Solution Type  Predictive Self-Healing Sure

Solution  2283822.1 :   PCIEX-8001-22 - a PCI Express transmitting device sent an invalid request  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC T7-4
  •  
  • SPARC T8-2
  •  
  • SPARC T7-2
  •  
  • Solaris (SPARC)
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Sun Microsystems > Boards
Solaris (SPARC)
SPARC T7-1
SPARC T7-2
SPARC T7-4
Information in this document applies to any platform.

Purpose

Provide additional information for message ID: PCIEX-8001-22

Details

Type

Hardware Fault
   fault.io.pciex.device-invreq-noretire

Severity

Major

Description

A request from a PCI Express transmitting device is invalid

Automated Response

Details of the invalid transaction are saved to the Solaris Fault Management Architecture (FMA) fault log.

Impact

The invalid transaction is discarded.

Suggested Action for System Administrator

The recommended service action for this event is not to replace physical PCI Express hardware but to check for issues in the device firmware, system HyperVisor/firmware, Root Complex driver or leaf device driver.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
NOTE: This Message ID will not result in a service request being automatically opened via ASR