Solution Type Predictive Self-Healing Sure Solution 2128566.1 : SPT-8002-GE - an ambient temperature threshold has been exceeded
In this Document
Applies to:SPARC S7-2LNetra SPARC S7-2 MiniCluster S7-2 Hardware ILOM (Integrated Lights Out Management) SPARC S7-2 SPARC PurposeProvide additional information for message ID: SPT-8002-GE DetailsType: Alert alert.ilom.temp.external.over.minor Severity: Minor Description: An ambient temperature sensor has exceeded the high temperature warning threshold for more than two minutes. Automated Response: When the ambient temperature falls below the threshold value the condition will self-clear. Impact: System performance may be affected until the ambient temperature falls sufficiently to clear the condition. Suggested Action for System Administrators: This event is essentially informational in nature and may not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response.