![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2187177.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.161018 (Linux - Virtual) for October 2016
In this Document
Applies to:Exalogic Elastic Cloud X3-2 HardwareOracle Exalogic Elastic Cloud X2-2 Hardware Oracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 to 2.0.6.2.160719 Exalogic Elastic Cloud X4-2 Hardware Exalogic Elastic Cloud X5-2 Hardware Linux x86-64 Oracle Virtual Server(x86-64) PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around October 2016 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsNote:
Patch Download
Released: October 2016 Product Version: 2.0.6.2.160719 (on X2-2/X3-2/X4-2/X5-2) for Oracle Exalogic Elastic Cloud infrastructure PATCH 24375265 - EXALOGIC VIRTUAL 2.0.6.2.161018 (on X2-2/X3-2/X4-2/X5-2) PATCH SET UPDATE (PSU) FOR OCTOBER 2016 Patch Readme DocumentationRefer to the readme documentation attached 24375265-Virtual.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 24375265-Virtual.zip: 24375265-Virtual
Prerequisite Important: Before patching, verify that the cluster heartbeat timeout is set correctly, as documented in the Document ID : 1995593.1 - Increase O2CB Cluster Heartbeat Timeout on Exalogic Virtual
INTERNAL Pre-requisites PCIe Renumbering check on ZS3-ES storage heads in Exalogic x4-2 and x5-2 racks Refer to following Note which has information on this important pre-requisite check. <Note 2087741.1>: Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks
AppendicesAppendix A: Fixed Bugs ListPlease review Document ID : 2187178.1 - Exalogic Infrastructure October 2016 PSU – Fixed Bugs List Appendix B: Patching Known IssuesPlease review Document ID : 2156050.1 - Known Issues for Exalogic 2.0.6.2.X Patch Set Updates Appendix C: Released Software and Firmware VersionsAppendix D: FAQs and Troubleshooting GuideInformation About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic PatchingPlease review Document ID : 1997466.1 - Information About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic Patching Guest vServer patching FAQ'sPlease review Document ID : 2031749.1 - FAQs Regarding vServer Patching Part Of Exalogic PSU Upgrade Troubleshooting GuidePlease review Document ID : 1590392.1 - Exalogic Infrastructure PSU Patching - Troubleshooting Guide
References<NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note<NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues <NOTE:2187178.1> - Exalogic Infrastructure October 2016 PSU – Fixed Bugs List <NOTE:2188815.1> - Exalogic NM2-GW Switch Upgrade Guide from v2.0.x to v2.1.6-2 <NOTE:2156050.1> - Known Issues for Exalogic 2.0.6.2.X Patch Set Updates <NOTE:2197121.1> - FAQ: Is LDAP Authentication In Exalogic Infiniband Switch's ILOM Available ? Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||
|