SL3000 - Missing AEM Error Codes

Details

The SL3000 AEM result codes were never added to the SL3000 error code dictionary €œ(xxx.ElibCode.dictionary) that is included with all code releases. Below is a list of the missing codes. These will be added to future code release packages.

 

3001=RESULT_CODE_MOTOR_FAILURE

"Motor Failure"

3002=RESULT_CODE_MOTOR_STALL

"Motor Stalled"

3003=RESULT_CODE_SWITCH_FAILURE

"Switch Failure"

3004=RESULT_MECHANICAL_FAILURE

"Mechanical failure"

3005=RESULT_CODE_INVALID_REQUEST

"Invalid Request"

3006=RESULT_CODE_STATE_NOT_READY

"Mechanism state was not ready, cannot begin move"

3007=RESULT_CODE_DEADBOLT_MOVE_FAILED

"Deadbolt cannot move"

3008=RESULT_CODE_FPGA_LIB_FAILURE

"FPGA library failure"

3009=RESULT_CODE_MOTOR_BUSY

"Motor(s) busy"

3010=RESULT_CODE_MOTOR_TIMEOUT

"Motor timed out during move"

 

4.32 example………

2016-05-19T02:11:37.297, 1.1.31.0.0, root, default, internal, 0,

error, 3955, "Error from device Code: 302 - AEM move failed ok to retry",

Data=<response sequence="1636"

final="true"><command>moveToPosition</command><result

identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode

>3002</resultCode><resultText><!|CDATA|Move failed, OK to try again - Motor

Stalled : safety door motor

event||></resultText><operationalState>302</operationalState></resultStatus></

result></response>

.

2016-05-19T02:11:38.908, 1.1.31.0.0, root, default, internal, 0,

error, 3955, "Error from device Code: 301 - AEM move failed", Data=<response

sequence="1637" final="true"><command>moveToPosition</command><result

identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode

>3001</resultCode><resultText><!|CDATA|Move failed, cannot move - Motor

Failure : safety door motor event : encoder phase err

(PHASE_ERR)||></resultText><operationalState>301</operationalState></resultSta

tus></result></response>