![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2171358.1 : SuperCluster: Oracle SuperCluster M7 Check and Remediation for ZS3-ES 2nd Head Cache Device
Some M7 SuperClusters were shipped without the cache device set-up correctly on the 2nd head of the ZS3-ES storage. This article describes how to check for, and if necessary, remediate the issue. Applies to:Oracle SuperCluster M7 Hardware - Version All Versions and laterInformation in this document applies to any platform. PurposeSome Oracle SuperCluster M7 systems were shipped without the cache device set-up correctly on the 2nd head of the ZS3-ES storage. This article describes how to check for and remediate the issue. DetailsLog into head 2 of the ZS3-ES and Verify the ZS3-ES is clustered using the example syntax below. orlm7sn2:> configuration cluster get state
state = AKCS_CLUSTERED If the ZS3-ES is not in this state then failback will need to be performed from both heads until AKCS_CLUSTER
orlm7sn2:> configuration storage
If you do not get the prompt $hostname:configuration storage (supercluster2)> then your storage is misconfigured in an unexpected way and you should seek further guidance by raising a Service Request with Oracle Support. If it is fine do the following set 0-cache=2
done set cache_profile=cache_stripe done
<wait> When the prompt returns you may run "get cache_profile" to verify "cache_stripe" is set correctly & log out. The above method was tested by Keith Bond on SuperCluster M7 in collaboration with the RPE ZFSSA team Attachments This solution has no attachment |
||||||||||||
|