Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2156070.1
Update Date:2017-10-11
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2156070.1 :   Device Paths for the Netra SPARC S7-2  


Related Items
  • Netra SPARC S7-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: S7
  •  




Applies to:

Netra SPARC S7-2
Information in this document applies to any platform.

Purpose

 This document lists the device paths for the Netra SPARC S7-2.

Details

 The dual processor Netra S7-2 device paths are:

Device NAC Name  Description  Device Path  Switch #  Phys Port  Device # Owner  Width 
/SYS/MB/USB_CTLR USB Host Controller /pci@300/pci@1/pci@0/pci@2/usb@0 PCIE 0 Port 8 pci@2 CPU0 x1
/SYS/MB/XGBE Fortville Ethernet Controller /pci@300/pci@1/pci@0/pci@1 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET0 Fortville NET 0 /pci@300/pci@1/pci@0/pci@1/network@0 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET1 Fortville NET 1 /pci@300/pci@1/pci@0/pci@1/network@0,1 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET2 Fortville NET 2 /pci@300/pci@1/pci@0/pci@1/network@0,2 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET3 Fortville NET 3 /pci@300/pci@1/pci@0/pci@1/network@0,3 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/PCIE1 PCIE SLOT1 /pci@300/pci@1/pci@0/pci@a PCIE 0 Port 10 pci@a CPU0 x8 (Phys x16)
/SYS/MB/PCIE2 PCIE SLOT2 /pci@300/pci@1/pci@0/pci@11 PCIE 0 Port 4 pci@11 CPU0 x8
/SYS/MB/PCIE3 PCIE SLOT3 /pci@302/pci@1/pci@0/pci@12 PCIE 0 Port 6 pci@12 CPU1 x8
/SYS/MB/PCIE4 PCIE SLOT4 /pci@302/pci@1/pci@0/pci@13 PCIE 0 Port 12 pci@13 CPU1 x8
/SYS/MB/PCIE5 PCIE SLOT5 /pci@300/pci@2/pci@0/pci@14 PCIE 1 Port 4 pci@14 CPU0 x8 (Phys x16)
/SYS/MB/PCIE6 PCIE SLOT6 /pci@302/pci@2/pci@0/pci@15 PCIE 1 Port 6 pci@15 CPU1 x8
/SYS/MB/PCIE7 INTERNAL SAS SLOT /pci@302/pci@2/pci@0/pci@6 PCIE 1 Port 10 pci@6 CPU1 x8
/SYS/DBP/NVME0 NVME Drive in Disk Slot 0 /pci@300/pci@2/pci@0/pci@18/nvme@0/disk@1 PCIE 1 Port 14 pci@18 CPU0 x4
/SYS/DBP/NVME1 NVME Drive in Disk Slot 1 /pci@302/pci@2/pci@0/pci@19/nvme@0/disk@1 PCIE 1 Port 15 pci@19 CPU1 x4
/SYS/DBP/NVME2 NVME Drive in Disk Slot 2 /pci@302/pci@2/pci@0/pci@17/nvme@0/disk@1 PCIE 1 Port 13 pci@17 CPU1 x4
/SYS/DBP/NVME3 NVME Drive in Disk Slot 3 /pci@300/pci@2/pci@0/pci@16/nvme@0/disk@1 PCIE 1 Port 12 pci@16 CPU0 x4
/SYS/DBP/HDD0 SAS/SATA Drive in Slot 0 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p2 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD1 SAS/SATA Drive in Slot 1 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p3 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD2 SAS/SATA Drive in Slot 2 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p1 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD3 SAS/SATA Drive in Slot 3 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p0 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD4 SAS/SATA Drive in Slot 4 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p6 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD5 SAS/SATA Drive in Slot 5 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p7 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD6 SAS/SATA Drive in Slot 6 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p5 PCIE 1 Port 6 pci@6 CPU1 -
/SYS/DBP/HDD7 SAS/SATA Drive in Slot 7 /pci@302/pci@2/pci@0/pci@6/LSI,sas@0/disk@p4 PCIE 1 Port 6 pci@6 CPU1 -


The single processor Netra S7-2  device paths are:

Device NAC Name  Description  Device Path  Switch #  Phys Port  Device # Owner  Width 
/SYS/MB/USB_CTLR USB Host Controller /pci@300/pci@1/pci@0/pci@2/usb@0 PCIE 0 Port 8 pci@2 CPU0 x1
/SYS/MB/XGBE Fortville Ethernet Controller /pci@300/pci@1/pci@0/pci@1 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET0 Fortville NET 0 /pci@300/pci@1/pci@0/pci@1/network@0 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET1 Fortville NET 1 /pci@300/pci@1/pci@0/pci@1/network@0,1 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET2 Fortville NET 2 /pci@300/pci@1/pci@0/pci@1/network@0,2 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/NET3 Fortville NET 3 /pci@300/pci@1/pci@0/pci@1/network@0,3 PCIE 0 Port 14 pci@1 CPU0 x8
/SYS/MB/PCIE1 PCIE SLOT1 /pci@300/pci@1/pci@0/pci@a PCIE 0 Port 10 pci@a CPU0 x8 (Phys x16)
/SYS/MB/PCIE2 PCIE SLOT2 /pci@300/pci@1/pci@0/pci@11 PCIE 0 Port 4 pci@11 CPU0 x8
/SYS/MB/PCIE3 PCIE SLOT3 /pci@300/pci@1/pci@0/pci@12 PCIE 0 Port 6 pci@12 CPU0 x8
/SYS/MB/PCIE4 PCIE SLOT4 /pci@300/pci@1/pci@0/pci@13 PCIE 0 Port 12 pci@13 CPU0 x8
/SYS/MB/PCIE5 PCIE SLOT5 /pci@300/pci@2/pci@0/pci@14 PCIE 1 Port 4 pci@14 CPU0 x8 (Phys x16)
/SYS/MB/PCIE6 PCIE SLOT6 /pci@300/pci@2/pci@0/pci@15 PCIE 1 Port 6 pci@15 CPU0 x8
/SYS/MB/PCIE7 INTERNAL SAS SLOT /pci@300/pci@2/pci@0/pci@6 PCIE 1 Port 10 pci@6 CPU0 x8
/SYS/DBP/NVME0 NVME Drive in Disk Slot 0 /pci@300/pci@2/pci@0/pci@18/nvme@0/disk@1 PCIE 1 Port 14 pci@18 CPU0 x4
/SYS/DBP/NVME1 NVME Drive in Disk Slot 1 /pci@300/pci@2/pci@0/pci@19/nvme@0/disk@1 PCIE 1 Port 15 pci@19 CPU0 x4
/SYS/DBP/NVME2 NVME Drive in Disk Slot 2 /pci@300/pci@2/pci@0/pci@17/nvme@0/disk@1 PCIE 1 Port 13 pci@17 CPU0 x4
/SYS/DBP/NVME3 NVME Drive in Disk Slot 3 /pci@300/pci@2/pci@0/pci@16/nvme@0/disk@1 PCIE 1 Port 12 pci@16 CPU0 x4
/SYS/DBP/HDD0 SAS/SATA Drive in Slot 0 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p2 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD1 SAS/SATA Drive in Slot 1 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p3 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD2 SAS/SATA Drive in Slot 2 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p1 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD3 SAS/SATA Drive in Slot 3 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p0 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD4 SAS/SATA Drive in Slot 4 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p6 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD5 SAS/SATA Drive in Slot 5 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p7 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD6 SAS/SATA Drive in Slot 6 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p5 PCIE 1 Port 6 pci@6 CPU0 -
/SYS/DBP/HDD7 SAS/SATA Drive in Slot 7 /pci@300/pci@2/pci@0/pci@6/LSI,sas@0/disk@p4 PCIE 1 Port 6 pci@6 CPU0 -

Attachments
This solution has no attachment