Asset ID: |
1-71-1003374.1 |
Update Date: | 2017-05-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1003374.1
:
Guide to Serial ports on Sun Fire[TM] V210 and V240 servers
Related Items |
- Sun Fire V240 Server
- Sun Fire V210 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
- _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
|
PreviouslyPublishedAs
204710
Applies to:
Sun Fire V210 Server - Version All Versions and later
Sun Fire V240 Server - Version All Versions and later
All Platforms
Goal
Description
Sun Fire[TM] V210 and Sun Fire[TM] V240 servers have two serial ports, labelled SERIAL MGT and 10101.
Which serial port should I use?
Fix
Steps to Follow
On a Sun Fire[TM] V210/v240 the SERIAL MGT port accepts an RJ-45 connector.
This port is designed for Advanced Lights Out Management (ALOM) and system console use only.
Note: Do not attach any general purpose serial devices such as serial printer, UPS, modem to this
port.
The port labeled 10101 accepts a DB-9connector, this is the port to be used for general purpose serial data transfer.
The default serial connection settings are listed as shown:
Parameter |
Setting |
Connector |
SERIAL MGT or 10101 |
Rate |
9600 baud |
Parity |
None |
Stop bits |
1 |
Data bits |
8 |
If you need to connect to the SERIAL MGT port using either a DB-9 or a DB-25 connector, use an adapter to perform the crossovers given as shown:
RJ-45 to DB-9 Adapter Crossovers |
|
Serial Port (RJ-45 Connector) |
Pin Adapter (DB-9) Pin |
1 (RTS) |
8 (CTS) |
2 (DTR) |
6 (DSR) |
3 (TXD) |
2 (RXD) |
4 (Signal Ground) |
5 (Signal Ground) |
5 (Signal Ground) |
5 (Signal Ground) |
6 (RXD) |
3 (TXD) |
7 (DSR) |
4 (DTR) |
8 (CTS) |
7 (RTS) |
RJ-45 to DB-25 Adapter Crossovers |
|
Serial Port (RJ-45 Connector) |
Pin Adapter (DB-25) Pin |
1 (RTS) |
5 (CTS) |
2 (DTR) |
6 (DSR) |
3 (TXD) |
3 (RXD) |
4 (Signal Ground) |
7 (Signal Ground) |
5 (Signal Ground) |
7 (Signal Ground) |
6 (RXD) |
2 (TXD) |
7 (DSR) |
20 (DTR) |
8 (CTS) |
4 (RTS) |
Product
Sun Fire V240 Server
Sun Fire V210 Server
V210, V240, Enchilada, Serial Port, ALOM
Previously Published As
73815
Change History
Date: 2010-10-12
User Name: Silvana Villamil
Action: process comments
Comments: audited/updated by Silvana Villamil, Entry Level SPARC Content Team Member
Expanded acronym ALOM
Publishing
Version: 4
Date: 2005-01-04
User Name: 72228