Solution Type Predictive Self-Healing Sure Solution 2312387.1 : SPARC M8 and SPARC M7 Series Servers : Configuration rules
In this Document
Applies to:SPARC M7-8SPARC M8-8 SPARC M7-16 Information in this document applies to any platform. PurposeThe goal of this document is to provide hardware configuration rules about the SPARC M8 and SPARC M7 Series Servers. DetailsThe SPARC M7-8 server configured with two static PDomains is the only server that supports a mixed configuration of SPARC M7 and SPARC M8 CMIOUs. In a SPARC M7-8 server with two static PDomains, SPARC M8 CMIOUs can be installed in PDomain_1 (slots CMIOU_4 to CMIOU_7). SPARC M8 CMIOUs are not supported in PDomain_0 (slots CMIOU_0 to CMIOU_3) of a SPARC M7-8 server with two PDomains. Unsupported CMIOU configurations include:
A PDomain will not power on if it contains an unsupported configuration. If the PDomain contains an unsupported configuration, the host console will display an error message and the server will generate an ereport alerting you to the unsupported configuration. e.g.,
2016-10-04 18:04:41 SP> NOTICE: Exclude all of /HOST1. Reason: Mixing M7 and M8 in the same host You must fix the unsupported configuration by either removing or disabling the offending CMIOUs before you can power on the PDomain. Note - If the PDomain is running and you attempt to install a CMIOU that creates an unsupported CMIOU configuration (for example, if you install SPARC M8 CMIOU in a SPARC M7-16 server), the PDomain will continue to run. The server will generate an ereport alerting you to the unsupported configuration, and the new CMIOUs will not be added to the running PDomain. You must fix the unsupported configuration by either removing or disabling the offending CMIOUs before you can restart the PDomain.
A SPARC M7-8 server with a mixed CMIOU configuration must run a system firmware version that supports both SPARC M8 and SPARC M7 CMIOUs. Additionally, the server's PDomain_1 containing the SPARC M8 CMIOUs must be running an Oracle Solaris version that supports the SPARC M8 CMIOUs. For the minimum supported versions of the supported software and firmware, refer to the SPARC M8 and SPARC M7 Servers Product Notes or Doc ID 1967047.1.
Table 1: Supported CMIOU configurations
References<NOTE:1967047.1> - SPARC M8 and SPARC M7 Series Servers : Minimum supported Firmware, Software and Solaris patches pagehttp://docs.oracle.com/cd/E55211_01/html/E55216/index.html Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||
|