![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2213190.1 : SPARC M8 and SPARC M7 Series Servers : PDECB reported as disabled in the prtdiag output
In this Document
Applies to:SPARC M8-8 - Version All Versions and laterOracle SuperCluster M7 Hardware - Version All Versions and later SPARC M7-16 - Version All Versions and later SPARC M7-8 - Version All Versions and later Information in this document applies to any platform. PurposeThe "Environmental Status" section of the 'prtdiag -v' output from the control domain reports some PDECB sensors as "disabled". For instance, from Host1 from a M7-8 server with 2 pdomains : host1:~# prtdiag -v ... ============================ Environmental Status ============================ ... Current sensors: ... SYS/PDECB3/ECB I_OUT disabled
DetailsThis is expected when no CMIOU is installed in the slot; so the respective PDECB (Power distribution electronic circuit breaker) sensors are disabled. There is one PDECB for each CMIOU. All of the PDECBs are present even if there is no CMIOU installed. The PDECB is a separate component. Unless there is FMA event/log indicating a fault on the PDECB, there is no action needed.
From Host1 from a M7-8 server with 2 pdomains. Only some CMIOUs are installed : -> show -d target /Servers/PDomains/PDomain_0/System/DCUs/DCU_0 /Servers/PDomains/PDomain_0/System/DCUs/DCU_0 -> show -d target /Servers/PDomains/PDomain_1/System/DCUs/DCU_1 /Servers/PDomains/PDomain_1/System/DCUs/DCU_1 As a result, from the 'prtdiag -v' output : # prtdiag -v | grep PDECB
... SYS/PDECB3/ECB I_OUT disabled SYS/PDECB0/ECB I_OUT ok SYS/PDECB5/ECB I_OUT ok SYS/PDECB7/ECB I_OUT disabled SYS/PDECB2/ECB I_OUT ok SYS/PDECB4/ECB I_OUT ok SYS/PDECB6/ECB I_OUT disabled SYS/PDECB1/ECB I_OUT ok SYS/PDECB3/ECB V_OUT disabled SYS/PDECB0/ECB V_OUT ok SYS/PDECB5/ECB V_OUT ok SYS/PDECB7/ECB V_OUT disabled SYS/PDECB2/ECB V_OUT ok SYS/PDECB4/ECB V_OUT ok SYS/PDECB6/ECB V_OUT disabled SYS/PDECB1/ECB V_OUT ok All of the PDECB sensors for the not-installed CMIOUs are reported as Disabled. From ILOM : -> show /SYS/PDECB3/ECB/V_OUT /SYS/PDECB3/ECB/V_OUT Properties: -> show /SYS/PDECB2/ECB/V_OUT /SYS/PDECB2/ECB/V_OUT Properties:
Attachments This solution has no attachment |
||||||||||||||
|