Asset ID: |
1-71-1003993.1 |
Update Date: | 2018-04-11 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1003993.1
:
Sun SPARC Enterprise[TM] M3000/M4000/M5000/M8000/M9000: Field Replaceable Unit (FRU) and Customer Replaceable Unit (CRU) Replacement Methods
Related Items |
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M9000-64 Server
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M4000 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
- _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
|
PreviouslyPublishedAs
205574
Applies to:
Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-64 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun SPARC Enterprise M9000-32 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
All Platforms
Goal
This document describes the three replacement methods and provides information on which FRUs and CRUs can be replaced using which method(s). This document should be used to decide which method is best to utilize given the system configuration and the FRU which requires service.
Solution
Description
Field Replaceable Units (FRUs) and Customer Replaceable Units (CRUs) can be replaced on Sun SPARC Enterprise[TM] M3000/M4000/M5000/M8000/M9000 systems using one of three possible replacement methods:
-
Cold Replacement
-
Hot Replacement
-
Active Replacement
This document is Step 5 of Document 1002526.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000: Field Replaceable Unit (FRU) Service Action Plan Reference.
Regarding Hard Disk Drive (HDD) Replacement Methods
If the HDD is the boot device, it will have to be replaced using cold replacement procedures. However, active replacement can be used if the boot disk can be isolated from the Oracle Solaris OS by disk mirroring software and other software.
Steps to Follow
Cold Replacement Method requires all domains and the entire platform be shut down and powered off in order to replace the FRU/CRU. Every FRU/CRU in Mx000 platforms can be Cold Replaced, but some must be replaced using this method.
Cold Replacement Method
The components which must be Cold Replaced on M3000 are:
MBU_A MBU_A_2 DIMM PCIe HDDBP
PSU DVDU FAN_A FANBP_B OPNL
The components which must be Cold Replaced on M4000/M5000 are:
MBU_A MBU_B CPUM MEMB DIMM
DDC_A DDC_B XSCFU IOU DDCR
FANBP_A FANBP_B FANBP_C BPU_A BPU_B
HDDBP TAPEBP DVD DVDBP_A DVDBP_B
OPNL
The components which must be Cold Replaced on M8000/M9000 are:
XBU_B CLKU_B OPNL SNSU ACS_A
ACS_B ACS_C ACS_D ACSTPH_A ACSTPH_B
ACSTPH-C ACSTPH-D BP_A BP_B PSUBP_A
PSUBP_B FANBP_A FANBP_B FANBP_C MEDBP
SWBP RDPF
The following steps are simply a reference to make one aware of what is involved in the Cold Replacement Method process, but the Service Manual is the authoritative resource for the actual process to be followed.
-
Shut down all applications (if running) on all domains on platform.
-
Shut down all domains.
-
Power off the platform.
-
Unplug the power cords (Make sure to be at the same potential as the system).
-
Initiate FRU replacement.
-
Power on the platform and verify FRU replacement is successful.
-
Bring domains and applications back online.
Hot Replacement Method
Hot Replacement Method requires that the domain(s) containing the faulty FRU/CRU be shut down in order to replace it. The remainder of the platform can stay in operation during the service period. Fans and PSUs are not part of domains and can therefore be replaced while all domains are running. Special rules apply for these FRUs to guarantee redundancy during the replacement operation, they are described later in this document.
The components which can be Hot Replaced on M3000 are:
FAN_A HDD PSU
The components which can be Hot Replaced on M4000/M5000 are:
HDD
The components which can be Hot Replaced on M8000/M9000 are:
CMU CPUM_A CPUM_B DIMM IOU
PCICS IOUA PCIB-EX XSCFU_B XSCFU_C
PSU FAN_A FAN_B DDC_A
DVDU TAPEU
The following steps are simply a reference to make one aware of what is involved in the Hot Replacement Method process, but the Service Manual is the authoritative resource for the actual process to be followed.
-
Shut down applications (if running) on domains that contain the FRU.
-
Shut down domains that contain the FRU.
-
Initiate FRU/CRU replacement.
-
Verify FRU/CRU replacement is successful.
-
Bring affected domains and applications back online.
Active Replacement Method
Active Replacement Method can only be used on redundantly configured FRUs/CRUs that can be Dynamically Reconfigured (DR) into or out of a domain. No interruption to domain or platform operations will occur when utilizing this method. Fans and PSUs are not part of domains and can therefore be replaced while all domains are running
NOTE: Active Replacement was not available until
XCP 1050.
The components which can be Active Replaced on M3000 are:
HDD PSU FAN_A
The components which can be Active Replaced on M4000/M5000 are:
PCICS PSU PCIB-EX HDD TAPE
The components which can be Active Replaced on M8000/M9000 are:
CMU CPUM_A CPUM_B DIMM IOU
HDD PCICS IOUA PCIB-EX XSCFU_B
XSCFU_C DVDU TAPEU PSU FAN_A
FAN_B DDC_A
The following steps are simply a reference to make one aware of what is involved in the Active Replacement Method process, but the Service Manual is the authoritative resource for the actual process to be followed.
-
Verify the FRU is redundantly configured in all domains in which this FRU is configured.
-
Verify the FRU and all dependent hardware on the FRU (I/O adapters, etc) are inactive.
-
Verify that resources are switched to alternate paths (I/O, network, etc) if necessary. This may include breaking disk mirrors or utilizing multi-pathing software to perform the actions.
-
Initiate FRU/CRU replacement utilizing Dynamic Reconfiguration.
-
Verify FRU/CRU replacement is successful.
-
Verify that any inactivated paths are re-enabled for all affected domains. This may include syncing disk mirrors or utilizing multi-pathing software to perform the actions.
-
Verify that the affected domains and applications are all still online without issues.
FRU List Tables
Sun SPARC Enterprise M3000
|
Component |
Description |
Cold Replacement |
Hot Replacement |
Active Replacement |
FRU/CRU
And Action Plan
|
MBU_A |
Motherboard Unit (M3000) |
Yes |
No |
No |
FRU
CAP 1293770.1
|
Dimm |
Main Memory DIMM |
Yes |
No |
No |
FRU
CAP 1290218.1
|
PCIe |
PCIe Card |
Yes |
No |
No |
FRU
CAP 1290151.1
|
HDD |
Hard Disk Drive |
Yes |
Yes |
Yes if Mirrored |
CRU
AP 1290205.1
|
HDDBP |
Hard disk drive backplane |
Yes |
No |
No |
FRU
CAP 1290180.1
|
DVDU |
CD-RW/DVD-RW drive unit |
Yes |
No |
No |
FRU
CAP 1292446.1
|
PSU |
Power Supply Unit |
Yes |
Yes |
Yes |
CRU
AP 1315095.1
|
FAN_A |
Fan |
Yes |
Yes |
Yes |
FRU
CAP 1290538.1
|
FANBP_B |
Fan backplane |
Yes |
No |
No |
FRU
|
OPNL |
Operator Panel |
Yes |
No |
No |
FRU
CAP 1290220.1
|
Sun SPARC Enterprise M4000/M5000
|
Component
|
Description
|
Cold Replacement
|
Hot Replacement
|
Active Replacement
|
FRU/CRU
|
MBU_A
|
Motherboard Unit (M4000)
|
Yes
|
No
|
No
|
FRU
CAP 1310975.1
|
MBU_B
|
Motherboard Unit (M5000)
|
Yes
|
No
|
No
|
FRU
CAP 1310968.1
|
DDC_A
|
DC-DC Converter (Motherboard and IO Unit)
|
Yes
|
No
|
No
|
FRU
CAP 1291514.1
|
DDC_B
|
DC-DC Converter with metal heatsink (Motherboard and IO Unit)
|
Yes
|
No
|
No
|
FRU
CAP 1291514.1
|
CPUM
|
CPU Module Unit
|
Yes
|
No
|
No
|
FRU
CAP 1310852.1
|
MEMB
|
Memory Board
|
Yes
|
No
|
No
|
FRU
CAP 1310994.1
|
DIMM
|
Main Memory DIMM (1, 2, or 4GB)
|
Yes
|
No
|
No
|
FRU
CAP 1310901.1
|
XSCFU
|
eXtended System Control Facility Unit
|
Yes
|
No
|
No
|
FRU
CAP 1310979.1
|
IOU
|
I/O Unit
|
Yes
|
No
|
No
|
FRU
CAP 1310950.1
|
DDCR
|
I/O DC Riser
|
Yes
|
No
|
No
|
FRU |
PCICS
|
PCI Cassette (including PCI card)
|
Yes
|
Yes
|
Yes
|
FRU
CAP 1310986.1
|
PCIB-EX
|
I/O Box Down Link Card
|
Yes
|
Yes
|
Yes
|
FRU
Copper CAP 1310920.1
Fibre CAP 1310912.1
|
FAN_A
|
172mm Fans
|
Yes
|
No
|
Yes, One unit at a time to support redundancy
|
FRU
CAP 1290538.1
|
FAN_B
|
60mm Fan (M4000)
|
Yes
|
No
|
Yes, One unit at a time to support redundancy
|
FRU
CAP 1290538.1
|
FANBP_A
|
172mm Fan Backplane (M4000)
|
Yes
|
No
|
No
|
FRU
CAP 1310821.1
|
FANBP_B
|
60mm Fan Backplane (M4000)
|
Yes
|
No
|
No
|
FRU
CAP 1310831.1
|
FANBP_C
|
172mm Fan Backplane (M5000)
|
Yes
|
No
|
No
|
FRU
CAP 1310823.1
|
PSU
|
Power Supply Unit
|
Yes
|
No
|
Yes, One unit at a time to support redundancy
|
CRU
AP 1315095.1
|
BPU_A
|
I/O Backplane / Power Backplane (M4000)
|
Yes
|
No
|
No
|
FRU
CAP 1310839.1
|
BPU_B
|
Bus Bar / I/O Backplane / Power Backplane (M5000)
|
Yes
|
No
|
No
|
FRU
CAP 1310825.1
|
HDD
|
73GB Hard Disk Drive
|
Yes
|
Yes
|
Yes, if mirrored
|
CRU
AP 1310916.1
|
HDDBP
|
Hard Disk Drive backplane
|
Yes
|
No
|
No
|
FRU
M4000 CAP 1310846.1
M5000 CAP
|
TAPE
|
DAT Tape Drive (Optional)
|
Yes
|
No
|
Yes
|
FRU
CAP 1310926.1
|
TAPEBP
|
DAT Tape Drive Backplane
|
Yes
|
No
|
No
|
FRU
M4000 CAP
M5000 CAP 1310811.1
|
DVD
|
DVD Drive
|
Yes
|
No
|
No
|
FRU
CAP 1310944.1
|
DVDBP_A
|
DVD Drive Backplane (M4000)
|
Yes
|
No
|
No
|
FRU
CAP 1310833.1
|
DVDBP_B
|
DVD Drive Backplane (M5000)
|
Yes
|
No
|
No
|
FRU
CAP 1310833.1
|
OPNL
|
Operator Panel
|
Yes
|
No
|
No
|
FRU
CAP 1310934.1
|
The information in the table above comes from the Sun SPARC Enterprise M4000/M5000 Servers Service Manual, Appendix C.
Sun SPARC Enterprise M8000/M9000 FRU Replacement Options
|
FRU
|
Description
|
Cold Replacement
|
Hot Replacement
|
Active Replacement
|
CMU
|
CPU Memory Board Unit
|
Yes
|
Yes
|
Yes
|
CPUM_A
|
CPU Module
|
Yes
|
Yes
|
Yes
|
CPUM_B
|
CPU Module
|
Yes
|
Yes
|
Yes
|
DIMM
|
Main Memory DIMM
|
Yes
|
Yes
|
Yes
|
IOU
|
I/O Unit
|
Yes
|
Yes
|
Yes, when redundantly configured. (Uses DR)
|
HDD
|
Hard Disk Drive
|
Yes
|
No
|
Yes, if mirrored
|
PCICS
|
PCI Cassette (including PCI board)
|
Yes
|
Yes
|
Yes, when multi path is configured.
|
IOUA
|
On board Device Card
|
Yes
|
Yes
|
Yes, if boot disks are mirrorred and multipathed
|
PCIB-EX
|
I/O Box Down Link Card
|
Yes
|
Yes
|
Yes
|
XBU_B
|
Crossbar Units
|
Yes
|
No
|
No
|
CLKU_B
|
Clock Control Units
|
Yes
|
No
|
No
|
XSCFU_B
|
XSCF Units (Base Cabinet)
|
Yes
|
Yes
|
Yes
|
XSCFU_C
|
XSCF Unit (M9000 Expansion Cabinet)
|
Yes
|
Yes
|
Yes
|
DVDU
|
DVD Drive Unit
|
Yes
|
Yes
|
Yes
|
TAPEU
|
Tape Drive Unit
|
Yes
|
Yes
|
Yes
|
OPNL
|
Operator Panel
|
Yes
|
No
|
No
|
SNSU
|
Sensor Unit
|
Yes
|
No
|
No
|
PSU
|
Power Supply Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
Yes, One unit at a time to support redundancy
|
ACS_A
|
AC Section Single Phase (M8000)
|
Yes
|
No
|
No
|
ACS_B
|
AC Section Single Phase (M9000) and Optional Dual Power Feed Power Cabinet
|
Yes
|
No
|
No
|
ACS_C
|
AC Section Single Phase Dual Power Feed Option (M8000)
|
Yes
|
No
|
No
|
ACS_D
|
AC Section (3-Phase Dual Power Feed)
|
Yes
|
No
|
No
|
ACSTPH_A
|
M8000 3-Phase Delta Dual feed
|
Yes
|
No
|
No
|
ACSTPH_B
|
M8000 3-Phase Star Dual feed
|
Yes
|
No
|
No
|
ACSTPH_C
|
M9000 3-Phase Delta Dual feed
|
Yes
|
No
|
No
|
ACSTPH_D
|
M9000 3-Phase Star Dual feed
|
Yes
|
No
|
No
|
FAN_A
|
3 Fan Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
Yes, One unit at a time to support redundancy
|
FAN_B
|
2 Fan Unit
|
Yes
|
Yes, One unit at a time to support redundancy
|
Yes, One unit at a time to support redundancy
|
BP_A
|
Backplane (M8000)
|
Yes
|
No
|
No
|
DDC_A
|
DC-DC Converter (only found in M8000)
|
Yes
|
Yes
|
Yes
|
BP_B
|
Backplane (M9000)
|
Yes
|
No
|
No
|
PSUBP_A
|
PSU Backplane (M9000)
|
Yes
|
No
|
No
|
PSUBP_B
|
PSU Backplane (M8000)
|
Yes
|
No
|
No
|
FANBP_A
|
Fan Backplane (M9000)
|
Yes
|
No
|
No
|
FANBP_B
|
Fan Backplane (M9000)
|
Yes
|
No
|
No
|
FANBP_C
|
Fan Backplane (M8000)
|
Yes
|
No
|
No
|
MEDBP
|
Media Backplane
|
Yes
|
No
|
No
|
SWBP
|
Switch Backplane
|
Yes
|
No
|
No
|
RDPF
|
Rack Mountable Dual Feed Option (M8000)
|
Yes
|
No
|
No
|
See Bug 15604747 for details on why the M4000/M5000 systems do not use hot replacement methods for FAN and PSU
Previously Published As 87405
Attachments
This solution has no attachment