Asset ID: |
1-79-2343774.1 |
Update Date: | 2018-04-17 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2343774.1
:
Firmware Versions included in Big Data Appliance image 4.11.0
Related Items |
- Big Data Appliance X3-2 Hardware
- Big Data Appliance X4-2 Hardware
- Big Data Appliance X5-2 Hardware
- Big Data Appliance Hardware
- Big Data Appliance X7-2 Hardware
- Big Data Appliance X6-2 Hardware
|
Related Categories |
- PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: BDA
|
In this Document
Applies to:
Big Data Appliance X5-2 Hardware - Version All Versions and later
Big Data Appliance X6-2 Hardware - Version All Versions and later
Big Data Appliance Hardware - Version All Versions and later
Big Data Appliance X4-2 Hardware - Version All Versions and later
Big Data Appliance X7-2 Hardware - Version All Versions and later
Linux x86-64
Purpose
This document lists the firmware included in Big Data Appliance Image 4.11.0.
The firmware is not automatically updated during patching or image upgrading.
Firmware updating must be done manually via the 'bdaupdatefw' command. Refer to the reference section below.
Scope
This document lists the firmware included in Big Data Appliance Image 4.11.0 which was released Dec 2017.
Details
[bdanode01 ~]# imageinfo
Big Data Appliance Image Info
IMAGE_VERSION : 4.11.0
IMAGE_CREATION_DATE : Thu Dec 7 19:17:44 UTC 2017
IMAGE_LABEL : BDA_MAIN_LINUX.X64_171206
LINUX_VERSION : Oracle Linux Server release 6.9
KERNEL_VERSION : 4.1.12-103.9.7.el6uek.x86_64
BDA_RPM_VERSION : bda-4.11.0-1.el6.x86_64
JDK_VERSION : jdk1.8.0_141-1.8.0_141-fcs.x86_64
[bdanode01 ~]# ls /opt/oracle/bda/firmware
Disk-Hitachi-10TB-H7210A520.A374.fw
Disk-Hitachi-2TB-H7220AS60.A310.fw
Disk-Hitachi-3TB-H7230AS60.A310.fw
Disk-Hitachi-4TB-H7240AS60.A3A0.fw
Disk-Hitachi-4TB-H7240B520.M554.fw
Disk-Hitachi-8TB-H7280A520.P9E2.fw
Disk-Hitachi-8TB-H7280A520.PAG1.fw
Disk-Hitachi-8TB-H7280B524.C376.fw
Disk-Seagate-2TB-ST32000SS.061A.fw
Disk-Seagate-3TB-ST33000SS.064A.fw
fw-ConnectX2-rel-2_11_2010-be-375-3696-01.bin
fw-ConnectX3-rel-2_11_1280-e0-7046442.bin
fw-ConnectX-3-rel-2_11_3030-bc-7046442.bin
fw-ConnectX3-rel-2_35_5532-15-7046442_7092757.bin
HBA-12_12_0_0229-SAS-9261-8i.rom
HBA-24_15_0_0028-SAS-9361-8i.rom
HBA-24_3_0_0081-SAS-9361-8i.rom
HBA-24_3_0_0084-SAS-9361-8i.rom
HCA-rel-2_9_1000-MT26428.bin
ILOM-3.2.7.30.a_r112904-Sun_Fire_X4170M2_4270M2.pkg
ILOM-3_2_8_24_r114580-Oracle_Server_X5-2L.pkg
ILOM-3_2_8_24_r114611-Oracle_Server_X6-2L.pkg
ILOM-3_2_9_22_r115963-Sun_Fire_X4270_M3.pkg
ILOM-3_2_9_22_r115963-Sun_Server_X4-2L.pkg
ILOM-3_2_9_23_r116695-Oracle_Server_X5-2L.pkg
ILOM-3_2_9_23_r116695-Oracle_Server_X6-2L.pkg
ILOM-4_0_0_20_r120817-ORACLE_SERVER_X7-2L-rom.pkg
The firmware listed above can be identified by the prefix:
Disk : Hitachi and Seagate Hard Disk Drives
fw-ConnectX2 : Dual 40Gigabit/Sec (4x) QDR InfiniBand Host Channel Adapter M2 (Original and X3-2)
fw-ConnectX3 : Dual 40Gigabit/Sec (4x) QDR InfiniBand Host Channel Adapter M3 (X4-2 and later)
HBA-12 : 8-Port 6Gbps SAS-2 Internal RAID HBA (Original, X3-2, X4-2)
HBA-24 : 8-port or 16-Port 12Gbps SAS-3 Internal RAID HBA (X5-2 and later)
ILOM : BIOS and Service Processor firmware for the Server Nodes
References:
Big Data Appliance Owner's Guide: Oracle Big Data Appliance Utilities: bdaupdatefw
Document:1528190.1 - Firmware Upgrade Policy and Factory Ship Versions for Oracle Big Data Appliance Sun Fire X4270 M2, X3-2, X4-2,X5-2, and X6-2
References
<NOTE:1528190.1> - Firmware Upgrade Policy and Factory Ship Versions for Oracle Big Data Appliance Sun Fire X4270 M2, X3-2, X4-2,X5-2,X6-2 and X7-2
https://docs.oracle.com/bigdata/bda410/BIGOG/utilities.htm#GUID-F303EE9E-A18F-44A2-9735-EBB3DBB9822A <NOTE:2320709.1> - Firmware Versions included in Big Data Appliance image 4.10.1
Attachments
This solution has no attachment