Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1003993.1
Update Date:2018-04-11
Keywords:

Solution Type  Technical Instruction Sure

Solution  1003993.1 :   Sun SPARC Enterprise[TM] M3000/M4000/M5000/M8000/M9000: Field Replaceable Unit (FRU) and Customer Replaceable Unit (CRU) Replacement Methods  


Related Items
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  

PreviouslyPublishedAs
205574


Applies to:

Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-64 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun SPARC Enterprise M9000-32 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
All Platforms

Goal

This document describes the three replacement methods and provides information on which FRUs and CRUs can be replaced using which method(s).  This document should be used to decide which method is best to utilize given the system configuration and the FRU which requires service.

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - M Series Servers

Solution

Description
Field Replaceable Units (FRUs) and Customer Replaceable Units (CRUs) can be replaced on Sun SPARC Enterprise[TM] M3000/M4000/M5000/M8000/M9000 systems using one of three possible replacement methods:

  • Cold Replacement

  • Hot Replacement

  • Active Replacement

This document is Step 5 of  Document 1002526.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000: Field Replaceable Unit (FRU) Service Action Plan Reference.

Regarding Hard Disk Drive (HDD) Replacement Methods
If the HDD is the boot device, it will have to be replaced using cold replacement procedures. However, active replacement can be used if the boot disk can be isolated from the Oracle Solaris OS by disk mirroring software and other software.


Steps to Follow
Cold Replacement Method requires all domains and the entire platform be shut down and powered off in order to replace the FRU/CRU. Every FRU/CRU in Mx000 platforms can be Cold Replaced, but some must be replaced using this method.

Cold Replacement Method

The components which must be Cold Replaced on M3000 are:

MBU_A           MBU_A_2        DIMM       PCIe       HDDBP

PSU             DVDU           FAN_A      FANBP_B    OPNL

The components which must be Cold Replaced on M4000/M5000 are:

MBU_A           MBU_B          CPUM       MEMB       DIMM

DDC_A           DDC_B          XSCFU      IOU        DDCR

FANBP_A         FANBP_B        FANBP_C    BPU_A      BPU_B

HDDBP           TAPEBP         DVD        DVDBP_A    DVDBP_B

OPNL

The components which must be Cold Replaced on M8000/M9000 are:

XBU_B           CLKU_B         OPNL       SNSU       ACS_A

ACS_B           ACS_C          ACS_D      ACSTPH_A   ACSTPH_B

ACSTPH-C        ACSTPH-D       BP_A       BP_B       PSUBP_A

PSUBP_B         FANBP_A        FANBP_B    FANBP_C    MEDBP

SWBP            RDPF

 

The following steps are simply a reference to make one aware of what is involved in the Cold Replacement Method process, but the Service Manual is the authoritative resource for the actual process to be followed.

  • Shut down all applications (if running) on all domains on platform.

  • Shut down all domains.

  • Power off the platform.

  • Unplug the power cords (Make sure to be at the same potential as the system).

  • Initiate FRU replacement.

  • Power on the platform and verify FRU replacement is successful.

  • Bring domains and applications back online.

Hot Replacement Method

Hot Replacement Method requires that the domain(s) containing the faulty FRU/CRU be shut down in order to replace it. The remainder of the platform can stay in operation during the service period. Fans and PSUs are not part of domains and can therefore be replaced while all domains are running. Special rules apply for these FRUs to guarantee redundancy during the replacement operation, they are described later in this document.

The components which can be Hot Replaced on M3000 are:

FAN_A           HDD          PSU

The components which can be Hot Replaced on M4000/M5000 are:

HDD

The components which can be Hot Replaced on M8000/M9000 are:


CMU             CPUM_A         CPUM_B     DIMM         IOU

PCICS           IOUA           PCIB-EX    XSCFU_B      XSCFU_C

PSU             FAN_A          FAN_B      DDC_A

DVDU            TAPEU

The following steps are simply a reference to make one aware of what is involved in the Hot Replacement Method process, but the Service Manual is the authoritative resource for the actual process to be followed.

  • Shut down applications (if running) on domains that contain the FRU.

  • Shut down domains that contain the FRU.

  • Initiate FRU/CRU replacement.

  • Verify FRU/CRU replacement is successful.

  • Bring affected domains and applications back online.

Active Replacement Method

Active Replacement Method can only be used on redundantly configured FRUs/CRUs that can be Dynamically Reconfigured (DR) into or out of a domain.  No interruption to domain or platform operations will occur when utilizing this method. Fans and PSUs are not part of domains and can therefore be replaced while all domains are running

 

NOTE:  Active Replacement was not available until XCP 1050.

 

 

The components which can be Active Replaced on M3000 are:

HDD             PSU            FAN_A

The components which can be Active Replaced on M4000/M5000 are:

PCICS           PSU            PCIB-EX    HDD          TAPE

The components which can be Active Replaced on M8000/M9000 are:

CMU             CPUM_A         CPUM_B     DIMM         IOU

HDD             PCICS          IOUA       PCIB-EX      XSCFU_B

XSCFU_C         DVDU           TAPEU      PSU          FAN_A

FAN_B           DDC_A

The following steps are simply a reference to make one aware of what is involved in the Active Replacement Method process, but the Service Manual is the authoritative resource for the actual process to be followed.

  • Verify the FRU is redundantly configured in all domains in which this FRU is configured.

  • Verify the FRU and all dependent hardware on the FRU (I/O adapters, etc) are inactive.

  • Verify that resources are switched to alternate paths (I/O, network, etc) if necessary.  This may include breaking disk mirrors or utilizing multi-pathing software to perform the actions.

  • Initiate FRU/CRU replacement utilizing Dynamic Reconfiguration.

  • Verify FRU/CRU replacement is successful.

  • Verify that any inactivated paths are re-enabled for all affected domains.  This may include syncing disk mirrors or utilizing multi-pathing software to perform the actions.

  • Verify that the affected domains and applications are all still online without issues.

FRU List Tables

Sun SPARC Enterprise M3000

Component Description Cold Replacement Hot Replacement Active Replacement

FRU/CRU

And Action Plan

MBU_A Motherboard Unit (M3000) Yes No No

FRU

CAP 1293770.1

Dimm Main Memory DIMM Yes No No

 FRU

                                                                   

CAP 1290218.1

PCIe PCIe Card Yes No No

FRU

CAP 1290151.1

HDD Hard Disk Drive Yes Yes Yes if Mirrored

CRU

AP 1290205.1

HDDBP Hard disk drive backplane Yes No No

FRU

CAP 1290180.1

DVDU CD-RW/DVD-RW drive unit Yes No No

 FRU

CAP 1292446.1

PSU Power Supply Unit Yes Yes Yes

 CRU

AP 1315095.1

FAN_A Fan Yes Yes Yes

 FRU

CAP 1290538.1

FANBP_B Fan backplane Yes No No

 FRU

 

OPNL Operator Panel Yes No No

 FRU

CAP 1290220.1

 

Sun SPARC Enterprise M4000/M5000

Component

Description

Cold Replacement

Hot Replacement

Active Replacement

FRU/CRU

MBU_A

Motherboard Unit (M4000)

Yes

No

No

FRU

CAP 1310975.1

MBU_B

Motherboard Unit (M5000)

Yes

No

No

FRU

CAP 1310968.1

DDC_A

DC-DC Converter (Motherboard and IO Unit)

Yes

No

No

FRU

CAP 1291514.1

DDC_B

DC-DC Converter with metal heatsink (Motherboard and IO Unit)

Yes

No

No

FRU

CAP 1291514.1

CPUM

CPU Module Unit

Yes

No

No

FRU

CAP 1310852.1

MEMB

Memory Board

Yes

No

No

FRU

CAP 1310994.1

DIMM

Main Memory DIMM (1, 2, or 4GB)

Yes

No

No

FRU

CAP 1310901.1

XSCFU

eXtended System Control Facility Unit

Yes

No

No

FRU

CAP 1310979.1

IOU

I/O Unit

Yes

No

No

FRU

CAP 1310950.1

DDCR

I/O DC Riser

Yes

No

No

FRU

PCICS

PCI Cassette (including PCI card)

Yes

Yes

Yes

FRU

CAP 1310986.1

PCIB-EX

I/O Box Down Link Card

Yes

Yes

Yes

FRU

Copper CAP 1310920.1

Fibre CAP 1310912.1

FAN_A

172mm Fans

Yes

No

Yes, One unit at a time to support redundancy

FRU

CAP 1290538.1

FAN_B

60mm Fan (M4000)

Yes

No

Yes, One unit at a time to support redundancy

FRU

CAP 1290538.1

 

FANBP_A

172mm Fan Backplane (M4000)

Yes

No

No

FRU

CAP 1310821.1

 

FANBP_B

60mm Fan Backplane (M4000)

Yes

No

No

FRU

CAP 1310831.1

 

FANBP_C

172mm Fan Backplane (M5000)

Yes

No

No

FRU

CAP 1310823.1

PSU

Power Supply Unit

Yes

No

Yes, One unit at a time to support redundancy

CRU

                                                            

AP 1315095.1

BPU_A

I/O Backplane / Power Backplane (M4000)

Yes

No

No

 FRU

CAP 1310839.1

BPU_B

Bus Bar / I/O Backplane / Power Backplane (M5000)

Yes

No

No

FRU

CAP 1310825.1

HDD

73GB Hard Disk Drive

Yes

Yes

Yes, if mirrored

CRU

AP 1310916.1

HDDBP

Hard Disk Drive backplane

Yes

No

No

FRU

M4000 CAP 1310846.1

M5000 CAP

TAPE

DAT Tape Drive (Optional)

Yes

No

Yes

FRU

CAP 1310926.1

TAPEBP

DAT Tape Drive Backplane

Yes

No

No

FRU

M4000 CAP

M5000 CAP 1310811.1

 

DVD

DVD Drive

Yes

No

No

FRU

CAP 1310944.1

 

DVDBP_A

DVD Drive Backplane (M4000)

Yes

No

No

FRU

CAP 1310833.1

DVDBP_B

DVD Drive Backplane (M5000)

Yes

No

No

 FRU

CAP 1310833.1

OPNL

Operator Panel

Yes

No

No

FRU

CAP 1310934.1

The information in the table above comes from the Sun  SPARC  Enterprise M4000/M5000 Servers Service Manual, Appendix C.

Sun SPARC Enterprise M8000/M9000 FRU Replacement Options

FRU

Description

Cold Replacement

Hot Replacement

Active Replacement

CMU

CPU Memory Board Unit

Yes

Yes

Yes

CPUM_A

CPU Module

Yes

Yes

Yes

CPUM_B

CPU Module

Yes

Yes

Yes

DIMM

Main Memory DIMM

Yes

Yes

Yes

IOU

I/O Unit

Yes

Yes

Yes, when redundantly configured. (Uses DR)

HDD

Hard Disk Drive

Yes

No

Yes, if mirrored

PCICS

PCI Cassette (including PCI board)

Yes

Yes

Yes, when multi path is configured.

IOUA

On board Device Card

Yes

Yes

Yes, if boot disks are mirrorred and multipathed

PCIB-EX

I/O Box Down Link Card

Yes

Yes

Yes

XBU_B

Crossbar Units

Yes

No

No

CLKU_B

Clock Control Units

Yes

No

No

XSCFU_B

XSCF Units (Base  Cabinet)

Yes

Yes

Yes

XSCFU_C

XSCF Unit (M9000 Expansion Cabinet)

Yes

Yes

Yes

DVDU

DVD Drive Unit

Yes

Yes

Yes

TAPEU

Tape Drive Unit

Yes

Yes

Yes

OPNL

Operator Panel

Yes

No

No

SNSU

Sensor Unit

Yes

No

No

PSU

Power Supply Unit

Yes

Yes, One unit at a time to support redundancy

Yes, One unit at a time to support redundancy

ACS_A

AC Section Single Phase (M8000)

Yes

No

No

ACS_B

AC Section Single Phase  (M9000) and  Optional Dual Power Feed Power Cabinet

Yes

No

No

ACS_C

AC Section  Single Phase Dual Power Feed Option  (M8000)

Yes

No

No

ACS_D

AC Section (3-Phase Dual Power Feed)

Yes

No

No

ACSTPH_A

M8000 3-Phase Delta Dual feed

Yes

No

No

ACSTPH_B

M8000 3-Phase Star Dual feed

Yes

No

No

ACSTPH_C

M9000 3-Phase Delta Dual feed

Yes

No

No

ACSTPH_D

M9000 3-Phase Star Dual feed

Yes

No

No

FAN_A

3 Fan Unit

Yes

Yes, One unit at a time to support redundancy

Yes, One unit at a time to support redundancy

FAN_B

2 Fan Unit

Yes

Yes, One unit at a time to support redundancy

Yes, One unit at a time to support redundancy

BP_A

Backplane (M8000)

Yes

No

No

DDC_A

DC-DC Converter (only found in M8000)

Yes

Yes

Yes

BP_B

Backplane (M9000)

Yes

No

No

PSUBP_A

PSU Backplane (M9000)

Yes

No

No

PSUBP_B

PSU Backplane (M8000)

Yes

No

No

FANBP_A

Fan Backplane (M9000)

Yes

No

No

FANBP_B

Fan Backplane (M9000)

Yes

No

No

FANBP_C

Fan Backplane (M8000)

Yes

No

No

MEDBP

Media Backplane

Yes

No

No

SWBP

Switch Backplane

Yes

No

No

RDPF

Rack Mountable Dual Feed Option (M8000)

Yes

No

No




See Bug 15604747 for details on why the M4000/M5000 systems do not use hot replacement methods for FAN and PSU
Previously Published As 87405


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback