![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2129037.1 : SPT-8002-MY - a low ambient temperature threshold has been exceeded
In this Document
Applies to:ILOM (Integrated Lights Out Management)SPARC S7-2 SPARC S7-2L Netra SPARC S7-2 MiniCluster S7-2 Hardware SPARC PurposeProvide additional information for message ID: SPT-8002-MY DetailsType: Alert alert.ilom.temp.external.under.critical Severity: Critical Description: An ambient temperature sensor has exceeded a low temperature threshold. Automated Response: The system will perform a non-graceful shutdown. Impact: The system will not power on until the low temperature fault is manually cleared and the ambient temperature has returned to normal. Suggested Action for System Administrators: This event is essentially informational in nature and may not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response.