Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1005177.1
Update Date:2017-06-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1005177.1 :   Sun StorEdge T3 Arrays: Troubleshooting controller failure  


Related Items
  • Sun Storage T3 Array
  •  
  • Sun Storage T3 Array for the Enterprise (T3ES)
  •  
  • Sun Storage T3+ Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: T3_6020_6120
  •  

PreviouslyPublishedAs
207265


Applies to:

Sun Storage T3 Array - Version Not Applicable and later
Sun Storage T3+ Array - Version Not Applicable and later
Sun Storage T3 Array for the Enterprise (T3ES) - Version All Versions to All Versions [Release All Releases]
All Platforms

Goal

In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment.

These symptoms will hyperlink you into a relevant content that will

  1) Tell you how to validate the listed symptom and

  2) How to fix the symptom if it is true for your environment.

 

Solution

The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix.

Please do not skip a step.

 

Symptoms:

   Controller offline

   Disabled controller

   Offlined paths

   Can't see device



Steps to Follow

 

Sun StorEdge T3 controller failure

 

NOTE: This  is a sub-set of <Document: 1018272.1> "Troubleshooting Sun StorEdge[TM] T3 Hardware"  This document will help with disabled controllers based on similar "fru stat" output below:

storage-t3b:/:<7>fru stat

CTLR    STATUS   STATE       ROLE        PARTNER    TEMP
------  -------  ----------  ----------  -------    ----
u1ctr   ready    enabled     master      -          31
u2ctr   ready    disabled     -          -          29

 

Troubleshooting Steps:

NOTE: There are two scenarios based on which controller has failed. Choose the appropriate option based on your "fru stat".

 

Controller u1ctr disabled

1. Enable the controller  with "enable u<encid>" command.

 

Example:

storage-t3b:/:<3>enable u1

 

NOTE:  Wait about 5 minute before running "fru stat" as to allow the array to boot the disabled controller.

 

2. If the u1 controller  is still not ready enabled, then  replace controller, otherwise proceed step 3.

 

NOTE: Do not proceed to step 3 unless U1 and U2 are enabled.

 

3. disable u2      <---this will allow for U1 to be the master controller (preferred config)

 

4. enable u2

 

NOTE:  Wait about 5 minute before running "fru stat" as to allow the array to boot the disabled controller.

 

NOTE: Now "fru stat" should show the master as u1 and the alternate as u2

CTLR    STATUS   STATE       ROLE        PARTNER    TEMP
------  -------  ----------  ----------  -------    ----
u1ctr   ready    enabled     master      u2ctr      31
u2ctr   ready    enabled     alt master  u1ctr      29

 

Controller u2ctr disabled

 

1.  Enable the controller  with "enable u<encid>" command.

 

Example:

storage-t3b:/:<3>enable u2

 

2.  Verify that the controller is now ready and enabled with the "fru stat" command.

NOTE:  Wait about 5 minute before running "fru stat" as to allow the array to boot the disabled controller.

 

3.  If the controller  is still not ready enabled, then  replace controller.



Product
Sun StorageTek T3 Array
Sun StorageTek T3+ Array


Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains.

 

 

Place Sun Internal-Use Only content here.

T3, T3+, disabled controller, audited
Previously Published As
86656

 

Change History
Date: 2006-08-18
User Name: 7058
Action: Approved
Comment: Reformatted doc.
Re-indexed links.
Spell ck OK.
OK to publish.
Version: 3

 

Date: 2006-08-17
User Name: 123825
Action: Approved
Comment: t3 norm
Version: 0
Date: 2006-08-17
User Name: 78962
Action: Approved
Comment: T3 norm
Version: 0
Date: 2006-08-15
User Name: 78962
Action: Created
Comment:
Version: 0


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback