![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2297221.1 : ILOM-8000-H0 - TLI Indeterminable
In this Document
Applies to:Sun Microsystems > Servers > x64 ServersSPARC M8-8 SPARC T8-1 SPARC T8-2 SPARC T8-4 Information in this document applies to any platform. Purpose Provide additional information for message ID: ILOM-8000-H0 DetailsTLI Indeterminable Type Alert alert.ilom.chassis.tli.invalid Severity Critical Description Message ID: ILOM-8000-H0 indicates that the ILOM fault manager has applied diagnosis to error This event occurs when either a 'Primary' quorum device is replaced or more than two quorum members are ILOM uses a quorum of three FRU's to maintain accurate key identity property information about the product. One FRU is designated a 'Primary' quorum device and two FRU's are designated 'Backup' quorum devices. When a 'Primary' quorum device is replaced, it requires authorized service personnel When two quorum devices are replaced at the same time, it requires authorized service personnel Automated Response The system is unable to determine accurate product identification and will return 'UNKNOWN' to product identification requests. Impact The system will operate in the presence of this fault. Suggested Action for System Administrator This event serves as a 'reminder' to authorized service personnel that the key identity info needs to be updated after replacing a FRU that is a quorum member. Refer to the following document for the latest procedures for displaying event content PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1 Attachments This solution has no attachment |
||||||||||||||
|