![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1001828.1 : How To Upgrade ALOM version and Related FAQ for V125, V210, V215, V240, V245, V250, V440, V445 and Netra 210, 240, 440 Servers
PreviouslyPublishedAs 202501 Applies to:Sun Netra 440 Server - Version All Versions and laterSun Fire V440 Server - Version All Versions and later Sun Fire V210 Server - Version All Versions and later Sun Fire V250 Server - Version All Versions and later Sun Fire V445 Server - Version All Versions and later All Platforms To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community, SPARC Legacy Servers. GoalThis article addresses frequently asked questions pertaining to Sun Advanced Lights Out Manager with respect to Sun Fire[TM] V125/Sun Fire[TM] V210/Sun Fire[TM] V215/Sun Fire[TM] V240/Sun Fire[TM] V245/Sun Fire[TM] V250/Sun Fire[TM] V440/Sun Fire[TM] V445 and Netra[TM] 210/Netra[TM] 240/Netra[TM] 440 servers. Solution
Q. What versions of Advanced Lights Out Management (ALOM) are available? A. Presently, versions 1.0, 1.1, 1.2, 1.3, 1.4, 1.5.x and 1.6 of ALOM are in use but only version 1.6 is available for download. Q. From where are new versions of ALOM obtained? A. Sun Advanced Lights Out Manager is available for download, the best way to get patches now is from MOS: - Login to MOS and go to the Patches & Updates tab. - In the "Patch Search" box select Search by "Number/Name or Bug Number" (default option) Q. How is ALOM installed? A. Obtain installation instructions from the downloaded ALOM package (see step A). Q. Is ALOM still available in the form of a patch? A. No, it was never a patch on SunSolve(SM). It is a download only. Q. Which versions of ALOM are required for Sun Fire and Netra systems? A. Refer to the following compatibility matrix: ALOM Hardware Operating min OBP Required Version Platform System Version Patches ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1.0 Sun Fire V210 Solaris 8 12/02 OBP 4.8.2 None Solaris 9 04/03 OBP 4.8.2 Sun Fire V240 Solaris 8 12/02 OBP 4.8.2 Solaris 9 04/03 OBP 4.8.2 1.1 Sun Fire V210 Solaris 8 12/02 OBP 4.8.2 None Solaris 9 04/03 OBP 4.8.2 Sun Fire V240 Solaris 8 12/02 OBP 4.8.2 Solaris 9 04/03 OBP 4.8.2 Sun Fire V440 Solaris 8 07/03 OBP 4.10.5 Solaris 9 12/03 OBP 4.10.5 1.2 Sun Fire V210 Solaris 8 07/03 OBP 4.11.4 None Solaris 9 04/03 OBP 4.11.4 Sun Fire V240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/03 OBP 4.11.4 Sun Fire V250 Solaris 8 07/03 OBP 4.11.4 Solaris 9 08/03 OBP 4.11.4 Sun Fire V440 Solaris 8 07/03 OBP 4.10.5 Solaris 9 12/03 OBP 4.10.5 1.3 Sun Fire V210 Solaris 8 07/03 OBP 4.11.4 None Solaris 9 04/03 OBP 4.11.4 Sun Fire V240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/03 OBP 4.11.4 Sun Fire V250 Solaris 8 07/03 OBP 4.11.4 Solaris 9 08/03 OBP 4.11.4 Sun Fire V440 Solaris 8 07/03 OBP 4.10.5 Solaris 9 12/03 OBP 4.10.5 Netra 240 Solaris 8 07/03 OBP 4.11.4 1.4 Sun Fire V210 Solaris 8 07/03 OBP 4.11.4 None Solaris 9 04/03 OBP 4.11.4 Sun Fire V240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/03 OBP 4.11.4 Sun Fire V250 Solaris 8 07/03 OBP 4.11.4 Solaris 9 08/03 OBP 4.11.4 Sun Fire V440 Solaris 8 07/03 OBP 4.10.5 Solaris 9 12/03 OBP 4.10.5 Netra 240 Solaris 8 07/03 OBP 4.11.4 Netra 440 Solaris 8 07/03 OBP 4.13.0 Solaris 9 12/03 OBP 4.13.0 1.5.x Sun Fire V210 Solaris 8 07/03 OBP 4.11.4 None Solaris 9 04/03 OBP 4.11.4 Sun Fire V240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/03 OBP 4.11.4 Sun Fire V250 Solaris 8 07/03 OBP 4.11.4 Solaris 9 08/03 OBP 4.11.4 Sun Fire V440 Solaris 8 07/03 OBP 4.10.5 Solaris 9 12/03 OBP 4.10.5 Netra 240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/04 OBP 4.11.4 Netra 440 Solaris 8 07/03 OBP 4.13.2 Solaris 9 12/03 OBP 4.13.2 1.6.x Sun Fire V125 Solaris 8 02/04 OBP 4.22.17 None Solaris 9 09/04 OBP 4.22.17 Sun Fire V210 Solaris 8 07/03 OBP 4.11.4 None Solaris 9 04/03 OBP 4.11.4 Sun Fire V215 Solaris 10 06/06 OBP 4.22.18 Solaris 9 09/05 OBP 4.22.18 Sun Fire V240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/03 OBP 4.11.4 Sun Fire V245 Solaris 10 06/06 OBP 4.22.18 Solaris 9 09/05 OBP 4.22.18 Sun Fire V250 Solaris 8 07/03 OBP 4.11.4 Solaris 9 08/03 OBP 4.11.4 Sun Fire V440 Solaris 8 07/03 OBP 4.10.5 Solaris 9 12/03 OBP 4.10.5 Sun Fire V445 Solaris 10 06/06 OBP 4.22.11 Solaris 9 09/05 OBP 4.22.11 Netra 210 Solaris 9 09/05 OBP 4.18.5 Solaris 10 03/05 OBP 4.18.5 Netra 240 Solaris 8 07/03 OBP 4.11.4 Solaris 9 04/04 OBP 4.11.4 Netra 440 Solaris 8 07/03 OBP 4.13.2 Solaris 9 12/03 OBP 4.13.2
NOTE: ALOM 1.6.x is the most recent and up-to-date version of this product. It has the latest platform support, support for updated system controller hardware and the latest bug fixes. It is the only release that supports all shipping hardware today. All prior versions should not be used on new shipping hardware and are no longer available on the Sun Download Center. NOTE: The OBP versions shown in the above matrix are just the minimum supported firmware versions. It is always recommended to upgrade to the latest FW versions, that can be found on MOS. NOTE: ALOM 1.6.x firmware have different download images. There is a download image for SunFire V215, V245, V445 and there is another image for the rest of the servers (see the second question above). NOTE: Downloading the main firmware image can take up to 10 minutes. The boot monitor (bootmon) image download process can take several minutes to complete. After the download is complete, ALOM automatically resets. ALOM resets should NOT cause an outage
This issue is addressed in Bug Id 4974479
References<NOTE:1004884.1> - How To Configure the ALOM "NET MGT" Port for Sun Fire V125, V210, V215, V240, V245, V250, V440, V445 and Netra 210, 240, 440 Servers<NOTE:1003595.1> - Sun Fire[TM] V440: ALOM commands and users failing after motherboard replacement <NOTE:1006084.1> - Advanced Lights Out Manager (ALOM) Commands <NOTE:1006640.1> - How To Get Explorer To Collect ALOM Data on V125/V210/V215/V240/V245/V440/V445 and Netra 210/240 Attachments This solution has no attachment |
||||||||||||
|