![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2178773.1 : IBSWITCH-8000-77 - Ambient temperature exceeds threshold limit.
In this Document
Applies to:Oracle InfiniBand Switch IS2-46Information in this document applies to any platform. PurposeProvide additional information for message ID: IBSWITCH-8000-77 DetailsAmbient temperature exceeds threshold limit. Type Fault Severity Major Description The ambient temperature is at or above the normal temperature threshold. Automated Response Illuminate service-required LED on the chassis. Impact The system continues to operate provided the internal temperature range does not exceed threshold for adequate cooling. Suggested Action for System Administrator Please verify the fan modules are operating normal. Ensure that there is sufficient airflow to the location of the switch. Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1) Attachments This solution has no attachment |
||||||||||||||||
|