Solution Type  Predictive Self-Healing Sure

Solution  2296939.1 :   ILOM-8000-KG - ILOM fault Diagnosis Exceeded  


Related Items
  • SPARC M8-8
  •  
  • SPARC M7-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Sun Microsystems > Servers > x64 Servers
SPARC M8-8
Oracle SuperCluster M8 Hardware
SPARC M7-8
SPARC M7-16
Information in this document applies to any platform.

Purpose

 Provide additional information for message ID: ILOM-8000-KG

Details

ILOM Fault Diagnosis Exceeded

Type

Defect

defect.ilom.fdd.max_faults

Severity

Major

Description

Message ID: ILOM-8000-KG indicates that the ILOM fault manager has received an error report
indicating that the ILOM fault manager has reached the diagnosis limit for a FRU.

The current limit is set to 50 faults per FRU.

Automated Response

The chassis wide and affected FRU service-required LED's are illuminated.

Impact

No future events will be diagnosed on the affected FRU until prior issues have been resolved.

Suggested Action for System Administrator

Resolve issues with the FRU that has existing faults.

If the problem continues to persist, then contact Oracle Support  Services.

Refer to the following document for the latest procedures for displaying event content in preparation
for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)