T10000D - Problems Addressed In 4.12.106 Microcode
Related Items |
- StorageTek T10000D Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Applies to:
StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Purpose
It is recommended to review the ID files and identify any drives with 100 million meters on the roller sub assembly before installing this microcode. These are the drives most likely to have a stuck roller. You may want to upgrade these drives in stages and then load an unload a tape in them if there is a large number of drives to minimize the number of down drives the customer experiences due to stuck rollers. The remaining drives that are under 100 million meters do not need to be upgraded in stages.
List the changes of problems addressed in the 4.12.106 microcode. Note - It is HIGHLY RECOMMENDED to load and unload a tape in each drive that is upgraded to these code versions before they are put into production to see if the drive has a stuck roller.
Reference KB 2251787.1 discusses 3F2E errors. This is the error you will get if the code detects a stuck roller on a drive. Once the drive posts a 3F2E error it will no longer load tapes. .
Details
Synopsis
24966446 25802210
3F2E
Changes made to detect and down any drive that has a seized or stuck roller in the tape path. Detection for this is measured and logged by the drive/s for each unload/unthread operation of each tape. T2 or T1 media,
25689579
3F21
Add a check of the shape of the pes histogram to determine if a head oscillation is indicated. If we see a high pes sigma and a head oscillation is present the drive will not be downed with a 3f21. A serious head oscillation will cause other problems which would result in the drive being replaced for perm write errors.
24764486
367B 38D2
Changes made to remove distance from Media warranty and end of life calculations along with subsequent reporting to host/applications/library etc.
24761992
3797
Fix FSC 3797 perm error running media validation on marginal tapes. This replaces special build RD411113 code.
25077718
3923
Fix FSC 3923 turning off DPKM encryption mid tape. This replaces special build RF411111 code.
25217054
None
Upgrade Dropbear security fixes since 2014.63, through 2016.74.
25429078
DCAB
Fix DCAB SNO on repeated Locate-Read with transient 37F6 read ahead errors. This replaces special build RB411113 code.
25190559
48E1
Fix FSC 48E1, while writing near the end of Marginal tapes. This replaces special build RA411113 code.
24340720
None
4.11.111 Fips Certification Fixes issue where drive does not enter Maintenance Mode if a CRC error is detected with an FPGA image in EEPROM during IPL. This replaces special build RB411111 code. Note: this was a test-only scenario and is not a functional code risk.
23520500
4074
Fix FSC 4074 trying to read un-reconstituted sparse data.
22712546
6210
Fix FSC 6210 loading a tape with un-reconstituted FSA data.
25164608
None
Save IP address change when set through the TTI interface.
25505755 25703210
31E4
Fix for 31E4 error when VSM attempts to initialize an ALP tape.