Solution Type  Predictive Self-Healing Sure

Solution  2220100.1 :   SPT-8002-5H - A voltage reading on a board has been measured outside the threshold for a second time.  


Related Items
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC T7-4
Oracle SuperCluster M7 Hardware
SPARC

Purpose

 Additional Information for Message ID: SPT-8002-5H

Details

 Type

Hardware Fault 

fault.chassis.voltage.failing-nc

 

Severity

Critical

Description

           A voltage reading on a board has been measured outside the threshold for a second time.

Automated Response

          The system will be powered cycled.  The chassis-wide service required LED will be illuminated.

 

Impact

          The platform will restart with the affected component de-configured.

          If the failed component is the mother board, the system is not usable until repaired, and ILOM will not allow the system to be powered on.

 

Suggested Action for System Administrator

Event lists and/or eReports for both the temperature and voltage thresholds will not report or take any action on the upper or lower non-critical temperature thresholds, as the system will not have a chance to poll when this alarm is asserted.

By default, it will take approximately 5 seconds for accurate sensor polling.

In order to poll 3 readings: upper non-critical, upper critical and upper non-recoverable thresholds, it would take more than 30 seconds.

 

Please refer to the associated reference document for the latest service procedures and policies regarding this diagnosis.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

References

<BUG:24717350> - SYSFW: VERY HIGH SENSOR READINGS ARE STILL REPORTED AS NON-CRITICAL EREPORTS