![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2251393.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.170418 (Linux - Physical) for April 2017
In this Document
Applies to:Exalogic Elastic Cloud X5-2 HardwareOracle Exalogic Elastic Cloud X2-2 Hardware Exalogic Elastic Cloud X3-2 Hardware Oracle Exalogic Elastic Cloud Software - Version 2.0.0.0.0 to 2.0.6.2.170117 Exalogic Elastic Cloud X4-2 Hardware Linux x86-64 PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around April 2017 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsNOTE:
Patch Download
Released: April 2017 Product Version: 2.0.6.2.170418 (on X2-2/X3-2/X4-2/X5-2) for Oracle Linux x86-64 PATCH 25422080 - EXALOGIC LINUX 2.0.6.2.170418 (on X2-2/X3-2/X4-2/X5-2) PATCH SET UPDATE (PSU) FOR April 2017
Patch Readme DocumentationRefer to the readme documentation attached 25422080-Linux.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 25422080-Linux.zip:
Pre-requisites If the LAG is configured on IB switches, please take a backup of /conf/lag.conf file. Once the IB Switches upgrade is completed, copy lag.conf file back on to IB switches and reboot the switches successively. INTERNAL Pre-requisites PCIe Renumbering check on ZS3-ES storage heads in Exalogic x4-2 and x5-2 racks Refer to following Note which has information on this important pre-requisite check. <Note 2087741.1>: Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks
AppendicesAppendix A: Fixed Bugs ListPlease review Document ID : 2251392.1 - Exalogic Infrastructure April 2017 PSU – Fixed Bugs List Appendix B: Patching Known IssuesPlease review Document ID : 2156050.1 - Known Issues for Exalogic 2.0.6.2.X Patch Set Updates Appendix C: Released Software and Firmware VersionsAppendix D: FAQs and Troubleshooting GuideInformation About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic PatchingPlease review Document ID : 1997466.1 - Information About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic Patching Troubleshooting GuidePlease review Document ID : 1590392.1 - Exalogic Infrastructure PSU Patching - Troubleshooting Guide References<NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note<NOTE:2156050.1> - Known Issues for Exalogic 2.0.6.2.X Patch Set Updates <NOTE:2251392.1> - Exalogic Infrastructure April 2017 PSU – Fixed Bugs List <NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||
|