Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2296959.1
Update Date:2018-03-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2296959.1 :   ILOM-8000-JV - ILOM Filesystem Capacity Exceeded  


Related Items
  • SPARC M8-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M7-8
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC M8-8
Oracle SuperCluster M7 Hardware
SPARC M7-8
SPARC M7-16
Oracle SuperCluster M8 Hardware
Information in this document applies to any platform.

Purpose

 Provide additional information for message ID: ILOM-8000-JV

Details

ILOM Filesystem Capacity Exceeded

Type

Defect

defect.ilom.fs.full

Severity

Major

Description

Message ID: ILOM-8000-JV indicates that the ILOM fault manager has received an error report
indicating an ILOM filesystem has exceeded it's filesystem capacity limit.

If the /coredump directory is nearly full, then the core files are deleted.

If the /persist or /conf filesystem are nearly full, then temporary files are deleted to free up space in /persist.

Automated Response

The chassis wide service-required LED is illuminated.

Impact

Files are deleted.  ILOM commands may fail, especially those which make configuration changes.

Suggested Action for System Administrator

Contact Oracle Support Services if problem persist.

Refer to the following document for the latest procedures for displaying event content in preparation
for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)