![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2334909.1 : Netra T2000 SP can be replaced by a Sun Fire T2000 SP
Oracle Confidential PARTNER - Available to partners (SUN). Reason: Classification of related CAP Applies to:Sun Netra T2000 Server - Version All Versions and laterInformation in this document applies to any platform. PurposeThe number of service replacement SPs for the Netra T2000: 371-1962 are running low. This document provides a procedure to use replacement SPs from the Sun Fire T2000: 501-7130, 501-7500, or 501-7764 in a Netra system, since they use the same Printed Circuit Board. DetailsNote: that the user must still follow document 1308290.1 to replace the SP! There are 2 differences between the Netra T2000 & Sun Fire T2000 SPs, as follows:
Thus, the following steps must be modified or added: 5. Remove the ALOM card from the system board - Do not remove the right angle SP riser since the replacement will not contain one. 8. Insert the replacement ALOM into the System Board - Insert the replacement ALOM into the riser. Add - 12. Perform a firmware upgrade of the replaced ALOM with the desired Netra firmware patch, per 1011226.1.
Please see the attached serviceability .pdf that illustrates the replacement.
Attachments This solution has no attachment |
||||||||||||
|