Solution  2305675.1 :   SUN4V-8002-XD - The number of faults on redundant devices has crossed the allowable threshold.  


Related Items
  • SPARC M7-8
  •  
  • SPARC M8-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC M7-8
SPARC M7-16
SPARC M8-8
Oracle SuperCluster M8 Hardware
Oracle SuperCluster M7 Hardware
Information in this document applies to any platform.

Purpose

 Additional Information for Event SUN4V-8002-XD

Details

Type

Hardware Fault

 (fault.io.redundancy-threshold)

Severity
    Major

Description

The number of faults on non-servicable devices has crossed the allowed threshold.

Automated Response

One or more device instances may be disabled.


Impact

System performance may be impacted

Suggested Action for System Administrator

The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)