Asset ID: |
1-79-2151267.1 |
Update Date: | 2016-08-03 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2151267.1
:
SuperCluster Supported Software Versions For 2.x Install Bundles
Related Items |
- Oracle SuperCluster M7 Hardware
- Oracle SuperCluster T5-8 Hardware
- Solaris Operating System
- Oracle SuperCluster M6-32 Hardware
- Oracle Exadata Storage Server Software
- Oracle SuperCluster T5-8 Half Rack
- Oracle SuperCluster T5-8 Full Rack
|
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
|
SuperCluster Supported Software Versions For 2.x Builds. These can occasionally have difference form the most recently released Quarterly Full Stack Download Patch. These stacks are considered supported versions up until the next Quarterly Full Stack Download Patch in which case the system should be patched up to the Quarterly Full Stack Download Patch level.
Applies to:
Oracle SuperCluster T5-8 Hardware
Oracle SuperCluster T5-8 Half Rack
Solaris Operating System
Oracle SuperCluster T5-8 Full Rack
Oracle SuperCluster M6-32 Hardware
Oracle Solaris on SPARC (64-bit)
Oracle SuperCluster Supported Software Versions For 2.x Builds. These can occasionally have difference form the most recently released Quarterly Full Stack Download Patch. These stacks are considered supported versions up until the next Quarterly Full Stack Download Patch in which case the system should be patched up to the Quarterly Full Stack Download Patch level.
Purpose
Oracle SuperCluster Supported Software Versions For 2.x Builds. These can occasionally have difference form the most recently released Quarterly Full Stack Download Patch. These stacks are considered supported versions up until the next Quarterly Full Stack Download Patch in which case the system should be patched up to the Quarterly Full Stack Download Patch level. Refer to <Document 2056975.1> - Contents of each SuperCluster Quarterly Full Stack Download Patch (QFSDP)
To determine your build version run:
root@orlm7db01:~# svcprop -p configuration/build oes/id
ssc-2.1.7
Scope
Oracle SuperCluster 2,x builds that have not been brought up to the latest Quarterly Full Stack Download Patch
Details
Individual Component versions contained in the Initial Release Oracle SuperCluster V2.x Systems
Component | Latest Release |
Exadata Storage Server
Note: All system firmware and software is automatically maintained by the Exadata software, unless otherwise indicated. Do NOT manually update firmware or software unless directed by Oracle Support.
|
Exadata Storage Server 12c Ex adata Storage Server software 12.1.2.1.0 (Note 1947476.1) Recommended to use Exadata 12c with Database 12c
Please note it is supported to run the cells in a V2.0 build at 12.1.2.1.2
|
Database Server
Note: Oracle Server software patches in addition to those listed may be applied as required. If OPatch reports a conflict with one or more patches in this list, you should not force apply your patch. Contact Oracle Support for assistance to resolve the patch conflict
|
Oracle Database 12c Release 1 (12.1.0.2) Patch Set 1
12.1.0.2.160119 (Jan 2016) Database Patch for Engineered Systems and Database In-Memory patch 22243551
Oracle Database 11g Release 2 (11.2.0.4) Patch Set 3
11.2.0.4.160119 Database Patch for Exadata (Jan 2016) patch 22320025
Please note it is supported to bring the DB bundle patch level to the latest released on SPARC in a V2.0 build
|
T5-8 Firmware
|
9.5.1.b
|
M6-32 Firmware
|
9.5.1.b
|
Solaris 11.3 OS
The SuperClusters are tested and certified at certain SRU and Jumbo IDR levels. It is not allowable to send a SuperCluster LDom past the latest certified and tested SRU level . Individual IDRs will have to be backported to the customer SRU level and can be applied as long as they do not conflict with the existing Jumbo IDR for that SRU. If it does conflict then it will have to be merged into the Jumbo IDR for that release. If the customer needs to get to the latest certified SRU level it is strongly recommended that they do so v ia the latest QFSDP. Exceptions will have to be worked out between Oracle Support and SuperCluster Engineering.
|
Find latest at SuperCluster Recommended IDR + CVE <Doc 2086278.1>
Solaris Cluster 4.3.1.2
|
Solaris 10 OS
|
Oracle Solaris Cluster 3.3u2 Patch Train #9
|
Oracle Exafamily Update
|
|
InfiniBand Switch
Note: InfiniBand switch software updates are delivered as part of the Quarterly Full Stack Download Patches. Do NOT apply InfiniBand switch software updates obtained from other sources unless directed by Oracle Support.
|
Exadata Database Machine - Sun Datacenter InfiniBand Switch 36 Switch software version 2.1.5-1 (supplied with Exadata 12.1.2.2.1)
Switch software version 2.1.5-1(supplied with Exadata 12.1.2.1.3)
|
ZFS Storage Appliance ZS3-ES Software |
ZFS Storage Appliance Software 2013.1.4.8
|
ZFS Storage Appliance ZS3-ES Firmware |
No Longer Included |
PDU |
SunRack II PDU Metering Unit Firmware - updates the Sun Rack II PDU Metering Unit Firmware (1.06) |
Individual Component versions contained in the Initial Release Oracle SuperCluster V2.1 Systems Oracle SuperCluster M7 only
Component | Latest Release |
Exadata Storage Server
Note: All system firmware and software is automatically maintained by the Exadata software, unless otherwise indicated. Do NOT manually update firmware or software unless directed by Oracle Support.
|
Exadata Storage Server 12c
Recommended to use Exadata 12c with Database 12c
Exadata Storage Server software 12.1.2.1.3 patch 21446295
|
Database Server
Note: Oracle Server software patches in addition to those listed may be applied as required. If OPatch reports a conflict with one or more patches in this list, you should not force apply your patch. Contact Oracle Support for assistance to resolve the patch conflict
|
Oracle Database 12c Release 1 (12.1.0.2) Patch Set 1
12.1.0.2.160119 (Jan 2016) Database Patch for Engineered Systems and Database In-Memory patch 22243551
Oracle Database 11g Release 2 (11.2.0.4) Patch Set 3
11.2.0.4.160119 Database Patch for Exadata (Jan 2016) patch 22320025
|
|
|
|
|
Solaris 11.3 OS
The SuperClusters are tested and certified at certain SRU and Jumbo IDR levels. It is not allowable to send a SuperCluster LDom past the latest certified and tested SRU level . Individual IDRs will have to be backported to the customer SRU level and can be applied as long as they do not conflict with the existing Jumbo IDR for that SRU. If it does conflict then it will have to be merged into the Jumbo IDR for that release. If the customer needs to get to the latest certified SRU level it is strongly recommended that they do so via the latest QFSDP. E xceptions will have to be worked out between Oracle Support and SuperCluster Engineering.
|
Find latest at SuperCluster Recommended IDR + CVE <Doc 2086278.1>
Solaris Cluster 4.3.1.2
|
Solaris 10 OS
|
Oracle Solaris Cluster 3.3u2 patch train set #9
|
Oracle Exafamily Update
|
2.1.0.800 |
InfiniBand Switch
Note: InfiniBand switch software updates are delivered as part of the Quarterly Full Stack Download Patches. Do NOT apply InfiniBand switch software updates obtained from other sources unless directed by Oracle Support.
|
Exadata Database Machine - Sun Datacenter InfiniBand Switch 36 Switch software version 2.1.8-1 patch 22173626
|
ZFS Storage Appliance ZS3-ES Software |
ZFS Storage Appliance Software 2013.1.4.8
|
ZFS Storage Appliance ZS3-ES Firmware |
ZFS-ES X3-2 (X4170 M3) ILOM/BIOS FW 1.2.0 (verify)
|
PDU |
SunRack II PDU Metering Unit Firmware - updates the Sun Rack II PDU Metering Unit Firmware (1.06) |
Community Discussions
Still have questions? Use the communities window below to search for similar discussions or start a new discussion on this subject. (Window is the live community not a screenshot)
Click here to open in main browser window
References
<NOTE:2056975.1> - Contents of each SuperCluster Quarterly Full Stack Download Patch (QFSDP)
<NOTE:888828.1> - Exadata Database Machine and Exadata Storage Server Supported Versions
<NOTE:2086278.1> - SuperCluster Recommended IDRs and CVEs Addressed
<NOTE:1452277.1> - SuperCluster Critical Issues
Attachments
This solution has no attachment