Goal

This document is a quick reference to Lights Out Management (LOM) commands. It applies to LOMlite2 only.

Solution

alarmoff n

Sets alarm n off (where n is 1, 2, or 3). These three alarms are software flags. They are associated with no specific conditions, but are available to be set by your own processes.  The alarmoff command must have a space prior to the alarm #.

alarmon n    

Sets alarm n on. (See the description for the alarmoff command.)  The alarmon command must have a space prior to the alarm #.

break

Takes the server down to the ok prompt.

bootmode

Determines the behavior of the server during the boot process.

check

Resets monitoring to report all failures. If a monitored component has failed, the LOMlite2 device will not continue to report the same failure. For example, to check the status of the component after attempting to fix it, issue the check command. This updates the status of all monitored components.

console

This command takes you out of the LOMlite2 shell and back to the # prompt or ok prompt, depending on how you invoked the LOMlite2 shell. It returns control of the serial connection to the console.

environment

Displays the temperature of the server and the status of the fans, power supply over-temperature monitors, alarms, and fault LED.

faulton

Sets the Fault LED to On.

faultoff

Sets the Fault LED to Off.

help

Displays the list of LOM commands.

loghistory

Displays all the events in the LOMlite2 device s Event Log.

logout

For use by named users whom you have set up with password access to the LOMlite2 device. It returns them to the LOM user login prompt.

poweron

Powers the server on.

poweroff

Powers the server down to standby power mode.

reset

Resets the Netra 20 server.

show model

Displays the server model.

show hostname

Displays the server name (equivalent to the Solaris uname -n command).

show eventlog

Displays the LOMlite2 device s event log. The event log is the list of the last 10 events to have been stored in the LOMlite2 device. The most recent event is the one at the bottom of the list.

show escape

Displays the current LOMlite2 escape sequence.

show

Displays all the information available with the show command.

useradd

Adds a user to the LOMlite2 device s list of permitted users.

userdel

Deletes a user from the LOMlite2 device s list of permitted users.

usershow

Displays the details of a named user s LOMlite2 account.

userpassword

Sets or changes a user s password.

userperm

Sets the the permission levels for a named user.

version

Displays the version number of LOMlite2 device.