Solution Type Technical Instruction Sure Solution 1004374.1 : SL8500 - Information on the Self Test Using SL Console
PreviouslyPublishedAs 206050 Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms GoalDescription The SL8500 Self Test Diagnostic Routines were introduced at FRS_1.10 (3.20). The SL8500 Full SelfTest diagnostic routine is available with all current microcode releases. SolutionPurpose:
The SLC SelfTest diagnostic is intended to be run as a minimal functional test at initial install and at periodic intervals after the initial installation; to diagnose basic problems with library operation (e.g. robots, elevator, drives, CAP). The test is currently accessed through the "Utility" menu of the StreamLine Library Console (SLC). Two options are available, Partial and Full. The partial option tests are non-disruptive to customer operations. The "full" option is a complete suite of tests that are disruptive and is primarily intended as a "checkout" after the initial installation. The SelfTest Diagnostic Routines test the communication paths between the main library controller (HBC) and all drives, Sbots, elevators and caps. After checking the communication paths, several motion tests are performed ? including Sbot, elevator and CAP motion tests. Finally, a full audit of the SL8500 is performed, followed by drive mounts and dismounts. Success or failure of the tests is recorded in a scrollable window on the StreamLine Library Console (SLC) and in the SL8500 event log. Requirements: -8 diagnostic tapes with external volsers with a prefix of DG (i.e. DG0001L2). -2 diagnostic tapes per rail, one on each end of the rail. -The diagnostic tapes must be placed in the Playground area. The Playground area is the last two columns in the CIM on both sides of the library. -The Full Self Test requires the Library to be in an Offline Operation State in SLC. This is accomplished through the SLC system detail screen. Note: To date there is no asynchronous notification sent from the library controller to the library manager, i.e. HSC and ACSLS, indicating the library was taken offline. If the customer is in production, first vary the library offline to the library manager before varying the library offline via SLC. Test Run Times: Partial SelfTest takes approximately 5 minutes. Full SelfTest is configuration dependent but will take approximately 22 minutes in a standard SL8500 (no CEM) with 6 available drives. SLC SelfTest Help Information: Performing the Library Self Test There are two types of library self test: * Partial Partial Self Test Full Self Test Warning: The library has to be takes offline to perform a full self-test. So, make sure to end all the library operations that are currently active before performing a full self test. To Perform a Library Self Test: 1. Select Tools > Utilities. 4. To perform a full self test, do the following: After completing the self test the system displays a summary report of the diagnostic tests performed. 5. If you performed a full self test, you must change the operational state of the library to Online. Follow steps 4a through 4c. In step 4d select Online from the pull-down menu and then select Apply. Self Test-Partial Diagnostic Routines: Diagnostic started Power supply test Success OK: No tests available yet Cooling fan test Success OK: No tests available yet Network connectivity test Success OK: 1,0,0,0,0 library Network connectivity test Success OK: 1,1,0,1,0 robot Network connectivity test Success OK: 1,2,0,1,0 robot Network connectivity test Success OK: 1,3,0,1,0 robot Network connectivity test Success OK: 1,4,0,1,0 robot Network connectivity test Success OK: 1,2,15,2,0 cap Network connectivity test Success OK: 1,0,-14,2,0 elevator Network connectivity test Success OK: 1,0,14,2,0 elevator Network connectivity test Success OK: 1,0,0,1,0 driveController Device internal status test Success OK: No tests available yet Drive health test Success OK: 1,1,2,1,4 drive Drive health test Success OK: 1,2,-2,1,4 drive Drive health test Success OK: 1,2,2,1,4 drive Drive health test Success OK: 1,3,2,1,4 drive Drive health test Success OK: 1,4,-2,1,1 drive Drive health test Success OK: 1,4,2,1,4 drive Temperature sensor test Success OK: No tests available yet Robot motion test Success OK: 1,1,0,1,0 robot Robot motion test Success OK: 1,2,0,1,0 robot Robot motion test Success OK: 1,3,0,1,0 robot Robot motion test Success OK: 1,4,0,1,0 robot Elevator motion test Success OK: 1,0,-14,2,0 elevator Elevator motion test Success OK: 1,0,14,2,0 elevator Safety door motion test Success OK: No tests available yet Ptp motion test Success OK: No tests available yet Turntable motion test Success OK: No tests available yet Host configuration test Success OK: No tests available yet Final test conclusion Success OK Diagnostic completed Self Test-Full Diagnostic Routines: Diagnostic started Power supply test Success OK: No tests available yet Cooling fan test Success OK: No tests available yet Network connectivity test Success OK: 1,0,0,0,0 library Network connectivity test Success OK: 1,1,0,1,0 robot Network connectivity test Success OK: 1,2,0,1,0 robot Network connectivity test Success OK: 1,3,0,1,0 robot Network connectivity test Success OK: 1,4,0,1,0 robot Network connectivity test Success OK: 1,2,15,2,0 cap Network connectivity test Success OK: 1,0,-14,2,0 elevator Network connectivity test Success OK: 1,0,14,2,0 elevator Network connectivity test Success OK: 1,0,0,1,0 drive Controller Device internal status test Success OK: No tests available yet Drive health test Success OK: 1,1,2,1,4 drive Drive health test Success OK: 1,2,-2,1,4 drive Drive health test Success OK: 1,2,2,1,4 drive Drive health test Success OK: 1,3,2,1,4 drive Drive health test Success OK: 1,4,-2,1,1 drive Drive health test Success OK: 1,4,2,1,4 drive Temperature sensor test Success OK: No tests available yet Robot motion test Success OK: 1,1,0,1,0 robot Robot motion test Success OK: 1,2,0,1,0 robot Robot motion test Success OK: 1,3,0,1,0 robot Robot motion test Success OK: 1,4,0,1,0 robot Elevator motion test Success OK: 1,0,-14,2,0 elevator Elevator motion test Success OK: 1,0,14,2,0 elevator Safety door motion test Success OK: No tests available yet Cap motion test Success OK: 1,2,15,2,0 cap Ptp motion test Success OK: No tests available yet Turntable motion test Success OK: No tests available yet Audit test Success OK: Audits completed successfully Drive mount/dismount test Success OK: 1,1,2,1,4 drive Drive mount/dismount test Success OK: 1,2,-2,1,4 drive Drive mount/dismount test Success OK: 1,2,2,1,4 drive Drive mount/dismount test Success OK: 1,3,2,1,4 drive Drive mount/dismount test Success OK: 1,4,-2,1,1 drive Drive mount/dismount test Success OK: 1,4,2,1,4 drive Host configuration test Success OK: No tests available yet Final test conclusion Success OK Diagnostic completed
Attachments This solution has no attachment |
||||||||||||
|