Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1002631.1
Update Date:2017-08-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  1002631.1 :   Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  

PreviouslyPublishedAs
203630


Applies to:

Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later
Sun SPARC Enterprise M4000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
All Platforms

Goal

The intent of this document is to provide the reader with the available versions of the Sun SPARC(R) Enterprise M3000, M4000, M5000, M8000, and M9000 XCP Firmware Image software (XCP) and to inform where and how to obtain the appropriate images.

To cross reference bugs to the XCP versions containing the fix, please refer to "SPARC Enterprise M3000/M4000/M5000/M8000/M9000 - XCP Firmware to Defect Cross Reference".

To view the table with supported hardware, firmware and operating system (OS) combinations, as well as required software patches for M-series servers, please read "SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server Matrix for Hardware, Firmware and Software (Doc ID 1145383.1)" .

XCP firmware consists of three components, the XSCF firmware, the OpenBoot PROM (OBP) firmware and the Power On Self Test (POST) firmware. After downloading the appropriate patch for your system, download the XCP image onto your XSCF using either the Browser User Interface (BUI) or the getflashimage command. After succesfully downloading the XCP image onto the XSCF, run the flashupdate command to install the new XCP firmware onto the XSCF. Finally, in case the update contains a new version of POST or OBP, each domain needs to be rebooted to activate the new POST/OBP. For more details, please refer  to the Browser Users Interface (BUI) ,  getflashimage and flashupdate  documentation.

Please refer to the available XSCF user guide and release notes for: M8000 / M9000 Product Library Index , M4000 / M5000 Product Library Index and M3000 Product Library Index

 

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - M Series Servers

Solution

 

Steps to Follow
The XSCF Control Package firmware image (or XCP for short) is the software image that is downloaded and installed on to a Sun SPARC Enterprise M3000 through M9000 Extended System Control Facility Unit (XSCFU) enabling the XSCFU to function as a Service Processor.

Once downloaded the patch will contain the XCP image named:

     The M3000 XCP image (i.e.  IKXCP.tar.gz )

     The M4000/M5000 XCP image (i.e.  FFXCP.tar.gz )

     The M8000/M9000 XCP image (i.e.  DCXCP.tar.gz )

It is very important that the M3000 XCP image or M4000/M5000 XCP image are not installed on a Sun SPARC  Enterprise M8000/M9000 XSCF and vice versa.

SNMP MIB and other optional files will now be included within the patch package.  It is important to read and understand the SNMP documentation and added functionality of this package prior to installing and enabling the SNMP MIB package.  

NOTE: XCP 1093 is the minimum requirement for a domain running Solaris 10 9/10 with the processor groups observability feature enabled. Please refer to Solaris 10 9/10 Product Notes for more details about this feature.

The following matrix identifies which XCP firmware images are available and where to obtain them:

 

 

XCP Release

OpenBoot Prom(1)
XSCF(1)

POST
OBP

Date Available


Download Location

Notes

XCP1123

02.32.0000

01.12.0003

Post 2.17.0

4.33.5.d

Jul 2017

M3000 26433286
M4000 26433106
M5000 26433137
M8000 26433346
M9000 26433366
  • 25615557 Fix for CVE-2017-3732
  • 25690829 Domain side NTP can't sync up with NTP server via DSCP
  • 25750371 Problem with CLI
  • 25794728 Problem with CLI
  • 26044636 Fix for CVE-2016-6515
  • 26045416 Update to tzdata-2017b
  • 26045445 Truncated snmp log file during boot up
  • 26081214 Problem in OPL-ALL/Security
  • 26081220 Problem in OPL-ALL/Security
XCP1121 02.32.0000

01.12.0001

Post 2.17.0

4.33.5.d

Feb 2016

M3000 22725261
M4000 22725267
M5000 22725271
M8000 22725276
M9000 22725281

  • 22177306 SNMP state changes to disable by any change of snmpv3 settings
  • 18808357 XSCF SNMP answer to scfComponentStatus takes upto 1 hour
  • 21182328 CVE-2015-4000
  • 21033696 CVE-2015-2566
  • 22099923 CVE-2015-2808
  • 22250709 CVE-2015-3238
  • 22381491 CVE-2015-1789
XCP1120

02.32.0000

01.12.0000

Post 2.17.0

4.33.5.d

M3000-M9000

July 2015


Not Available - Obsoleted by 1123

 Bug Fixes:  19880721, 20460828, 20412206, 20953771
XCP1119

02.32.0000

01.11.0009

POST 2.17.0

4.33.5.d

M3000-M9000

January 2015


Not Available - Obsoleted by 1121

Bug fixes: 19796249, 19842625, 20106389

XCP1118

02.32.0000

01.11.0008

POST 2.17.0

4.33.5.d

M3000-M9000

October 2014


Not Available - Obsoleted by 1120

Bug fixes: 17544453, 18227397,18879056, 18923614, 19279982, 19695980

XCP1117

02.32.0000

01.11.0007

POST 2.17.0

4.33.5.d

M3000 - M9000

February 2014


Not Available - Obsoleted by 1119

Bug fixes: 18183768, 18164678, 17348428, 17337119
XCP1116

02.32.0000

01.11.0006

POST 2.17.0

4.33.5.d

M3000 - M9000

August 2013


Not Available - Obsoleted by 1118

Bug fixes: 16011251, 16825834, 16978703, 17062578, 17179848,  17179990, 17193451, 17284889

New features: support for 2048-bit SSL certificates

XCP1115 02.32.0000
01.11.0005
POST 2.17.0
4.33.5.d

M3000 - M9000
April 2013

Obsoleted by XCP1116 - See 1564729.1 for more information on issues with this release.

Bug fixes:  15891122, 15818191, 15818189, 15807140, 15789531, 15757233, 16447982, 16457527, 15921263, 15820827, 16006105, 16242988, 16247278

tzdata
XCP1114
EOL

02.32.0000
01.11.0004

POST 2.17.0
4.33.5.d

M3000 - M9000
November 2012

Not Available - See 1538391.1 for more information on issues with this release.

Bug fixes : 6750732, 7058986, 7154759, 7072870, 7147503, 7142507, 7189317, 7032793, 7081753, 6931105, 7048572, 7187299, 7187556, 7203054, 7193189

tzdata2012c

XCP1113
EOL

02.29.0000
01.11.0003

POST 2.17.0
4.33.5.a

M3000 - M9000
July 2012


Not Available - Obsoleted by 1116

Bug fixes :  7159171, 7132774, 7112173, 7160215, 6778374, 7154883, 7166651, 7087685, 7167659, 7180251

tzdata2011h

XCP 1112
EOL
02.29.0000
01.11.0002
POST 2.17.0
4.33.5.a

M3000 - M9000
May 2012


Not Available - Obsoleted by 1114

Bug fixes : 7162656

New features : support for RAID-capable IOUA cards on M8000/M9000


tzdata2011h

XCP 1111
EOL
02.29.0000
01.11.0000
POST 2.17.0
4.33.5.a
M3000 - M9000 
April 2012

 

Not Available - Obsoleted by 1112

 

Bug fixes : 7150657

tzdata2011h

XCP 1110
EOL

02.29.0000
01.11.0000

POST 2.17.0
4.33.5.a

M3000 - M9000
February 2012

 

Not Available - Obsoleted by 1111

Bug fixes :  7046697, 7051222, 7012224, 7025452, 6877010, 7041235, 7041257, 7041570, 7066459, 7082602, 7072071, 7031894, 7069669, 7022369, 7038672, 7067503, 7117307, 7088671, 7098709, 7058615, 7078677, 7043769, 7090809, 7080011, 7096831
7082446, 7114369, 7113480, 7092822, 7113201, 7147503, 7142507

tzdata2011h

XCP 1102
EOL

02.24.0000
01.10.0002

POST 2.15.0
4.33.0.a

M3000 - M9000
June 2011



Not Available - Obsoleted by 1112

Bug fixes: 7003451, 6992773, 7001257, 7022594, 6923186, 6971172, 6982845, 7006542, 7019526, 7013075, 6999483, 7021241, 7018096, 6818189, 6907290, 7020683, 7042939, 7036027, 7037757, 7042804

New features:  non-zero headroom value now results in a COD violation, Customers using the Sun Flash Accelerator F20 PCIe Card must upgrade to xcp1102 as soon as
possible.

tzdata-2010m

XCP 1101
EOL

02.21.0000
01.10.0001

POST 2.15.0
4.24.16

M3000 - M9000
Mar 2011



Not Available - Obsoleted by 1110

Bug fixes: 7010894, 7013390, 6815259, 6923191, 6940532, 6982003, 6983908, 6986188, 6995112, 6791431, 6883796, 6931093, 6931096, 6939949, 6946029, 6988801, 6993151, 6994665, 7000103, 7002609, 7003622, 7007416, 7008908, 7009226, 7010255

New features: 
Support for a new COD permit delivery system (unlocked COD keys / Oracle's E-Delivery process / no more support for headroom).

tzdata-2010m

XCP 1100
EOL

02.18.0000
01.10.0000

POST 2.14.0
4.24.15

M3000 - M9000
Dec 2010



Not Available - Obsoleted by 1102

Bug fixes: 6946028, 6946490, 6996000, 7002314, 6908805, 6913284, 6918829, 6921574, 6927116, 6939537, 6940073, 2193754, 2193937, 2194039, 2194051, 2194335, 6670662, 6791410, 6933792, 6941944, 6946487, 6952619, 2194446, 2195170, 2195421, 6927721, 6940535, 6942144, 6960111, 6961919, 6966764, 6905441, 6913987, 6914053, 6914377, 6921571, 6929944, 6967001, 6971514, 6984765, 6797558

New features: 
SPARC64 VII+ processor on the M4000-M9000 Servers.
Airflow indicator feature for M4000/M5000 Servers.

XCP 1093
EOL

02.16.0000
01.09.0003

POST 2.14.0
4.24.14

M3000-M9000
Aug 2010



Not Available - See <Document 1220873.1> from more information on issues with this release. 

Bug fixes: 6940544, 6962007, 6962929, 6896055, 6930008, 6938653, 6940788, 6952185

Changes to COD Terminology: Please refer to the on-line documentation web site M3000, M4000/M5000, M8000/M9000

New features: Support for Sun Flash Accelerator F20 PCIe Card

XCP 1092
EOL

02.14.0000
01.09.0002

POST 2.13.0
4.24.13

M3000-M9000
Apr 2010





Not Available - See <Document 1220873.1> from more information on issues with this release.

Bug fixes: 6929639, 6935346, 6936544, 6693778, 6771052, 6794232, 6796931, 6819296, 6861630, 6862682, 6868683, 6870490, 6875462, 6882249, 6885085, 6885581, 6888497, 6888970, 6888976, 6888979, 6889884, 6890817, 6891316, 6893578, 6894238, 6894382, 6894410, 6896929, 6897059, 6898758, 6898759, 6900533, 6902766, 6902772, 6904626, 6905442, 6907182, 6907184, 6911309, 6906738, 6909448, 6911218, 6913019, 6913991, 6916641

New features:  Support for Packet Filtering.  See new manpages for setpacketfilters(8) and showpacketfilters(8).

XCP 1091
EOL

02.13.0000
01.09.0001

POST 2.13.0
4.24.12

M3000-M9000
Nov 2009



NA

Bug fixes: 6794811, 6808531, 6810902, 6818718, 6828477, 6830790, 6838671, 6847019, 6847963, 6851009, 6852765, 6858201, 6858203, 6864416, 6867706, 6867707, 6869796, 6869800, 6870846, 6871640, 6875469, 6882322, 6852845, 6862966, 6865485, 6870726, 6875804, 6879471, 6880064, 6882256, 6882309, 6882313, 6885007, 6889382, 6889875, 6893981, 6897059
New features: Active Directory, LDAP over SSL

XCP 1090
EOL

02.11.0000
01.09.0000

POST 2.11.0
4.24.11

M3000-M9000
Aug 2009




NA

Bug fixes: 6693088, 6723884, 6741855, 6768750, 6867325, 2174505, 6636243, 6669346, 6704911, 6729779, 6751151, 6756464, 6773905, 6789847, 6802613, 6808532, 6814729, 6823219, 6828180, 6829233, 6829718, 6831733, 6835875, 6581684, 6639445, 6757614, 6801549, 6827259, 6849208, 6849663, 6635693, 6783961, 6829469, 6845285, 6845781, 6856272
New features: SPARC64 VII 2.88 GHz processor, showdateoffset(8), Airflow Indicator

XCP 1082
EOL

02.09.0000
01.08.0005

POST 2.9.0
OBP 4.24.10

M3000-M9000
May 2009




NA

Bug fixes: 6714850, 6614835, 6608959, 6652700, 6749184, 6698356, 6772115, 6745304, 6789113, 6623945, 6626187, 6623949, 6667077, 6589414, 6742502, 6790005, 6584843, 6742395, 6713810, 6582835, 6801476, 6799922, 6633118, 6775857, 6793901, 6797557, 6786707, 6812005, 6816465,6735711, 6814728, 6744013, 6786770, 6745289, 6734322, 6778132, 6756052, 6765466, 6767612, 6763349, 6717438, 6635040, 6801356, 6805455, 6821960, 6772115

XCP 1081
EOL

02.08.0000
01.08.0004

POST 2.8.0
OBP 4.24.10

M3000-M9000
Feb 2009




NA

Bug fixes: 6601940, 6635040, 6635040, 6635059, 6635059, 6644091, 6644971, 6668290, 6675409, 6711260, 6716495, 6732712, 6742457, 6743183, 6743842, 6747279, 6749980, 6754066, 6754071, 6754508, 6755986, 6757776, 6759468, 6759532, 6759987, 6762110, 6764855, 6767417, 6769868, 6772968, 6773750, 6775856, 6776532, 6788348

Key features :
New feature: power management support for M3000, setloginlockout / showloginlockout commands

XCP 1080
EOL

02.07.0000
01.08.0002

POST 2.7.0
OBP 4.24.10

M3000
31st Oct 2008
M4000-M9000
mid Nov 2008









NA

Bug fixes: 6575425, 6645571, 6669361, 6682936, 6685724, 6696502, 6705870, 6740203, 6579253, 6618498, 6644490, 6687545, 6687663, 6694376, 6695866, 6699196, 6700019, 6700025, 6700779, 6703402,6681287, 6698396, 6702492, 6706213, 6706348, 6712009, 6723546, 2161838, 2164613, 6523740, 6664134, 6682929, 6688868, 6695841, 6695890, 6701659, 6702356, 6708053, 6709255, 6711370, 6714164, 6716494, 6716864, 6718189, 6718649, 6721895, 6723773, 2162599, 2164611, 2164612, 2165373, 2165579, 2165840, 2166682, 6596993, 6614427, 6627865, 6653783, 6665174, 6669369, 6678956, 6679286, 6689632, 6704043, 6709441, 6712056, 6713429, 6713787, 6716551, 6717594, 6723419, 6725315, 6725809, 6728737, 6729224, 6729758, 6729773, 6729776, 6729856, 6730225, 6734057, 6737740, 2166507, 6620681, 6674742, 6716103, 6723195, 6738494, 6738503, 6739070, 6739071, 6740099, 6741074, 6742279, 6742337, 6743116, 6747138, 6749184    
 
Key features : Support for M3000 servers
New features: off-platform backup and restore of XSCF configuration / dumpconfig/restoreconfig commands, ping command, traceroute command

XCP 1072
EOL

02.03.0000
01.07.0005

POST 2.3.0
OBP 4.24.8

M4000-M9000
Sep 2008



NA

Bug fixes: 2162561, 2162783, 2162874, 2163001, 2163491, 2164098, 2164855, 6667692, 6680705, 6693898, 6700185, 6700222, 6705272, 6709701, 6722617, 6723549
 
Key features :
New feature:

XCP 1071
EOL

02.03.0000
01.07.0001

POST 2.3.0
OBP 4.24.8

M4000-M9000
Jun 2008




NA

Bug fixes: 2161616, 2162988, 6473379, 6528600, 6543189, 6545482, 6559060, 6566540, 6571840, 6574841, 6583053, 6588200, 6589870, 6590866, 6598444, 6612827, 6615720, 6618833, 6626181, 6626183, 6626779, 6626912, 6628419, 6630959, 6632063, 6635895, 6641765, 6641768, 6645828, 6654373, 6655686, 6660264, 6661840, 6664046, 6666291, 6667088, 6667626, 6668614, 6677063, 6677958, 6683763, 6685374, 6685379
 
Key features : Support for SPARC64 VII processors
New feature: restoredefaults command

XCP 1070
EOL

02.02.0000
01.07.0000

POST 2.2.0
OBP 4.24.7

M8000-M9000
Apr 2008



NA

This version is released only for M8000 / M9000
For M4000 / M5000, use XCP 1061
Bugs fixes: 6623867, 6625938, 6636985, 6639902, 6570300, 6661123, 6654344, 6652686, 6649341
Key features : Support for SPARC64 VII processors

XCP 1061
EOL

01.30.0000
01.06.0002

POST 1.24.0
OBP 4.24.4

M4000-M9000
Feb 2008

1. If you are on FW 1050 or newer, you can go to any new FW

2. If you are on FW 104x, you need to upgrade to an interim FW between 1050 and 1070 before going to the latest.

3. The Only Interim FW made available is 1061.

To obtain XCP1061 open a Service Request.

Bugs fixes. 6645572, 6645570, 6645560, 6639839, 6639902
Key features :

XCP 1060
EOL

01.30.0000
01.06.0001

POST 1.24.0
OBP 4.24.4

M4000-M9000
Dec 2007


NA

Bugs fixes.
Key features :
BUI enhancements (COD, maintenance), Faults clearing changes ...

XCP 1050
EOL

01.29.0000
01.05.0002

POST 1.24.0
OBP 4.24.3

M5000-M9000
Oct 2007


NA

Bugs fixes.
Key features :
COD, Dual SP, DR, setupplatform,fault clearing, enhanced BUI, Service Tags, Relaxed Ordering ...

XCP 1041
EOL

01.25.0000
01.04.0002

 

M4000-M9000
May  2007


NA

Bug fix release.  Contains no new features.  

Note(1):  As displayed by the  version -c xcp -v  command

 

 

Where to locate patches, updates, and/or firmware images?

Product patches, updates and firmware are available for download from My Oracle Support, on the Patches and Updates tab across the top of the page (below where your user name or email is displayed once logged in).
SEARCH TIPS:  Search for the patch using the Advanced Search option and choose to filter the results based on your system type:
For example choose Sun SPARC Enterprise M3000 or Sun SPARC Enterprise M8000 or whatever system you are looking for an image for.
After selecting the appropriate system, the next drop-down menu will ask you to sort through a list of XCP releases and select the desired release (we suggest the latest). 

After selecting the XCP version and clicking search,  a listing will appear that shows you the patch ID which you can open and download the firmware from.
Information on accessing and using My Oracle Support can be found at the My Oracle Support Welcome Center for Oracle Sun Customers and Partners.
 
 
 
 
Caution: XCP1050 is not supported on the M4000 due to a problem with perfectly good
fans being faulted see Document 1000497.1 Sun SPARC Enterprise M4000 Servers may
experience erroneous fan failures using XCP 1050.

If the customer's OpenBoot Prom and XSCF version do not match what is listed
above, then it is highly probable that the XSCF is installed with an Engineering
released XCP image to address specific issues.

TSC References:
       Firmware matrix
       XCP FAQ

The XCP1061 images for FF and DC are available from the TSC Firmware Matrix.
Previously Published As 89021
 

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback