![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2217221.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.170117 (Linux - Virtual) for January 2017
In this Document
Applies to:Exalogic Elastic Cloud X4-2 HardwareExalogic Elastic Cloud X5-2 Hardware Exalogic Elastic Cloud X3-2 Hardware Oracle Exalogic Elastic Cloud X2-2 Hardware Oracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 to 2.0.6.2.161018 Linux x86-64 Oracle Virtual Server(x86-64) PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around January 2017 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsNote:
Patch Download
Released: January 2017 Product Version: 2.0.6.2.160719 (on X2-2/X3-2/X4-2/X5-2) for Oracle Exalogic Elastic Cloud infrastructure PATCH 25095716 - EXALOGIC VIRTUAL 2.0.6.2.170117 (on X2-2/X3-2/X4-2/X5-2) PATCH SET UPDATE (PSU) FOR January 2017 Patch Readme DocumentationRefer to the readme documentation attached 25095716-Virtual.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 25095716-Virtual.zip: 25095716-Virtual
NOTE: It is the recommendation of Exalogic Development and Support that the Exalogic racks be upgraded to the latest PSU available. In particular, customers running on the January 2017 PSU are strongly recommended to take advantage of the issues addressed in later PSU's. If, for some reason, it is not possible to follow this best practice and a rack needs to stay on the January 2017 PSU release, the EMOC Cumulative Patch 25919962 mentioned in "POST PATCH RECOMMENDATION" section below should be applied as a priority, once a backup has been taken. POST PATCH RECOMMENDATIONIn Exalogic racks running January 2017 Virtual (EECS 2.0.6.2.170117), a few incidents have been reported of observing "Algorithm negotiation fail" errors in EMOC cacao logs resulting in the inability to start guest vServers from EMOC. The discovery of Compute Nodes ILOMs from EMOC also fails. Refer to the following MOS Note for details: <Note 2271847.1>: Unable to Start Guest vServers From EMOC BUI In Exalogic January 2017 PSU 2.0.6.2.170117 Virtual Rack.
As a proactive measure, we recommend applying the EMOC Cumulative Patch mentioned in above note following the upgrade of the rack to January 2017 PSU.
Prerequisite Important: Before patching, verify that the cluster heartbeat timeout is set correctly, as documented in the Document ID : 1995593.1 - Increase O2CB Cluster Heartbeat Timeout on Exalogic Virtual
INTERNAL Pre-requisites PCIe Renumbering check on ZS3-ES storage heads in Exalogic x4-2 and x5-2 racks Refer to following Note which has information on this important pre-requisite check. <Note 2087741.1>: Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks
AppendicesAppendix A: Fixed Bugs ListPlease review Document ID : 2217232.1 - Exalogic Infrastructure January 2017 PSU – Fixed Bugs List Appendix B: Patching Known IssuesPlease review Document ID : 2156050.1 - Known Issues for Exalogic 2.0.6.2.X Patch Set Updates Appendix C: Released Software and Firmware VersionsAppendix D: FAQs and Troubleshooting GuideInformation About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic PatchingPlease review Document ID : 1997466.1 - Information About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic Patching Guest vServer patching FAQ'sPlease review Document ID : 2031749.1 - FAQs Regarding vServer Patching Part Of Exalogic PSU Upgrade Troubleshooting GuidePlease review Document ID : 1590392.1 - Exalogic Infrastructure PSU Patching - Troubleshooting Guide
References<NOTE:2156050.1> - Known Issues for Exalogic 2.0.6.2.X Patch Set Updates<NOTE:2217232.1> - Exalogic Infrastructure January 2017 PSU – Fixed Bugs List <NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues <NOTE:2271847.1> - Unable to Start Guest vServers From EMOC BUI In Exalogic January 2017 PSU 2.0.6.2.170117 Virtual Rack <NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||
|