 bound to 0000:00:0a.0 Dec 18 18:59:18 u20 dhcpcd[3991]: eth0: dhcpcd 3.1.8 starting Dec 18 18:59:18 u20 dhcpcd[3991]: eth0: hardware address = 00:e0:81:73:1f:bf Dec 18 18:59:18 u20 dhcpcd[3991]: eth0: DUID = 00:01:00:01:0e:3a:a3:08:00:e0:81:59:6d:22 Dec 18 18:59:18 u20 dhcpcd[3991]: eth0: broadcasting for a lease Dec 18 18:59:18 u20 dhcpcd[3991]: eth0: offered 192.168.0.3 from 192.168.0.100 Dec 18 18:59:18 u20 dhcpcd[3991]: eth0: checking 192.168.0.3 is available on attached networks Dec 18 18:59:19 u20 dhcpcd[3991]: eth0: leased 192.168.0.3 for 86400 seconds Dec 18 18:59:19 u20 dhcpcd[3991]: eth0: adding IP address 192.168.0.3/24 Dec 18 18:59:19 u20 dhcpcd[3991]: eth0: adding default route via 192.168.0.100 metric 0 Dec 18 18:59:19 u20 dhcpcd[3991]: eth0: adding route to 169.254.0.0/16 metric 0 Dec 18 18:59:19 u20 dhcpcd[3991]: eth0: setting hostname to `u20.local' Dec 18 18:59:19 u20 dhcpcd[3991]: eth0: exiting Dec 18 18:59:38 u20 eth0: no IPv6 routers present
+-------+ | | | 0 | |_______| | | | 1 | | | +-------+
+-------+ | | | 1 | |_______| | | | 0 | | | +-------+
grep nge /var/adm/messages Dec 17 14:34:05 netrep-u40a-gmp03 nge: [ID 801725 kern.info] NOTICE: nge0: Using FIXED interrupt type Dec 17 14:34:05 netrep-u40a-gmp03 pcplusmp: [ID 803547 kern.info] pcplusmp: pci10de,57 (nge) instance 0 vector 0x17 ioapic 0x4 intin 0x17 is bound to cpu 0 Dec 17 14:34:05 netrep-u40a-gmp03 mac: [ID 469746 kern.info] NOTICE: nge0 registered Dec 17 14:34:07 netrep-u40a-gmp03 mac: [ID 435574 kern.info] NOTICE: nge0 link up, 100 Mbps, full duplex Dec 17 14:34:09 netrep-u40a-gmp03 nge: [ID 801725 kern.info] NOTICE: nge1: Using FIXED interrupt type Dec 17 14:34:09 netrep-u40a-gmp03 pcplusmp: [ID 444295 kern.info] pcplusmp: pci10de,57 (nge) instance #1 vector 0x2e ioapic 0x5 intin 0x16 is bound to cpu 0 Dec 17 14:34:09 netrep-u40a-gmp03 mac: [ID 469746 kern.info] NOTICE: nge1 registered Dec 17 14:34:56 netrep-u40a-gmp03 mac: [ID 736570 kern.info] NOTICE: nge1 unregistered /usr/X11/bin/scanpci ... pci bus 0x0000 cardnum 0x0a function 0x00: vendor 0x10de device 0x0057 nVidia Corporation CK804 Ethernet Controller ... pci bus 0x0080 cardnum 0x0a function 0x00: vendor 0x10de device 0x0057 nVidia Corporation CK804 Ethernet Controller Previously Published As 91541 Attachments This solution has no attachment |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|