Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2194957.1
Update Date:2016-11-23
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2194957.1 :   SPSUN4V-8002-QJ - An uncorrectable DIMM error has occurred.  


Related Items
  • SPARC M7-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC T7-4
  •  
  • SPARC T7-2
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: M7
  •  




In this Document
Purpose
Scope
Details
References


Applies to:

SPARC M7-8
SPARC M7-16
Oracle SuperCluster M7 Hardware
SPARC T7-1
SPARC T7-4
Information in this document applies to any platform.

Purpose

 Additional information for Message ID: SPSUN4V-8002-QJ

Scope

 Additional information for Message ID: SPSUN4V-8002-QJ

Details

 TYPE: Fault.

     fault.memory.dimm-ue-spare

Severity: Minor

Description:

An uncorrectable error has occurred in a DIMM.

Automated Response:

The DIMM causing the fault will be isolated on the next system restart.

Impact:

Some services may be lost with a negligible impact to system performance.

Suggested Action for System Administrator:

There is no action necessary by the System Administrator. This is a non serviceable fault, which will not generate a Service Request (SR). However, if for some reason you fine it necessary, refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.